Skip to content
DraconiticResearch
Search Sources API
181,716 studies31 sourcesUpdated 59 min ago
Peer-reviewedCC BY陆军军医大学学报

Lightweight multimodal brain tumor MRI segmentation network for efficient clinical deployment: MLG-UNet achieves an average Dice of 86.67% with 0.81 M parameters

  1. 1School of Computer Science and Software Engineering, Southwest Petroleum University, Chengdu, Sichuan
  2. 2Sichuan Provincial Key Laboratory of Nuclear Medicine and Radiation Safety, North Sichuan Medical College, Nanchong, Sichuan
  3. 3Department of Radiology, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, China

Abstract

Objective To address the problems of high model redundancy, high inference latency, and high computational resource demands faced by brain tumor MRI segmentation models when deployed in radiology departments and clinical settings, this study explores methods to maintain high segmentation accuracy while minimizing model parameters and computational overhead as much as possible, so as to meet the needs of efficient assisted analysis on general clinical terminals and resource-constrained devices. Methods Based on the BraTS2020 and BraTS2019 datasets from the international multimodal Brain Tumor Segmentation (BraTS) challenge, only the official training cases were used and divided at the patient level into training sets (BraTS2020: 277 cases; BraTS2019: 251 cases), validation sets (BraTS2020: 37 cases; BraTS2019: 34 cases), and test sets (BraTS2020: 55 cases; BraTS2019: 50 cases), after which 2D axial slices were extracted. A lightweight multimodal brain tumor MRI segmentation model, termed MLG-UNet, was proposed, which adopted a shared encoder-decoder architecture and incorporates 3 designed modules: branch-context multi-kernel block (BCMB), low-rank bilinear fusion module (LRBF), and lightweight global bottleneck modulator (LGBM), which enhance multi-scale feature extraction, cross-layer feature interaction, and high-level semantic modeling, respectively. The model was compared with representative methods, including U-Net, TransUNet, UNeXt, EMCAD, Swin-Unet, and model performance and stability were comprehensively evaluated through ablation experiments, visualization analysis, and patient-level five-round repeated holdout validation. Results On the BraTS2020 test set, MLG-UNet achieved a mean Dice of 86.67% and a mean 95th-percentile Hausdorff distance (HD95) of 3.61 mm with only 0.81 M parameters and 0.53 G floating-point operations (FLOPs), and its mean metrics were superior to all compared methods. The Dice values for the whole tumor (WT), tumor core (TC), and enhancing tumor (ET) subregions reached 91.50%, 88.82%, and 79.70%, with corresponding HD95 values of 3.37, 3.58, and 3.89 mm, respectively. Compared with TransUNet, which achieved the second-best mean Dice, MLG-UNet improved the mean Dice by 0.49 percentage points, while reducing the parameters from 105.17 M to 0.81 M. Compared with the lightweight method UNeXt, MLG-UNet improved the mean Dice by 0.69 percentage points and reduced the mean HD95 by 0.38 mm, with lower parameter count and computational complexity. On the BraTS2019 test set, the mean Dice was 86.51% and the mean HD95 was 3.68 mm, also outperforming all compared methods, demonstrating favorable cross-dataset generalization. Ablation experiments showed that BCMB, LRBF, and LGBM all effectively improved segmentation performance. Visual comparison demonstrated higher agreement between the segmentation results of the proposed method and expert annotations. In patient-level five-round repeated holdout validation, the mean Dice was (86.71±0.52)% and the mean HD95 was (3.65±0.14) mm, indicating high stability. Conclusion MLG-UNet achieved a mean Dice of 86.67%, with only 0.81 M parameters, maintaining high brain tumor MRI segmentation accuracy while controlling model size and computational overhead, and exhibits stable segmentation performance across different patient partitions.

Related

  1. Efficient and real-time polyp segmentation: An empirical evaluation of lightweight Mamba integration strategies
    Si Chen, Mohd Shafry Mohd Rahim, Hiew Moi Sim +4
    PLOS OnePeer-reviewedCC BY 4.0Full textHydrology & soilsOncologyPLOS
  2. Lightweight multi-task network for synchronous fatigue detection and ankle instability gait analysis in football training with edge deployment
    Zou Maoning
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  3. Feature-aware attention convolutional neural network for efficient pulmonary fibrosis classification from chest CT images with FPGA deployment
    K. Mahapackialakshmi, G. Jaffino
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Structure-preserving lightweight skin lesion segmentation with dual-resolution attention and boundary-aware fusion
    Xu Yang, Duwei Dai, Caixia Dong +2
    Digital HealthPeer-reviewedCC BYFull textOncologyDOAJ
  5. AMF-U-Net: an adaptive multimodal fusion residual attention 3D U-Net for boundary-aware brain tumour segmentation
    A. Anushya, Rasha Almarshdi, Bedour Alrashidi +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textNeurologyCrossref
BibTeX
@article{xingpeng2026lightweight,
  title = {{Lightweight multimodal brain tumor MRI segmentation network for efficient clinical deployment: MLG-UNet achieves an average Dice of 86.67% with 0.81 M parameters}},
  author = {Zhang Xingpeng and Zhang Xingpeng and Wang Qiuli},
  journal = {陆军军医大学学报},
  year = {2026},
  month = oct,
  doi = {10.16016/j.2097-0927.202606058},
  url = {https://doi.org/10.16016/j.2097-0927.202606058},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Lightweight multimodal brain tumor MRI segmentation network for efficient clinical deployment: MLG-UNet achieves an average Dice of 86.67% with 0.81 M parameters
AU  - Zhang Xingpeng
AU  - Zhang Xingpeng
AU  - Wang Qiuli
PY  - 2026
DA  - 2026/10/30
JO  - 陆军军医大学学报
DO  - 10.16016/j.2097-0927.202606058
UR  - https://doi.org/10.16016/j.2097-0927.202606058
AB  - Objective To address the problems of high model redundancy, high inference latency, and high computational resource demands faced by brain tumor MRI segmentation models when deployed in radiology departments and clinical settings, this study explores methods to maintain high segmentation accuracy while minimizing model parameters and computational overhead as much as possible, so as to meet the needs of efficient assisted analysis on general clinical terminals and resource-constrained devices. Methods Based on the BraTS2020 and BraTS2019 datasets from the international multimodal Brain Tumor Segmentation (BraTS) challenge, only the official training cases were used and divided at the patient level into training sets (BraTS2020: 277 cases; BraTS2019: 251 cases), validation sets (BraTS2020: 37 cases; BraTS2019: 34 cases), and test sets (BraTS2020: 55 cases; BraTS2019: 50 cases), after which 2D axial slices were extracted. A lightweight multimodal brain tumor MRI segmentation model, termed MLG-UNet, was proposed, which adopted a shared encoder-decoder architecture and incorporates 3 designed modules: branch-context multi-kernel block (BCMB), low-rank bilinear fusion module (LRBF), and lightweight global bottleneck modulator (LGBM), which enhance multi-scale feature extraction, cross-layer feature interaction, and high-level semantic modeling, respectively. The model was compared with representative methods, including U-Net, TransUNet, UNeXt, EMCAD, Swin-Unet, and model performance and stability were comprehensively evaluated through ablation experiments, visualization analysis, and patient-level five-round repeated holdout validation. Results On the BraTS2020 test set, MLG-UNet achieved a mean Dice of 86.67% and a mean 95th-percentile Hausdorff distance (HD95) of 3.61 mm with only 0.81 M parameters and 0.53 G floating-point operations (FLOPs), and its mean metrics were superior to all compared methods. The Dice values for the whole tumor (WT), tumor core (TC), and enhancing tumor (ET) subregions reached 91.50%, 88.82%, and 79.70%, with corresponding HD95 values of 3.37, 3.58, and 3.89 mm, respectively. Compared with TransUNet, which achieved the second-best mean Dice, MLG-UNet improved the mean Dice by 0.49 percentage points, while reducing the parameters from 105.17 M to 0.81 M. Compared with the lightweight method UNeXt, MLG-UNet improved the mean Dice by 0.69 percentage points and reduced the mean HD95 by 0.38 mm, with lower parameter count and computational complexity. On the BraTS2019 test set, the mean Dice was 86.51% and the mean HD95 was 3.68 mm, also outperforming all compared methods, demonstrating favorable cross-dataset generalization. Ablation experiments showed that BCMB, LRBF, and LGBM all effectively improved segmentation performance. Visual comparison demonstrated higher agreement between the segmentation results of the proposed method and expert annotations. In patient-level five-round repeated holdout validation, the mean Dice was (86.71±0.52)% and the mean HD95 was (3.65±0.14) mm, indicating high stability. Conclusion MLG-UNet achieved a mean Dice of 86.67%, with only 0.81 M parameters, maintaining high brain tumor MRI segmentation accuracy while controlling model size and computational overhead, and exhibits stable segmentation performance across different patient partitions.
SN  - 2097-0927
ER  -