Skip to content
DraconiticResearch
Search Sources API
186,123 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BY 4.0Scientific Reports

MEE-Net: a lightweight CNN with interpretability assessment for cardiomegaly detection from chest X-rays on edge devices

Abstract

Cardiomegaly is a clinically important indicator of cardiovascular risk, yet its detection from chest radiographs remains challenging due to inter-observer variability and the limited deployability of current deep learning models in resource-constrained settings. To address these limitations, we propose MEE-Net (Memory-Efficient Encoder Network), a lightweight convolutional architecture with Grad-CAM-based interpretability assessment, optimized for cardiomegaly detection on edge devices. Architecturally inspired by the encoder path of U-Net and equipped with depthwise-separable convolutions, MEE-Net contains only 83k parameters and omits batch normalization to minimize computational and memory overhead. The model was trained and evaluated on the ChestX-ray8 (5552 samples, balanced) and CheXpert (223,648 samples, imbalanced) datasets using standardized preprocessing and 5-fold cross-validation. On ChestX-ray8, MEE-Net achieved an accuracy of 0.73, F 1 of 0.73, and AUC of 0.81, while on CheXpert it obtained an accuracy of 0.88, F 1 of 0.86, and AUC of 0.81, showing competitive performance compared with the evaluated lightweight CNNs. Computational profiling showed the lowest CPU latency (3.5 ms per inference) and memory usage (0.5 MB) among all evaluated models. Additional evaluation on a Raspberry Pi 4 yielded an average inference latency of 23.2 ms and a runtime memory usage of 19.2 MB, further supporting the potential of MEE-Net for resource-constrained edge deployment. To quantify deployability, an integrated metric termed Edge Suitability Score ( ESS ) was introduced, under which MEE-Net achieved the highest values across all six weighting schemes on ChestX-ray8 (0.89–0.94) and in five of the six schemes on CheXpert (0.70–0.84). Grad-CAM analysis suggested that MEE-Net attention maps mostly overlapped with anatomically relevant thoracic regions, with quantitative spatial alignment metrics indicating coherent correspondence between activation maps and anatomical reference masks. These findings suggest that MEE-Net provides a favorable balance between diagnostic performance and computational efficiency, while offering preliminary evidence of anatomically plausible attention behavior. Therefore, MEE-Net may represent a promising candidate for future resource-constrained cardiomegaly detection applications.

Related

  1. Digital mobility assessment using wearable devices in people with Parkinson’s disease: a feasibility and implementation study in Ghana (TraPCAf) compared with a UK cohort
    Metin Bicer, Cameron Kirk, Mary Agoriwo +14
    Frontiers in aging neurosciencePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. A lightweight deep learning model for real-time in-vehicle driver distraction detection with low-latency inference
    Siham Essahraui, Chaymae Rami, Khalid El Makkaoui +1
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  3. Deep learning-based detection of construction waste in complex scenarios with an improved lightweight algorithm
    YiZhong Yang, YeXue Li, ShengWei Li +2
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePhysiologyPLOS
  4. TCLNet: A Thermal Contrast-Aware Lightweight Network for infrared object detection
    Xiyuan Zhu, Hongtao Dang, Xiaoyuan Jin
    PLOS OnePeer-reviewedCC BYFull textPhysiologyPLOSEurope PMC
  5. Subject-independent Parkinson's Disease Detection through A Lightweight Spectrotemporal Hybrid Network.
    Babak Masoudi
    Journal of medical signals and sensorsPeer-reviewedCC BY-NC-SAFull textPhysiologyEurope PMC
BibTeX
@article{dalveren2026meenet,
  title = {{MEE-Net: a lightweight CNN with interpretability assessment for cardiomegaly detection from chest X-rays on edge devices}},
  author = {Yaser Dalveren and Mehmet Zahid Genc and Ali Kara and Mohammad Derawi and Jan Kubicek and Marek Penhaker},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-73905-w},
  url = {https://www.nature.com/articles/s41598-026-73905-w},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - MEE-Net: a lightweight CNN with interpretability assessment for cardiomegaly detection from chest X-rays on edge devices
AU  - Yaser Dalveren
AU  - Mehmet Zahid Genc
AU  - Ali Kara
AU  - Mohammad Derawi
AU  - Jan Kubicek
AU  - Marek Penhaker
PY  - 2026
DA  - 2026/10/03
JO  - Scientific Reports
DO  - 10.1038/s41598-026-73905-w
UR  - https://www.nature.com/articles/s41598-026-73905-w
AB  - Cardiomegaly is a clinically important indicator of cardiovascular risk, yet its detection from chest radiographs remains challenging due to inter-observer variability and the limited deployability of current deep learning models in resource-constrained settings. To address these limitations, we propose MEE-Net (Memory-Efficient Encoder Network), a lightweight convolutional architecture with Grad-CAM-based interpretability assessment, optimized for cardiomegaly detection on edge devices. Architecturally inspired by the encoder path of U-Net and equipped with depthwise-separable convolutions, MEE-Net contains only 83k parameters and omits batch normalization to minimize computational and memory overhead. The model was trained and evaluated on the ChestX-ray8 (5552 samples, balanced) and CheXpert (223,648 samples, imbalanced) datasets using standardized preprocessing and 5-fold cross-validation. On ChestX-ray8, MEE-Net achieved an accuracy of 0.73, F 1 of 0.73, and AUC of 0.81, while on CheXpert it obtained an accuracy of 0.88, F 1 of 0.86, and AUC of 0.81, showing competitive performance compared with the evaluated lightweight CNNs. Computational profiling showed the lowest CPU latency (3.5 ms per inference) and memory usage (0.5 MB) among all evaluated models. Additional evaluation on a Raspberry Pi 4 yielded an average inference latency of 23.2 ms and a runtime memory usage of 19.2 MB, further supporting the potential of MEE-Net for resource-constrained edge deployment. To quantify deployability, an integrated metric termed Edge Suitability Score ( ESS ) was introduced, under which MEE-Net achieved the highest values across all six weighting schemes on ChestX-ray8 (0.89–0.94) and in five of the six schemes on CheXpert (0.70–0.84). Grad-CAM analysis suggested that MEE-Net attention maps mostly overlapped with anatomically relevant thoracic regions, with quantitative spatial alignment metrics indicating coherent correspondence between activation maps and anatomical reference masks. These findings suggest that MEE-Net provides a favorable balance between diagnostic performance and computational efficiency, while offering preliminary evidence of anatomically plausible attention behavior. Therefore, MEE-Net may represent a promising candidate for future resource-constrained cardiomegaly detection applications.
SN  - 2045-2322
ER  -