Design and development of a full-scale oxygenator model for future biohybrid lung application

Abstract

Use of conventional oxygenators is typically limited to 10–14 days due to poor hemocompatibility. Endothelialization of gas exchange membranes can create a natural non-thrombogenic surface and has proven effective in small laboratory models, but this approach requires a specific oxygenator design that can support both effective gas exchange and future membrane endothelialization. Thus, we developed a modular spiral-coil oxygenator using a fabrication approach that enables the production of a large membrane surface area with integrated blood channels. We designed and fabricated multiple oxygenator prototypes using a rolled flat-sheet PDMS/spacer/PDMS membrane structure and evaluated their gas exchange and fluid flow. Prototypes were tested for gas exchange performance following ISO 7199:2016 standards. Computational fluid dynamics (CFD) simulations were performed to assess flow distribution and wall shear stress (WSS). Among the tested prototypes, two designs provided the most promising results. They achieved surface areas of 0.20 m² and 0.34 m² with priming volumes of 348 mL and 312 mL, respectively. Both models showed quantifiable gas exchange supporting the feasibility of the proposed concept. CFD simulations revealed no stagnant areas and low WSS. These results demonstrate the feasibility of a modular spiral-coil oxygenator with a large-area flat-sheet membrane and millimeter-scale blood channels. While gas transfer requires improvement before clinical applicability for extracorporeal CO ₂ removal, the fabrication approach provides a foundation for future endothelialization and development of long-term biohybrid lung support devices.

Related

  1. A theory-driven mobile application based on iterative collaborative design principles to support depression self-management in older adults: development and usability evaluation of “Mind Garden”
    Ziping Zhu, Zhi Chen, Zhengmin Wang +4
    BMC Public HealthPeer-reviewedCC BY-NC-ND 4.0Epidemiology & public healthCrossref
  2. Development of a database for investigating characteristics and quality of published clinical trials in chronic obstructive pulmonary disease: design, implementation, and application
    Yiyin Zhang, Yanfei Zhao, Peng Zhang +7
    TrialsPeer-reviewedCC BY-NC-ND 4.0Full textClinical trials & evidence synthesisPMC
  3. Brain-computer interfaces in pediatric populations: research advances, application challenges, and future directions
    Shan Wang, Qian Wu, Qiaorong Lei +2
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Development of a Pelvic Finite Element Model for Future Assessment of Fixation Strategies in Both-Column Acetabular Fractures
    Marine Ganachon, Zapata Alves, Rodolfo José +2
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaHAL
  5. Ingestion-mediated toxicity of dinotefuran against Aedes aegypti and its implications for future sugar based toxic bait development
    Mitra Boroomand, Aboozar Soltani, Alireza Sanei-Dehkordi +6
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEpidemiology & public healthCrossref
BibTeX
@article{singh2026design,
  title = {{Design and development of a full-scale oxygenator model for future biohybrid lung application}},
  author = {Abhishek Singh and Kai Janning and Dio Putra Simbolon and Foivos Leonidas Mouzakis and Ali Kashefi and Khosrow Mottaghy and Michael Neidlin and Ruth Olmer and Stefan Jockenhoevel and Christian G. Cornelissen and Anja Lena Thiebes},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-76771-8},
  url = {https://www.nature.com/articles/s41598-026-76771-8},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Design and development of a full-scale oxygenator model for future biohybrid lung application
AU  - Abhishek Singh
AU  - Kai Janning
AU  - Dio Putra Simbolon
AU  - Foivos Leonidas Mouzakis
AU  - Ali Kashefi
AU  - Khosrow Mottaghy
AU  - Michael Neidlin
AU  - Ruth Olmer
AU  - Stefan Jockenhoevel
AU  - Christian G. Cornelissen
AU  - Anja Lena Thiebes
PY  - 2026
DA  - 2026/10/20
JO  - Scientific Reports
DO  - 10.1038/s41598-026-76771-8
UR  - https://www.nature.com/articles/s41598-026-76771-8
AB  - Use of conventional oxygenators is typically limited to 10–14 days due to poor hemocompatibility. Endothelialization of gas exchange membranes can create a natural non-thrombogenic surface and has proven effective in small laboratory models, but this approach requires a specific oxygenator design that can support both effective gas exchange and future membrane endothelialization. Thus, we developed a modular spiral-coil oxygenator using a fabrication approach that enables the production of a large membrane surface area with integrated blood channels. We designed and fabricated multiple oxygenator prototypes using a rolled flat-sheet PDMS/spacer/PDMS membrane structure and evaluated their gas exchange and fluid flow. Prototypes were tested for gas exchange performance following ISO 7199:2016 standards. Computational fluid dynamics (CFD) simulations were performed to assess flow distribution and wall shear stress (WSS). Among the tested prototypes, two designs provided the most promising results. They achieved surface areas of 0.20 m² and 0.34 m² with priming volumes of 348 mL and 312 mL, respectively. Both models showed quantifiable gas exchange supporting the feasibility of the proposed concept. CFD simulations revealed no stagnant areas and low WSS. These results demonstrate the feasibility of a modular spiral-coil oxygenator with a large-area flat-sheet membrane and millimeter-scale blood channels. While gas transfer requires improvement before clinical applicability for extracorporeal CO ₂ removal, the fabrication approach provides a foundation for future endothelialization and development of long-term biohybrid lung support devices.
SN  - 2045-2322
ER  -