Comparison of Outcomes After Custom-Q LASIK, Custom-Q PRK, and Keratorefractive Lenticule Extraction: Corneal Higher-Order Aberrations and Asphericity
- 1Department of Ophthalmology, Veterans Health Service Medical Center, Seoul 05368, Republic of Korea
- 2First Samsung Eye Clinic, Seoul 06621, Republic of Korea
- 3College of Arts and Science, New York University, New York, NY 10003, USA
Abstract
Background/Objectives: We compared refractive outcomes, corneal higher-order aberrations (HOAs), and asphericity (Q-value) after Custom-Q laser in situ keratomileusis (CQ-LASIK), Custom-Q photorefractive keratectomy (CQ-PRK), and keratorefractive lenticule extraction (KLEx), three treatment approaches rarely compared directly. Methods: This retrospective cohort study included 214 eyes of 107 patients treated with CQ-LASIK (62 eyes), CQ-PRK (78 eyes), or KLEx (CLEAR, FEMTO LDV Z8; 74 eyes) (2023–2025; 6.5-mm optical zone). Coma, trefoil, primary spherical aberration (SA), and total HOAs at 2.0–7.0 mm and Q-values at 6.0–9.0 mm were compared preoperatively and at 6 months using generalized estimating equations accounting for inter-eye correlation, with Bonferroni-adjusted pairwise comparisons. Results: Uncorrected distance visual acuity was 20/20 or better in 95%, 96%, and 96% of eyes, and the spherical equivalent was within ±1.0 D in 96.6%, 97.9%, and 97.4% after CQ-LASIK, CQ-PRK, and KLEx, respectively. Induced coma and trefoil did not differ among the groups at any diameter. At 5.0 mm, induced SA was greater after CQ-PRK than after CQ-LASIK or KLEx; at 6.0 and 7.0 mm it followed the order CQ-PRK > CQ-LASIK > KLEx (6.0 mm: 0.31, 0.09, and 0.03 µm), as did the oblate Q-value shift (all adjusted p < 0.05); a one-eye-per-patient sensitivity analysis was consistent. Conclusions: At 6 months, the three procedures corrected refraction comparably and preserved central corneal optics but differed in peripheral corneal optical profiles, with induced SA and oblate shape change greatest after CQ-PRK and smallest after CLEAR-based KLEx. These modest differences require prospective confirmation of their effect on visual function.
Related
- Comparison of Treatment Zone Decentration Between VISUMAX 500 and VISUMAX 800 Keratorefractive Lenticule Extraction Using Anterior Segment Optical Coherence Tomography
- Pressure-Induced Stromal Keratitis After Keratorefractive Lenticule Extraction: A Review of Emerging Evidence
- Relationship between corneal cutting ratio and early postoperative Q values and higher-order aberrations after small incision lenticule extraction in myopic patients
- Three-Month Ocular Surface and Dry-Eye Outcomes After Implantable Collamer Lens (ICL) Implantation versus Small-Incision Lenticule Extraction (SMILE): A Prospective Non-Randomized Comparative Cohort Study
- Comparison of corneal higher order aberrations in diabetics versus non-diabetics after cataract surgery.
BibTeX
@article{ko2026comparison,
title = {{Comparison of Outcomes After Custom-Q LASIK, Custom-Q PRK, and Keratorefractive Lenticule Extraction: Corneal Higher-Order Aberrations and Asphericity}},
author = {Jiyeon Ko and Sung-Ho Choi and Sangkyung Choi and Yoonseong Choi and Deokjo Nam},
journal = {Journal of Clinical Medicine},
year = {2026},
month = nov,
doi = {10.3390/jcm15239253},
url = {https://www.mdpi.com/2077-0383/15/23/9253},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Comparison of Outcomes After Custom-Q LASIK, Custom-Q PRK, and Keratorefractive Lenticule Extraction: Corneal Higher-Order Aberrations and Asphericity
AU - Jiyeon Ko
AU - Sung-Ho Choi
AU - Sangkyung Choi
AU - Yoonseong Choi
AU - Deokjo Nam
PY - 2026
DA - 2026/11/25
JO - Journal of Clinical Medicine
DO - 10.3390/jcm15239253
UR - https://www.mdpi.com/2077-0383/15/23/9253
AB - Background/Objectives: We compared refractive outcomes, corneal higher-order aberrations (HOAs), and asphericity (Q-value) after Custom-Q laser in situ keratomileusis (CQ-LASIK), Custom-Q photorefractive keratectomy (CQ-PRK), and keratorefractive lenticule extraction (KLEx), three treatment approaches rarely compared directly. Methods: This retrospective cohort study included 214 eyes of 107 patients treated with CQ-LASIK (62 eyes), CQ-PRK (78 eyes), or KLEx (CLEAR, FEMTO LDV Z8; 74 eyes) (2023–2025; 6.5-mm optical zone). Coma, trefoil, primary spherical aberration (SA), and total HOAs at 2.0–7.0 mm and Q-values at 6.0–9.0 mm were compared preoperatively and at 6 months using generalized estimating equations accounting for inter-eye correlation, with Bonferroni-adjusted pairwise comparisons. Results: Uncorrected distance visual acuity was 20/20 or better in 95%, 96%, and 96% of eyes, and the spherical equivalent was within ±1.0 D in 96.6%, 97.9%, and 97.4% after CQ-LASIK, CQ-PRK, and KLEx, respectively. Induced coma and trefoil did not differ among the groups at any diameter. At 5.0 mm, induced SA was greater after CQ-PRK than after CQ-LASIK or KLEx; at 6.0 and 7.0 mm it followed the order CQ-PRK > CQ-LASIK > KLEx (6.0 mm: 0.31, 0.09, and 0.03 µm), as did the oblate Q-value shift (all adjusted p < 0.05); a one-eye-per-patient sensitivity analysis was consistent. Conclusions: At 6 months, the three procedures corrected refraction comparably and preserved central corneal optics but differed in peripheral corneal optical profiles, with induced SA and oblate shape change greatest after CQ-PRK and smallest after CLEAR-based KLEx. These modest differences require prospective confirmation of their effect on visual function.
SN - 2077-0383
ER -