Skip to content
DraconiticResearch
Search Sources API
206,698 studies31 sourcesUpdated 1 h ago
PreprintCC BY 4.0arXiv

Rapid Antigen Detection Tests Empowered by Cholesteric Spherical Reflectors for Expanded Capabilities

Abstract

While Rapid Antigen Detection Tests (RADTs) have proved their value in point-of-care detection of respiratory diseases, their poor-contrast readout limits their use at early stages of infection where viral concentrations are low, and most RADTs test only for one disease, leaving a sick patient ignorant in case of a negative result. We explore the potential of Cholesteric Spherical Reflectors (CSRs) as enhanced optical labeling probes for RADTs, leveraging their circularly polarized reflections to maximize contrast by background subtraction and thereby lower the analyte concentration required for detection. Moreover, we demonstrate how the ease in tuning the CSR reflection color and the freedom to choose between right- and left-handed circularly polarized reflection allow us to design CSRs to distinguish optically between multiple diseases, eventually enabling RADTs capable of screening for a set of multiple diseases in a single test. We develop a method for functionalizing CSRs with appropriate antibodies and we propose a new type of RADT specifically designed for use with CSRs as detection label, demonstrating that the comparatively large size of CSRs (tens of microns in diameter) does not prevent viral analytes to tether them to an antibody-coated test surface. The strength of the optical CSR signal quantitatively reflects the antigen concentration.

Related

  1. High-responsivity and high-output-power MUTC-PD utilizing distributed Bragg reflectors
    Mengjing Xu, Zixuan Cheng, Qian Yu +9
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  2. Modulated structures in discrete approximations to a three-dimensional cholesteric model on a recursive lattice
    William de Castilho
    arXivPreprintCC BY-NC-ND 4.0Full textStatistical & nonlinear physicsarXiv
  3. Design of Mechanically Compliant Membrane Reflectors for Giant Optical Phase Nonlinearity
    Lior Michaeli, Harry A. Atwater
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationCondensed matterarXiv
  4. Perfect absorption by metal-contacted two-dimensional systems with ultra-proximate reflectors
    Kirill Kapralov, Vladislav Atlasov, Alina Khisameeva +2
    arXivPreprintCC BY 4.0Full textCondensed matterOptics & photonicsarXiv
  5. High-energy low-repetition broadband ultrafast lasers empowered by hollow-core fiber
    Laiyang Dang, Xin Zhang, Yinghui Zhuang +6
    Nature CommunicationsPeer-reviewedCC BY-NC-ND 4.0Full textOptics & photonicsCrossrefEurope PMCPMC
BibTeX
@misc{chien2026rapid,
  title = {{Rapid Antigen Detection Tests Empowered by Cholesteric Spherical Reflectors for Expanded Capabilities}},
  author = {Chih-Chieh Chien and Yan-Song Zhang and Jean-François Conrotte and Carole L. Linster and Sivashankar Krishnamoorthy and Jan P. F. Lagerwall},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.09948},
  eprint = {2611.09948},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.09948},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Rapid Antigen Detection Tests Empowered by Cholesteric Spherical Reflectors for Expanded Capabilities
AU  - Chih-Chieh Chien
AU  - Yan-Song Zhang
AU  - Jean-François Conrotte
AU  - Carole L. Linster
AU  - Sivashankar Krishnamoorthy
AU  - Jan P. F. Lagerwall
PY  - 2026
DA  - 2026/11/01
PB  - arXiv
DO  - 10.48550/arxiv.2611.09948
UR  - https://arxiv.org/abs/2611.09948
AB  - While Rapid Antigen Detection Tests (RADTs) have proved their value in point-of-care detection of respiratory diseases, their poor-contrast readout limits their use at early stages of infection where viral concentrations are low, and most RADTs test only for one disease, leaving a sick patient ignorant in case of a negative result. We explore the potential of Cholesteric Spherical Reflectors (CSRs) as enhanced optical labeling probes for RADTs, leveraging their circularly polarized reflections to maximize contrast by background subtraction and thereby lower the analyte concentration required for detection. Moreover, we demonstrate how the ease in tuning the CSR reflection color and the freedom to choose between right- and left-handed circularly polarized reflection allow us to design CSRs to distinguish optically between multiple diseases, eventually enabling RADTs capable of screening for a set of multiple diseases in a single test. We develop a method for functionalizing CSRs with appropriate antibodies and we propose a new type of RADT specifically designed for use with CSRs as detection label, demonstrating that the comparatively large size of CSRs (tens of microns in diameter) does not prevent viral analytes to tether them to an antibody-coated test surface. The strength of the optical CSR signal quantitatively reflects the antigen concentration.
ER  -