Skip to content
DraconiticResearch
Search Sources API
210,049 studies31 sourcesUpdated 1 h ago
Peer-reviewedCC BY-NC-ND 4.0Journal of Cardiothoracic Surgery

Transcatheter aortic valve implantation in bicuspid aortic valve regurgitation: a case report

  1. 1Present Address: Interventional Center of Valvular Heart Disease, Beijing Anzhen Hospital, Capital Medical University, No.2 Anzhen Road, Chaoyang District, Beijing, 100029 China

Abstract

Background: Transcatheter aortic valve implantation (TAVI) for pure aortic regurgitation (AR) remains challenging, especially in bicuspid aortic valve (BAV) anatomy, which has been excluded from pivotal trials of dedicated AR devices. Whether cusp-engaging devices can be used in type 1 BAV with raphe is unknown.

Case presentation: We report two East Asian male patients (aged 72 and 62 years) with severe pure AR and type 1 bicuspid aortic valve, confirmed by transthoracic echocardiography. Pre-procedural multidetector computed tomography (MDCT) demonstrated a raphe between the left and right coronary cusps in both patients, with relatively symmetric cusp sizes and minimal calcification. Self-expanding Taurus-Trio valves (27 mm and 25 mm, respectively) were successfully implanted under monitored anaesthesia care (MAC) with TTE guidance. Post-procedural TTE showed only trivial paravalvular leak (PVL). At 6-month follow-up, MDCT confirmed favourable valve performance, with all three locators appropriately engaged within the corresponding cusps, preserved leaflet morphology and motion, and no evidence of hypo-attenuated leaflet thickening (HALT). Neither patient developed new conduction disturbances requiring permanent pacemaker implantation.

Conclusions: This case report demonstrates the feasibility of using a dedicated cusp-engaging transcatheter valve in carefully selected patients with type 1 BAV-AR, favourable cusp symmetry, and minimal calcification. These findings are hypothesis-generating and warrant further investigation; they should not be generalised to all BAV subtypes or to patients with significant calcification.

Related

  1. Transcatheter Aortic Valve Implantation in Complex Anatomy: An Anatomy-Driven Framework for Bicuspid Stenosis, Pure Aortic Regurgitation, and the Small Annulus in the Era of Lifetime Management
    Daniel Miron Brie, Cristian Mornoș, Roxana Popescu +1
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Transcatheter Aortic Valve Implantation for Pure Native Aortic Regurgitation: A Comprehensive State-of-the-Art Review
    Joao Matteo Rampone, Samuele Sandrone, Sergio Capoccia +9
    Reviews in Cardiovascular MedicinePeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
  3. Modified balloon-assisted shoehorn technique for transcatheter aortic valve implantation in functionally horizontal anatomy: a case report
    European heart journal. Case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Acute Severe Aortic Regurgitation Immediately After Cardiopulmonary Bypass Initiation in a Patient With a Bicuspid Aortic Valve
    Takumi Yamamoto, Keisuke Sumii
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Severe dynamic left-ventricular outflow-tract obstruction unmasked by transcatheter aortic valve implantation: a case report
    Zongmei Gao, Minghui Yuan, Yi Li +2
    European Heart Journal. Case ReportsPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMCEurope PMC
BibTeX
@article{su2026transcatheter,
  title = {{Transcatheter aortic valve implantation in bicuspid aortic valve regurgitation: a case report}},
  author = {Hang Su and Jing Yao and Guangyuan Song},
  journal = {Journal of Cardiothoracic Surgery},
  year = {2026},
  month = aug,
  doi = {10.1186/s13019-026-04640-6},
  url = {https://doi.org/10.1186/s13019-026-04640-6},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Transcatheter aortic valve implantation in bicuspid aortic valve regurgitation: a case report
AU  - Hang Su
AU  - Jing Yao
AU  - Guangyuan Song
PY  - 2026
DA  - 2026/08/11
JO  - Journal of Cardiothoracic Surgery
DO  - 10.1186/s13019-026-04640-6
UR  - https://doi.org/10.1186/s13019-026-04640-6
AB  - Background: Transcatheter aortic valve implantation (TAVI) for pure aortic regurgitation (AR) remains challenging, especially in bicuspid aortic valve (BAV) anatomy, which has been excluded from pivotal trials of dedicated AR devices. Whether cusp-engaging devices can be used in type 1 BAV with raphe is unknown.  Case presentation: We report two East Asian male patients (aged 72 and 62 years) with severe pure AR and type 1 bicuspid aortic valve, confirmed by transthoracic echocardiography. Pre-procedural multidetector computed tomography (MDCT) demonstrated a raphe between the left and right coronary cusps in both patients, with relatively symmetric cusp sizes and minimal calcification. Self-expanding Taurus-Trio valves (27 mm and 25 mm, respectively) were successfully implanted under monitored anaesthesia care (MAC) with TTE guidance. Post-procedural TTE showed only trivial paravalvular leak (PVL). At 6-month follow-up, MDCT confirmed favourable valve performance, with all three locators appropriately engaged within the corresponding cusps, preserved leaflet morphology and motion, and no evidence of hypo-attenuated leaflet thickening (HALT). Neither patient developed new conduction disturbances requiring permanent pacemaker implantation.  Conclusions: This case report demonstrates the feasibility of using a dedicated cusp-engaging transcatheter valve in carefully selected patients with type 1 BAV-AR, favourable cusp symmetry, and minimal calcification. These findings are hypothesis-generating and warrant further investigation; they should not be generalised to all BAV subtypes or to patients with significant calcification.
SN  - 1749-8090
ER  -