Personal earplug fit testing identifies below-target attenuation in nearly two-thirds of military aviation personnel: a retrospective analysis of results before and after individualized instruction
- 1The Adelson School of Medicine, Ariel University , ,
Abstract
Background: Noise-induced hearing loss (NIHL) remains an important occupational health problem, especially in high-intensity noise work settings. Although disposable foam earplugs (DFE) are widely used, the protection they provide depends on how well they are fitted. We examined initial earplug attenuation in military aviation personnel, the change observed after individualized on-site instruction and repeat fitting among participants initially below target, and the association between previous instruction and baseline attenuation.
Methods: This retrospective, single-center observational study analyzed routinely collected occupational-health fit-testing data from 183 military aviation personnel evaluated between 2020 and 2022. Mean age was 22.84 ± 6.23 years, and 91.3% were male. Earplug attenuation was measured using the 3M E-A-Rfit Dual-Ear Validation System. Participants with mean binaural attenuation below 20 dB received individualized on-site instruction and repeated the fitting procedure.
Results: During initial fitting, 118 participants (64.5%) did not achieve the 20 dB target. In this group, mean binaural attenuation rose from 14.47 to 22.57 dB after instruction and repeat fitting, an improvement of 8.10 dB ( p < 0.001). Participants who reported having received previous earplug-use instruction also had higher baseline attenuation than those without previous instruction (19.47 vs. 16.52 dB; p = 0.002).
Conclusion: Quantitative fit testing identified inadequate initial attenuation in nearly two-thirds of the personnel assessed. Brief individualized instruction followed by repeat fitting was associated with a substantial improvement in attenuation among those initially below target. Incorporating personal fit testing and targeted instruction into occupational hearing-conservation programs may improve protection against NIHL.
Related
- Medical fitness trajectories and associated factors among licensed aviation personnel in Korea: a retrospective cohort study
- WFUMB-Recommended Versus Manufacturer-Optimized Protocols for Ultrasound-Guided Attenuation Parameter in Hepatic Steatosis Assessment: A Retrospective Single-Vendor Multicenter Study
- Computed Tomography Angiography-Derived Pericoronary Fat Attenuation Index and AI-Based Cardiovascular Risk Score as a Proposed New Pathway in a Rapid Access Chest Pain Clinic: A Single-Centre Retrospective Registry Study
- Growth hormone intrauterine perfusion improves pregnancy outcomes in frozen-thawed embryo transfer cycles and identifies effect modifiers: a propensity score-matched single-center retrospective cohort study.
- Integrated omics analysis identifies GSTA1 and ALDH1A1 as candidate biomarkers for low-level albuminuric diabetic kidney disease: a mixed prospective-retrospective cross-sectional study
BibTeX
@article{argaman2026personal,
title = {{Personal earplug fit testing identifies below-target attenuation in nearly two-thirds of military aviation personnel: a retrospective analysis of results before and after individualized instruction}},
author = {Moshe Argaman and Oded Ben-Ari},
journal = {Frontiers in public health},
year = {2026},
month = sep,
doi = {10.3389/fpubh.2026.1955670},
url = {https://europepmc.org/article/PMC/PMC13661490},
note = {CC BY},
}
RIS
TY - JOUR
TI - Personal earplug fit testing identifies below-target attenuation in nearly two-thirds of military aviation personnel: a retrospective analysis of results before and after individualized instruction
AU - Moshe Argaman
AU - Oded Ben-Ari
PY - 2026
DA - 2026/09/30
JO - Frontiers in public health
DO - 10.3389/fpubh.2026.1955670
UR - https://europepmc.org/article/PMC/PMC13661490
AB - Background: Noise-induced hearing loss (NIHL) remains an important occupational health problem, especially in high-intensity noise work settings. Although disposable foam earplugs (DFE) are widely used, the protection they provide depends on how well they are fitted. We examined initial earplug attenuation in military aviation personnel, the change observed after individualized on-site instruction and repeat fitting among participants initially below target, and the association between previous instruction and baseline attenuation. Methods: This retrospective, single-center observational study analyzed routinely collected occupational-health fit-testing data from 183 military aviation personnel evaluated between 2020 and 2022. Mean age was 22.84 ± 6.23 years, and 91.3% were male. Earplug attenuation was measured using the 3M E-A-Rfit Dual-Ear Validation System. Participants with mean binaural attenuation below 20 dB received individualized on-site instruction and repeated the fitting procedure. Results: During initial fitting, 118 participants (64.5%) did not achieve the 20 dB target. In this group, mean binaural attenuation rose from 14.47 to 22.57 dB after instruction and repeat fitting, an improvement of 8.10 dB ( p < 0.001). Participants who reported having received previous earplug-use instruction also had higher baseline attenuation than those without previous instruction (19.47 vs. 16.52 dB; p = 0.002). Conclusion: Quantitative fit testing identified inadequate initial attenuation in nearly two-thirds of the personnel assessed. Brief individualized instruction followed by repeat fitting was associated with a substantial improvement in attenuation among those initially below target. Incorporating personal fit testing and targeted instruction into occupational hearing-conservation programs may improve protection against NIHL.
SN - 2296-2565
ER -