SynForge-Cardio: a unified multimodal synthetic dataset generation framework for privacy-preserving cardiovascular AI.
- 1Department of Electronics and Communication Engineering, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Chennai, Tamil Nadu, India.
Abstract
Multimodal cardiovascular AI systems benefit from jointly available chest radiographs, 12-lead electrocardiograms (ECGs), and structured electronic health record (EHR) variables. In practice, multi-institutional model development is constrained by privacy regulations, institutional data silos, and class imbalance for less common findings. Existing open-source synthetic data tools are largely modality-specific: tabular libraries such as Synthetic Data Vault (SDV)/Conditional Tabular Generative Adversarial Network (CTGAN), image generators based on latent diffusion, and time-series methods such as Time-series Generative Adversarial Network (TimeGAN) each require its own setup, configuration, and validation. This study presents SynForge-Cardio, a multimodality orchestration framework for prompt-driven synthetic dataset generation across chest X-ray (CXR), 12-lead ECG, and EHR modalities. Rather than introducing a new generative backbone, SynForge-Cardio coordinates established components-latent diffusion with optional low-rank adaptation for CXR; parametric and bounded morphology-preserving augmentation (with an optional TimeGAN path) for ECG; and size-aware routing among jitter augmentation, Gaussian copula, and CTGAN/Tabular Variational Autoencoder for EHR-behind a shared clinical prompt interface, a rule-based router, and a postgeneration quality/privacy reporting layer. The three modalities were generated independently from separate datasets; the framework does not perform patient-level joint synthesis and makes no claim of anatomical or physiological consistency across modalities. This system is implemented as a FastAPI backend with a React frontend and can run on a single workstation GPU. Herein, we formalize the orchestration objective, specify modality-wise models and metrics [Fréchet Inception Distance (FID), dynamic time warping (DTW), power spectral density similarity, Kolmogorov-Smirnov statistics, correlation preservation, and distance-to-closest-record privacy screening], and describe an evaluation protocol on public corpora (NIH Chest X-ray14, PTB-XL, and the UCI Cleveland Heart Disease dataset), including a four-regime train-on-synthetic/test-on-real (TSTR) utility analysis with five random seeds. On the framework alone, we measured 94.6% modality-routing accuracy, 100% direct-vs.-routed generation equivalence on the evaluated cases, 59 unnecessary generator calls avoided, and 100% validation/reporting completeness (1,105/1,108 tests pass, 3 skipped). Downstream-utility results were mixed: augmenting a 25%-real training set with synthetic data changed the held-out AUROC by -0.041 to +0.050 across three CXR tasks (none significant at five seeds); by +0.019 for ECG MI-vs.-NORM [produced by mode B (bounded real-waveform augmentation, whose synthetic samples can be matched to their true source recording at top-1 ≈ 42.7-43.4%, and hence, mode B is not an independently learned generative model)]; and by +0.017 for EHR heart disease classification, which is not evidence of benefit given the 61-record hold-out set (the test-set bootstrap 95% CI for the difference includes zero). Medical Information Mart for Intensive Care IV acquisition was not completed because credentialed access was unavailable; all reported EHR results were UCI-based. SynForge-Cardio is intended as a practical, reproducible research framework for privacy-conscious cardiovascular data augmentation and prototype development.
Related
- Evaluating a Large Language Model for Emergency Triage Using Synthetic Clinical Dialogues: Toward a Multimodal Clinical Safety Framework
- A physiologically constrained calibration framework for cardiovascular models applied to a paediatric synthetic sepsis population
- Generative AI for Synthetic Medical Image Generation in Oncology: Addressing Data Scarcity in AI-Driven Cancer Diagnosis
- From Task-Specific AI to Cardiovascular Foundation Models: A New Era of Multimodal Interpretation
- Structure-preserving Image-quality Enhancement for 3D Synthetic FLAIR Using a 3D U-Net with Content and Style Losses
BibTeX
@article{kumar2026synforgecardio,
title = {{SynForge-Cardio: a unified multimodal synthetic dataset generation framework for privacy-preserving cardiovascular AI.}},
author = {Sreyas Sanil Kumar and Kishore N and Amirthalakshmi T M and Rahul S G},
journal = {Frontiers in digital health},
year = {2026},
month = nov,
doi = {10.3389/fdgth.2026.1946730},
url = {https://europepmc.org/article/MED/43080490},
note = {CC BY},
}
RIS
TY - JOUR
TI - SynForge-Cardio: a unified multimodal synthetic dataset generation framework for privacy-preserving cardiovascular AI.
AU - Sreyas Sanil Kumar
AU - Kishore N
AU - Amirthalakshmi T M
AU - Rahul S G
PY - 2026
DA - 2026/11/10
JO - Frontiers in digital health
DO - 10.3389/fdgth.2026.1946730
UR - https://europepmc.org/article/MED/43080490
AB - Multimodal cardiovascular AI systems benefit from jointly available chest radiographs, 12-lead electrocardiograms (ECGs), and structured electronic health record (EHR) variables. In practice, multi-institutional model development is constrained by privacy regulations, institutional data silos, and class imbalance for less common findings. Existing open-source synthetic data tools are largely modality-specific: tabular libraries such as Synthetic Data Vault (SDV)/Conditional Tabular Generative Adversarial Network (CTGAN), image generators based on latent diffusion, and time-series methods such as Time-series Generative Adversarial Network (TimeGAN) each require its own setup, configuration, and validation. This study presents SynForge-Cardio, a multimodality orchestration framework for prompt-driven synthetic dataset generation across chest X-ray (CXR), 12-lead ECG, and EHR modalities. Rather than introducing a new generative backbone, SynForge-Cardio coordinates established components-latent diffusion with optional low-rank adaptation for CXR; parametric and bounded morphology-preserving augmentation (with an optional TimeGAN path) for ECG; and size-aware routing among jitter augmentation, Gaussian copula, and CTGAN/Tabular Variational Autoencoder for EHR-behind a shared clinical prompt interface, a rule-based router, and a postgeneration quality/privacy reporting layer. The three modalities were generated independently from separate datasets; the framework does not perform patient-level joint synthesis and makes no claim of anatomical or physiological consistency across modalities. This system is implemented as a FastAPI backend with a React frontend and can run on a single workstation GPU. Herein, we formalize the orchestration objective, specify modality-wise models and metrics [Fréchet Inception Distance (FID), dynamic time warping (DTW), power spectral density similarity, Kolmogorov-Smirnov statistics, correlation preservation, and distance-to-closest-record privacy screening], and describe an evaluation protocol on public corpora (NIH Chest X-ray14, PTB-XL, and the UCI Cleveland Heart Disease dataset), including a four-regime train-on-synthetic/test-on-real (TSTR) utility analysis with five random seeds. On the framework alone, we measured 94.6% modality-routing accuracy, 100% direct-vs.-routed generation equivalence on the evaluated cases, 59 unnecessary generator calls avoided, and 100% validation/reporting completeness (1,105/1,108 tests pass, 3 skipped). Downstream-utility results were mixed: augmenting a 25%-real training set with synthetic data changed the held-out AUROC by -0.041 to +0.050 across three CXR tasks (none significant at five seeds); by +0.019 for ECG MI-vs.-NORM [produced by mode B (bounded real-waveform augmentation, whose synthetic samples can be matched to their true source recording at top-1 ≈ 42.7-43.4%, and hence, mode B is not an independently learned generative model)]; and by +0.017 for EHR heart disease classification, which is not evidence of benefit given the 61-record hold-out set (the test-set bootstrap 95% CI for the difference includes zero). Medical Information Mart for Intensive Care IV acquisition was not completed because credentialed access was unavailable; all reported EHR results were UCI-based. SynForge-Cardio is intended as a practical, reproducible research framework for privacy-conscious cardiovascular data augmentation and prototype development.
SN - 2673-253X
ER -