Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 43 min ago
Peer-reviewedCC BY-NC-ND 4.0Iranian Journal of Veterinary Research

A developed recombinant antigen and monoclonal antibody based solid phase competitive ELISA for detection of foot and mouth disease virus serotype O specific antibodies

  1. 1ICAR-National Institute on Foot and Mouth Disease, Arugul, Bhubaneswar-752050, Odisha, India
  2. 2MSc in Biotechnology, ICAR-National Institute on Foot and Mouth Disease, Arugul, Bhubaneswar-752050, Odisha, India

Abstract

Background:: Foot and mouth disease (FMD) is ahighly contagious and economically burdensome viral disease of cloven-hoofed animals. Out of the seven FMD virus (FMDV) serotypes, type O is one of the most prevalent serotype in several parts of the world.

Aims:: This study aimed to develop a recombinant capsid polyprotein (rP1) and monoclonal antibody (MAb)-based solid phase competitive ELISA (rP1-MAb-SPCE) to detect anti-FMDV/O antibodies in serum samples.

Methods:: For the development of rP1-MAb-SPCE the concentrations of rP1, MAb and dilution of serum were optimized. Percent inhibition (PI) cut-off was determined based on ROC curve analysis of cattle sera (n=53) of known FMD vaccination status with reference to the gold standard virus neutralization test (VNT). The assay performance was further validated in comparison to the conventional polyclonal antibody (PAb)-based SPCE using FMDV-positive and negative serum samples (n=612) obtained from multiple species (cattle, goat, pig, fallow deer, antelope, giraffe and African buffalo).

Results:: At the selected cut-off value of 30.77 PI, the rP1-MAb-SPCE exhibited 86.21% diagnostic sensitivity and 95.83% diagnostic specificity. A significant correlation (r=0.84; P<0.0001) was observed between the PI values of sera tested by rP1-MAb-SPCE and PAb-based SPCE and also the limits of detection of both of the assays were comparable. Repeatability tests demonstrated that the coefficients of variation within and between runs were <10% and <14%, respectively.

Conclusion:: The developed rP1-MAb-SPCE has the potential to facilitate the detection of antibodies against FMDV serotype O while mitigating biosecurity concerns. However, further validation involving a larger serum cohort is essential to confirm the assay’s robustness.

Related

  1. Newly developed monoclonal antibodies for marmoset immunosuppression enable KSHV lytic replication and salivary shedding: A promising model for KSHV pathogenesis studies
    Li Han, Esther Rodriguez, Caitlin Shaw +11
    PLOS PathogensPeer-reviewedCC BY 4.0Full textCell biologyImmunologyPLOSPMC
  2. DNA-Barcoded Polysaccharide Specific Monoclonal Antibodies Facilitate Sensitive and Multiplexed Detection of Cell Wall Polymers.
    C Frankie Griffith, Michael G Hahn, Ian S Wallace
    Plant biotechnology journalPeer-reviewedCC BYFull textPlant biologyEurope PMCPMC
  3. Phenuivirus glycoprotein Gc domain is a conserved target of cross-functional monoclonal antibodies
    D. Guerra, E. Cherubini, M. R. Echague +16
    bioRxivPreprintAll rights reservedFull textImmunologybioRxiv
  4. N1 neuraminidase monoclonal antibodies 2H08 and 3H03 have decreased binding and inhibition properties against H1N1 influenza viruses circulating after 2018
    D. Bhavsar, E. Hermann, B. Monahan +4
    bioRxivPreprintCC BY-NC-NDFull textMicrobiologybioRxiv
  5. IgM monoclonal antibodies reduce IgG-mediated antibody-dependent enhancement of Zika and dengue virus infectivity
    Matthias Lingemann, Taylor J. McGee, Giacomo Sidoti Migliore +3
    iSciencePeer-reviewedCC BY-NC-ND 4.0Full textImmunologyMicrobiologyCell PressCrossrefPMCEurope PMC
BibTeX
@article{mallick2026developed,
  title = {{A developed recombinant antigen and monoclonal antibody based solid phase competitive ELISA for detection of foot and mouth disease virus serotype O specific antibodies}},
  author = {S. Mallick and R. P. Singh and J. K. Biswal and J. K. Mohapatra and M. Rout and S. K. Kabi and R. Ranjan},
  journal = {Iranian Journal of Veterinary Research},
  year = {2026},
  month = aug,
  doi = {10.22099/ijvr.2026.53916.8090},
  url = {https://doi.org/10.22099/ijvr.2026.53916.8090},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - A developed recombinant antigen and monoclonal antibody based solid phase competitive ELISA for detection of foot and mouth disease virus serotype O specific antibodies
AU  - S. Mallick
AU  - R. P. Singh
AU  - J. K. Biswal
AU  - J. K. Mohapatra
AU  - M. Rout
AU  - S. K. Kabi
AU  - R. Ranjan
PY  - 2026
DA  - 2026/08/22
JO  - Iranian Journal of Veterinary Research
DO  - 10.22099/ijvr.2026.53916.8090
UR  - https://doi.org/10.22099/ijvr.2026.53916.8090
AB  - Background:: Foot and mouth disease (FMD) is ahighly contagious and economically burdensome viral disease of cloven-hoofed animals. Out of the seven FMD virus (FMDV) serotypes, type O is one of the most prevalent serotype in several parts of the world.  Aims:: This study aimed to develop a recombinant capsid polyprotein (rP1) and monoclonal antibody (MAb)-based solid phase competitive ELISA (rP1-MAb-SPCE) to detect anti-FMDV/O antibodies in serum samples.  Methods:: For the development of rP1-MAb-SPCE the concentrations of rP1, MAb and dilution of serum were optimized. Percent inhibition (PI) cut-off was determined based on ROC curve analysis of cattle sera (n=53) of known FMD vaccination status with reference to the gold standard virus neutralization test (VNT). The assay performance was further validated in comparison to the conventional polyclonal antibody (PAb)-based SPCE using FMDV-positive and negative serum samples (n=612) obtained from multiple species (cattle, goat, pig, fallow deer, antelope, giraffe and African buffalo).  Results:: At the selected cut-off value of 30.77 PI, the rP1-MAb-SPCE exhibited 86.21% diagnostic sensitivity and 95.83% diagnostic specificity. A significant correlation (r=0.84; P<0.0001) was observed between the PI values of sera tested by rP1-MAb-SPCE and PAb-based SPCE and also the limits of detection of both of the assays were comparable. Repeatability tests demonstrated that the coefficients of variation within and between runs were <10% and <14%, respectively.  Conclusion:: The developed rP1-MAb-SPCE has the potential to facilitate the detection of antibodies against FMDV serotype O while mitigating biosecurity concerns. However, further validation involving a larger serum cohort is essential to confirm the assay’s robustness.
SN  - 1728-1997
SN  - 2252-0589
ER  -