Transthoracic Echocardiography-Assisted, Low-Fluoroscopy Left Bundle Branch Area Pacing: A Comparison of Implantation Approaches and Lead Types.
6 affiliations
- 1Cardiovascular Division, Department of Internal Medicine, MacKay Memorial Hospital, Taipei 104217, Taiwan.
- 2Department of Nursing, MacKay Junior College of Medicine, Nursing, and Management, New Taipei City 252005, Taiwan.
- 3Institute of Biomedical Sciences, MacKay Medical University, New Taipei City 252005, Taiwan.
- 4Department of Medicine, MacKay Medical University, New Taipei City 252005, Taiwan.
- 5Department of Telehealth, MacKay Memorial Hospital, Taipei 104217, Taiwan.
- 6School of Nursing, MacKay Medical University, Taipei 252005, Taiwan.
Abstract
Background: Transthoracic echocardiography (TTE)-assisted left bundle branch area pacing (LBBAP) is a potential supplementary to fluoroscopy-guided implantation and may reduce radiation. Objectives: To evaluate the feasibility and long-term stability of TTE-assisted, low-fluoroscopy LBBAP across different workflows and lead types. Methods: This retrospective study enrolled 45 consecutive patients between November 2021 and June 2022, analyzing 42 successful cases. Patients were stratified by workflow approach (non-scrubbed, n = 24; scrubbed aseptic, n = 18) and lead type (lumen-less leads [LLLs], n = 20; stylet-driven leads [SDLs], n = 22). Procedural and pacing parameters were assessed through a 4-year follow-up. Results: In select patients with adequate acoustic windows, multi-stage TTE-assisted LBBAP remained feasible despite a 54.8% overweight/obesity rate. The scrubbed aseptic workflow showed significantly shorter procedural and fluoroscopy times (p < 0.01), though confounded by the learning curve. Beyond 6 months, pacing parameters remained stable and comparable between workflows through 4 years. Regarding lead types, procedural durations were similar. However, the SDL group exhibited significantly higher pacing thresholds at implant and 6 months (p < 0.05) and maintained a higher numerical trend through Year 4, though both lead types demonstrated stable chronic sensing and impedance profiles. No late dislodgements, device-related infections, or late complications occurred across available patient-years. Conclusions: TTE-assisted LBBAP is a clinically feasible approach that can supplement conventional implantation in selected patients with favorable acoustic windows. While achieving excellent 4-year functional durability, procedural improvements reflect the combined effect of workflow refinement and operator proficiency.
Related
- Feasibility and Safety of Transthoracic Echocardiography–Guided Transvenous Permanent Pacemaker Implantation Without Fluoroscopy
- Transthoracic echocardiography vs. cardiac magnetic resonance imaging for the diagnosis of left ventricular thrombus: an updated systematic review and diagnostic accuracy meta-analysis
- A Single-Center Retrospective Analysis of the Diagnostic Efficacy of Transthoracic Echocardiography in the Classification of Patent Ductus Arteriosus
- Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography
- Exploratory clinical predictors of prolonged hospital stay in patients with patent foramen ovale undergoing transthoracic echocardiography- or X-ray-guided closure
BibTeX
@article{chu2026transthoracic,
title = {{Transthoracic Echocardiography-Assisted, Low-Fluoroscopy Left Bundle Branch Area Pacing: A Comparison of Implantation Approaches and Lead Types.}},
author = {Po-Hua Chu and Chung-Lieh Hung and Kuo-Tzu Sung and Shu-Fen Hsu and Cheng-Ting Tsai and Jen-Yuan Kuo and Sheng-Hsiung Chang},
journal = {Diagnostics (Basel, Switzerland)},
year = {2026},
month = sep,
doi = {10.3390/diagnostics16193172},
url = {https://europepmc.org/article/MED/42882327},
note = {CC BY},
}
RIS
TY - JOUR
TI - Transthoracic Echocardiography-Assisted, Low-Fluoroscopy Left Bundle Branch Area Pacing: A Comparison of Implantation Approaches and Lead Types.
AU - Po-Hua Chu
AU - Chung-Lieh Hung
AU - Kuo-Tzu Sung
AU - Shu-Fen Hsu
AU - Cheng-Ting Tsai
AU - Jen-Yuan Kuo
AU - Sheng-Hsiung Chang
PY - 2026
DA - 2026/09/29
JO - Diagnostics (Basel, Switzerland)
DO - 10.3390/diagnostics16193172
UR - https://europepmc.org/article/MED/42882327
AB - Background: Transthoracic echocardiography (TTE)-assisted left bundle branch area pacing (LBBAP) is a potential supplementary to fluoroscopy-guided implantation and may reduce radiation. Objectives: To evaluate the feasibility and long-term stability of TTE-assisted, low-fluoroscopy LBBAP across different workflows and lead types. Methods: This retrospective study enrolled 45 consecutive patients between November 2021 and June 2022, analyzing 42 successful cases. Patients were stratified by workflow approach (non-scrubbed, n = 24; scrubbed aseptic, n = 18) and lead type (lumen-less leads [LLLs], n = 20; stylet-driven leads [SDLs], n = 22). Procedural and pacing parameters were assessed through a 4-year follow-up. Results: In select patients with adequate acoustic windows, multi-stage TTE-assisted LBBAP remained feasible despite a 54.8% overweight/obesity rate. The scrubbed aseptic workflow showed significantly shorter procedural and fluoroscopy times (p < 0.01), though confounded by the learning curve. Beyond 6 months, pacing parameters remained stable and comparable between workflows through 4 years. Regarding lead types, procedural durations were similar. However, the SDL group exhibited significantly higher pacing thresholds at implant and 6 months (p < 0.05) and maintained a higher numerical trend through Year 4, though both lead types demonstrated stable chronic sensing and impedance profiles. No late dislodgements, device-related infections, or late complications occurred across available patient-years. Conclusions: TTE-assisted LBBAP is a clinically feasible approach that can supplement conventional implantation in selected patients with favorable acoustic windows. While achieving excellent 4-year functional durability, procedural improvements reflect the combined effect of workflow refinement and operator proficiency.
SN - 2075-4418
ER -