Skip to content
DraconiticResearch
Search Sources API
189,280 studies31 sourcesUpdated 37 min ago
Peer-reviewedCC BYArthroscopy techniques

A Simple Knot Technique to Simultaneously Prevent Medial‐Row Suture Loosening and Lateral‐Row Anchor Failure in Double‐Row Rotator Cuff Repair

  1. 1Department of Sports Medicine Panyu Hospital of Traditional Chinese Medicine Panyu Hospital of Guangzhou University of Chinese Medicine, Guangzhou Guangdong China.

Abstract

We describe a simple knot-tying technique to augment fixation during double-row rotator cuff repair. After standard lateral-row anchor placement and suture tensioning, the remaining suture limbs are secured with a surgeon's knot positioned flush against the bone-anchor interface. This knot serves as a mechanical stopper: when the retracted cuff exerts medial traction on the medial-row sutures, the knot blocks suture slippage at the lateral bone surface, generating a counterforce that neutralizes pullout forces and maintains footprint compression. No additional implants are required. This technique is particularly valuable in osteoporotic bone or massive cuff tears, where lateral-row anchor fixation is prone to early failure.

Related

  1. Peri-areolar dermal reinforcement to prevent prosthetic-related complications in prepectoral reconstruction with a compromised nipple-areola complex: a surgical technique
    Joon-Sung Lee, Sang-Oh Lee, Du-Hyong Cho +2
    Gland SurgeryPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Arthroscopic Stabilization of the Hypermobile Lateral Meniscus Using an All‐Inside Repair Technique
    Alberto Grassi, Tosca Cerasoli, Vito Gaetano Rinaldi +3
    Arthroscopy techniquesPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  3. Arthroscopic Saucerization and Anatomic Repair of a Wrisberg Variant Discoid Lateral Meniscus: A Physeal‐Sparing Knotless Anchor Technique
    Stephen Rossettie, Ann Hu, Dan Griffin +2
    Arthroscopy techniquesPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  4. Lateral-Only Flexible Intramedullary Nailing for Pediatric Tibial Shaft Fractures: An Early Comparative Experience With a Novel Technique to Reduce Symptomatic Implant Prominence
    Alan D. Villegas Meza, Matthew Allen, Brendon C. Mitchell +2
    Journal of the Pediatric Orthopaedic Society of North AmericaPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. The “Minimizing Excessive Rotational Instability Technique” (MERI Technique): A Simple Lateral Tenodesis Reconstructing the Condylar Strap, the Distal Kaplan Fibers, and the Femoral Insertion of the Anterolateral Ligament to Control Internal Rotation During Anterior Cruciate Ligament Surgery
    Nicolas Bouguennec, Philippe Colombet, Nicolas Graveleau
    Arthroscopy techniquesPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
BibTeX
@article{wang2026simple,
  title = {{A Simple Knot Technique to Simultaneously Prevent Medial‐Row Suture Loosening and Lateral‐Row Anchor Failure in Double‐Row Rotator Cuff Repair}},
  author = {Weidong Wang and Mu Gao and Yingbiao Wang and Sen Li},
  journal = {Arthroscopy techniques},
  year = {2026},
  month = oct,
  doi = {10.1002/atn2.70370},
  url = {https://europepmc.org/article/PMC/PMC13718697},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - A Simple Knot Technique to Simultaneously Prevent Medial‐Row Suture Loosening and Lateral‐Row Anchor Failure in Double‐Row Rotator Cuff Repair
AU  - Weidong Wang
AU  - Mu Gao
AU  - Yingbiao Wang
AU  - Sen Li
PY  - 2026
DA  - 2026/10/29
JO  - Arthroscopy techniques
DO  - 10.1002/atn2.70370
UR  - https://europepmc.org/article/PMC/PMC13718697
AB  - We describe a simple knot-tying technique to augment fixation during double-row rotator cuff repair. After standard lateral-row anchor placement and suture tensioning, the remaining suture limbs are secured with a surgeon's knot positioned flush against the bone-anchor interface. This knot serves as a mechanical stopper: when the retracted cuff exerts medial traction on the medial-row sutures, the knot blocks suture slippage at the lateral bone surface, generating a counterforce that neutralizes pullout forces and maintains footprint compression. No additional implants are required. This technique is particularly valuable in osteoporotic bone or massive cuff tears, where lateral-row anchor fixation is prone to early failure.
SN  - 2212-6287
ER  -