Case Report: Serial 4D-CT evolution from focal leaflet thickening to multileaflet HALT after transcatheter aortic valve replacement in a hemodialysis patient
5 affiliations
- 1Interventional Cardiology Unit (Interventional Operation Room), Affiliated Hospital of Qingdao University
- 2Department of Nuclear Medicine, Affiliated Hospital of Qingdao University
- 3Department of Cardiology, Affiliated Hospital of Qingdao University
- 4Department of Cardiovascular Surgery, Affiliated Hospital of Qingdao University
- 5Department of Nephrology, Affiliated Hospital of Qingdao University
Abstract
Background: Electrocardiographically gated multiphase cardiac computed tomography (4D-CT) is the reference imaging technique for detecting hypoattenuated leaflet thickening (HALT) and assessing associated leaflet-motion abnormalities after transcatheter aortic valve replacement (TAVR). The significance of an isolated abnormality detected during the first postoperative week remains uncertain.
Case description: A 51-year-old woman receiving maintenance hemodialysis for 13 years underwent transfemoral TAVR with a 23-mm Edwards SAPIEN 3 valve. A visible prosthetic waist was treated by balloon post-dilatation, reducing the invasive transvalvular gradient from 60 to 1 mmHg. Routine postoperative day-7 ECG-gated 4D-CT, reconstructed in 10 phases across the cardiac cycle, showed focal noncoronary cusp thickening measuring 2.5 mm on short-axis and 2.4 mm on long-axis images, with preserved leaflet motion. The immediate post-TAVR mean gradient was 4 mmHg; the nearest early follow-up examination on postoperative day 6 showed a mean gradient of 11 mmHg and a Doppler velocity index of 0.50. Serial echocardiography subsequently showed progressive hemodynamic deterioration. At approximately 7.5 months, limited-phase ECG-gated CT comprising paired systolic and diastolic reconstructions demonstrated multileaflet HALT with predominant right coronary cusp involvement. The abnormal tissue measured approximately 85 HU, extended 14.7 mm longitudinally, reached a maximal thickness of 3.1 mm, and was associated with an estimated 75% reduction in systolic leaflet excursion. The contemporaneous mean gradient was 25 mmHg and increased to 30 mmHg approximately 3 weeks later.
Conclusion: This case documents a temporal sequence from an early focal leaflet abnormality with preserved motion to multileaflet HALT, marked motion restriction, and prosthetic valve hemodynamic deterioration. The sequence supports integrated longitudinal assessment but does not establish that the early focal lesion predicted or caused the subsequent HALT.
Related
- Evolution of Right Ventricular Function and Pulmonary Artery Coupling After Transapical Transcatheter Mitral Valve Replacement
- Surgical aortic valve replacement-level aortotomy for self-expanding transcatheter aortic valve explantation
- Intravascular Ultrasound Guidance for Transcatheter Pulmonary Valve Replacement: A Feasibility Study.
- Clinical Outcomes of Transcatheter Versus Surgical Aortic Valve Replacement in Patients with Pure Native Aortic Regurgitation: A Systematic Review and Meta-Analysis
- Longitudinal Trajectories of the Atherogenic Index of Plasma and Their Associations with Clinical Outcomes After Transcatheter Aortic Valve Replacement
BibTeX
@article{liu2026case,
title = {{Case Report: Serial 4D-CT evolution from focal leaflet thickening to multileaflet HALT after transcatheter aortic valve replacement in a hemodialysis patient}},
author = {Weili Liu and Dacheng Li and Song Liu and Lei Jiang and Yan Xu},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
month = nov,
doi = {10.3389/fcvm.2026.2009688},
url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.2009688/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Case Report: Serial 4D-CT evolution from focal leaflet thickening to multileaflet HALT after transcatheter aortic valve replacement in a hemodialysis patient
AU - Weili Liu
AU - Dacheng Li
AU - Song Liu
AU - Lei Jiang
AU - Yan Xu
PY - 2026
DA - 2026/11/03
JO - Frontiers in Cardiovascular Medicine
DO - 10.3389/fcvm.2026.2009688
UR - https://www.frontiersin.org/articles/10.3389/fcvm.2026.2009688/full
AB - Background: Electrocardiographically gated multiphase cardiac computed tomography (4D-CT) is the reference imaging technique for detecting hypoattenuated leaflet thickening (HALT) and assessing associated leaflet-motion abnormalities after transcatheter aortic valve replacement (TAVR). The significance of an isolated abnormality detected during the first postoperative week remains uncertain. Case description: A 51-year-old woman receiving maintenance hemodialysis for 13 years underwent transfemoral TAVR with a 23-mm Edwards SAPIEN 3 valve. A visible prosthetic waist was treated by balloon post-dilatation, reducing the invasive transvalvular gradient from 60 to 1 mmHg. Routine postoperative day-7 ECG-gated 4D-CT, reconstructed in 10 phases across the cardiac cycle, showed focal noncoronary cusp thickening measuring 2.5 mm on short-axis and 2.4 mm on long-axis images, with preserved leaflet motion. The immediate post-TAVR mean gradient was 4 mmHg; the nearest early follow-up examination on postoperative day 6 showed a mean gradient of 11 mmHg and a Doppler velocity index of 0.50. Serial echocardiography subsequently showed progressive hemodynamic deterioration. At approximately 7.5 months, limited-phase ECG-gated CT comprising paired systolic and diastolic reconstructions demonstrated multileaflet HALT with predominant right coronary cusp involvement. The abnormal tissue measured approximately 85 HU, extended 14.7 mm longitudinally, reached a maximal thickness of 3.1 mm, and was associated with an estimated 75% reduction in systolic leaflet excursion. The contemporaneous mean gradient was 25 mmHg and increased to 30 mmHg approximately 3 weeks later. Conclusion: This case documents a temporal sequence from an early focal leaflet abnormality with preserved motion to multileaflet HALT, marked motion restriction, and prosthetic valve hemodynamic deterioration. The sequence supports integrated longitudinal assessment but does not establish that the early focal lesion predicted or caused the subsequent HALT.
SN - 2297-055X
ER -