Comparative Evaluation of Trueness of Three Intraoral Scanner Technologies in Edentulous Maxillary Ridges
5 affiliations
- 1Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
- 2Department of Pedodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
- 3Faculty of Medicine and Surgery , Kore University of Enna, Enna, Italy
- 4Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India; Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain; Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
- 5Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Yerevan, Armenia
Abstract
Purpose: The aim of the study was to compare the trueness of three intraoral scanner (IOS) technologies – Confocal/Wavefront sampling system (3Shape TRIOS), Active triangulation (Medit i700), and Smart Pixel Sensor/Dynamic depth scanning (Primescan) – in capturing maxillary edentulous ridges with varied anatomical characteristics. Materials and methods: A crossover clinical trial was conducted with 24 fully edentulous maxillary patients. A standardized four-swipe scanning pathway was used, a reference master cast created from polyvinyl siloxane impressions and digitized with a laboratory scanner, and intraoral scans using the three IOS devices in randomized order. Trueness was evaluated by comparing IOS scans to the reference using superimposition technique in Geomagic Control X software. Statistical analysis included multifactorial repeated-measures analysis of variance, with 95% confidence intervals and adjusted pairwise comparisons. Results: Scanner type significantly affected root mean square (RMS) deviation ( P < .001), with Medit i700 showing higher deviations than 3Shape TRIOS and Primescan. Arch form also significantly influenced RMS deviation ( P < .001), with V-shaped arches showing greater deviations, while palatal vault height showed a borderline effect ( P = .050). A significant scanner × arch-form interaction was observed ( P < .001). Conclusion: Scanner type and maxillary arch form significantly influenced scan trueness in fully edentulous maxillary arches, whereas palatal vault height showed a limited effect. Under the standardized scanning protocol, 3Shape TRIOS and Primescan demonstrated lower RMS deviations than Medit i700. Clinical relevance: Scanner technology significantly influences the accuracy of digital impressions in edentulous maxillary arches. Selecting highly accurate scanners may improve the predictability of complete denture fabrication.
Related
- Evaluation of the Position of Impacted Maxillary Canines on Panoramic Radiographs Using Deep Learning with CBCT as the Reference Standard
- Preliminary Clinical Case Series for Evaluation of a Novel Bi-Dimensional Archwire During Miniscrew-Supported En-Masse Retraction of the Maxillary Anterior Teeth.
- Application of spectroscopic and multispectral imaging technologies on the assessment of ready-to-eat pineapple quality: A performance evaluation study of machine learning models generated from two commercial data analytics tools
- Comparative efficacy of different digital technologies in adults with insomnia: a systematic review and network meta-analysis of randomized controlled trials
- Artificial Intelligence and Mobile Health Technologies for Improved Healthcare Access: Design and Pilot Evaluation of an Integrated Digital Health Platform for a Nigerian Teaching Hospital
BibTeX
@article{singh2026comparative,
title = {{Comparative Evaluation of Trueness of Three Intraoral Scanner Technologies in Edentulous Maxillary Ridges}},
author = {Meghan Ranjan Singh and Subhabrata Maiti and Jessy Paulraj and Mario Alberto Alarcón-Sánchez and Cosimo Galletti and Seyed Ali Mosaddad and Artak Heboyan},
journal = {International Dental Journal},
year = {2026},
month = oct,
doi = {10.1016/j.identj.2026.111258},
url = {https://doi.org/10.1016/j.identj.2026.111258},
note = {CC BY},
}
RIS
TY - JOUR
TI - Comparative Evaluation of Trueness of Three Intraoral Scanner Technologies in Edentulous Maxillary Ridges
AU - Meghan Ranjan Singh
AU - Subhabrata Maiti
AU - Jessy Paulraj
AU - Mario Alberto Alarcón-Sánchez
AU - Cosimo Galletti
AU - Seyed Ali Mosaddad
AU - Artak Heboyan
PY - 2026
DA - 2026/10/30
JO - International Dental Journal
DO - 10.1016/j.identj.2026.111258
UR - https://doi.org/10.1016/j.identj.2026.111258
AB - Purpose: The aim of the study was to compare the trueness of three intraoral scanner (IOS) technologies – Confocal/Wavefront sampling system (3Shape TRIOS), Active triangulation (Medit i700), and Smart Pixel Sensor/Dynamic depth scanning (Primescan) – in capturing maxillary edentulous ridges with varied anatomical characteristics. Materials and methods: A crossover clinical trial was conducted with 24 fully edentulous maxillary patients. A standardized four-swipe scanning pathway was used, a reference master cast created from polyvinyl siloxane impressions and digitized with a laboratory scanner, and intraoral scans using the three IOS devices in randomized order. Trueness was evaluated by comparing IOS scans to the reference using superimposition technique in Geomagic Control X software. Statistical analysis included multifactorial repeated-measures analysis of variance, with 95% confidence intervals and adjusted pairwise comparisons. Results: Scanner type significantly affected root mean square (RMS) deviation ( P < .001), with Medit i700 showing higher deviations than 3Shape TRIOS and Primescan. Arch form also significantly influenced RMS deviation ( P < .001), with V-shaped arches showing greater deviations, while palatal vault height showed a borderline effect ( P = .050). A significant scanner × arch-form interaction was observed ( P < .001). Conclusion: Scanner type and maxillary arch form significantly influenced scan trueness in fully edentulous maxillary arches, whereas palatal vault height showed a limited effect. Under the standardized scanning protocol, 3Shape TRIOS and Primescan demonstrated lower RMS deviations than Medit i700. Clinical relevance: Scanner technology significantly influences the accuracy of digital impressions in edentulous maxillary arches. Selecting highly accurate scanners may improve the predictability of complete denture fabrication.
SN - 0020-6539
SN - 1875-595X
ER -