Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BY 4.0Frontiers in Oncology

Diagnostic accuracy of artificial intelligence models in the detection of gastric cancer and early gastric cancer: a systematic review and network meta-analysis

Abstract

BackgroundThis study aimed to evaluate and rank the diagnostic accuracy of different Artificial intelligence (AI) models for GC and EGC detection across imaging modalities through a systematic review and network meta-analysis.MethodsPubMed, Embase, Cochrane Library, and Web of Science were comprehensively searched from inception to September 2026. Studies assessing AI models against histopathological reference standards (endoscopic biopsy or surgical specimens) were included. Four main model categories (traditional machine learning (ML), basic convolutional neural network (CNN), object detection systems (DS), and multimodal deep learning (DL)) and five subcategories (ML, ResNet, Fusion, Det, CNN_other) were compared. Bayesian network meta-analysis was used to estimate pooled sensitivity, specificity, diagnostic odds ratio (DOR), superiority index, and the summary receiver operating characteristic (SROC) curves.Results59 studies were included. In primary analyses, for GC detection, multimodal DL showed the highest SROC area (0.98) and DOR (166.02), followed by basic CNN (SROC, 0.95; DOR, 105.29) and traditional ML (0.87; 35.83). For EGC detection, traditional ML showed the highest point estimates (SROC, 0.91; DOR, 182.13), but these were based on only three studies with wide confidence intervals, and no model category could be reliably ranked as superior. In subcategory analyses, CNN_other showed the highest GC point estimates and ML showed the highest EGC point estimates. Heterogeneity was high (I² > 90% for most DL categories). About 35% of studies had high risk of selection bias, and 8 had high risk of index-test bias, potentially inflating accuracy estimates.ConclusionsThis network meta-analysis revealed that AI models are generally effective in diagnosing GC and EGC. Multimodal DL and non-ResNet CNNs yield the highest point estimates for GC. For EGC, no model category clearly outperformed the others. Traditional ML had numerically higher point estimates, but this result was based on few studies with wide uncertainty. These rankings are limited by substantial heterogeneity, indirect comparisons, and a high prevalence of selection and index-test bias, and should be regarded as hypothesis-generating and require modality-specific validation. Prospective, multicenter head-to-head studies with standardized imaging protocols are needed to validate these findings and guide model selection.Systematic review registrationhttps://www.crd.york.ac.uk/prospero/, identifier CRD420261368020.

Related

  1. Artificial intelligence for pulmonary tuberculosis detection on chest X-ray images: A systematic review and diagnostic accuracy meta-analysis
    S. A. Mahfuz, S. Al Mahfuz, S. K. Roy +2
    medRxivPreprintCC BYFull textMedical imaging & radiologymedRxiv
  2. Artificial Intelligence-Enhanced Electrocardiography for the Detection of Hypertrophic Cardiomyopathy in Athletes: A Systematic Review of Diagnostic Accuracy and External Validity
    Leonardo De Medeiros Quirino, Katia X Duarte, Samia G Pereira +7
    CureusPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
  3. Artificial intelligence for breast arterial calcification detection on mammography: A systematic review of diagnostic accuracy
    A Price Campbell, Leticia Petfield, Eric C Nemec Ii +1
    PLOS Digital HealthPeer-reviewedCC BYFull textCardiovascular medicineMedical imaging & radiologyPLOSEurope PMC
  4. Artificial Intelligence-Based Burn Assessment Demonstrates High Diagnostic Accuracy: Systematic Review and Meta-Analysis
    Emily Uyen Thai, Mina Bahramand, Jordyn Carroll +5
    Plastic and Reconstructive Surgery, Global OpenPeer-reviewedCC BY-NC-NDFull textEpidemiology & public healthDOAJ
  5. From underdiagnosis to scalable screening: Applications of artificial intelligence for vertebral compression fracture detection – a systematic review and meta-analysis of diagnostic performance
    Hsuan-Yu Chen, Linjun Yang, Gwen Wilson +4
    Osteoporosis and sarcopeniaPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{jiang2026diagnostic,
  title = {{Diagnostic accuracy of artificial intelligence models in the detection of gastric cancer and early gastric cancer: a systematic review and network meta-analysis}},
  author = {Nan Jiang and Shaoshuai Yan and Ruikang Liu and Yifan Kang and Yuhan Hao and Yilu Cen and Shaoli Wang and Zhen Liu},
  journal = {Frontiers in Oncology},
  year = {2026},
  month = nov,
  doi = {10.3389/fonc.2026.1947619},
  url = {https://www.frontiersin.org/articles/10.3389/fonc.2026.1947619},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Diagnostic accuracy of artificial intelligence models in the detection of gastric cancer and early gastric cancer: a systematic review and network meta-analysis
AU  - Nan Jiang
AU  - Shaoshuai Yan
AU  - Ruikang Liu
AU  - Yifan Kang
AU  - Yuhan Hao
AU  - Yilu Cen
AU  - Shaoli Wang
AU  - Zhen Liu
PY  - 2026
DA  - 2026/11/12
JO  - Frontiers in Oncology
DO  - 10.3389/fonc.2026.1947619
UR  - https://www.frontiersin.org/articles/10.3389/fonc.2026.1947619
AB  - BackgroundThis study aimed to evaluate and rank the diagnostic accuracy of different Artificial intelligence (AI) models for GC and EGC detection across imaging modalities through a systematic review and network meta-analysis.MethodsPubMed, Embase, Cochrane Library, and Web of Science were comprehensively searched from inception to September 2026. Studies assessing AI models against histopathological reference standards (endoscopic biopsy or surgical specimens) were included. Four main model categories (traditional machine learning (ML), basic convolutional neural network (CNN), object detection systems (DS), and multimodal deep learning (DL)) and five subcategories (ML, ResNet, Fusion, Det, CNN_other) were compared. Bayesian network meta-analysis was used to estimate pooled sensitivity, specificity, diagnostic odds ratio (DOR), superiority index, and the summary receiver operating characteristic (SROC) curves.Results59 studies were included. In primary analyses, for GC detection, multimodal DL showed the highest SROC area (0.98) and DOR (166.02), followed by basic CNN (SROC, 0.95; DOR, 105.29) and traditional ML (0.87; 35.83). For EGC detection, traditional ML showed the highest point estimates (SROC, 0.91; DOR, 182.13), but these were based on only three studies with wide confidence intervals, and no model category could be reliably ranked as superior. In subcategory analyses, CNN_other showed the highest GC point estimates and ML showed the highest EGC point estimates. Heterogeneity was high (I² > 90% for most DL categories). About 35% of studies had high risk of selection bias, and 8 had high risk of index-test bias, potentially inflating accuracy estimates.ConclusionsThis network meta-analysis revealed that AI models are generally effective in diagnosing GC and EGC. Multimodal DL and non-ResNet CNNs yield the highest point estimates for GC. For EGC, no model category clearly outperformed the others. Traditional ML had numerically higher point estimates, but this result was based on few studies with wide uncertainty. These rankings are limited by substantial heterogeneity, indirect comparisons, and a high prevalence of selection and index-test bias, and should be regarded as hypothesis-generating and require modality-specific validation. Prospective, multicenter head-to-head studies with standardized imaging protocols are needed to validate these findings and guide model selection.Systematic review registrationhttps://www.crd.york.ac.uk/prospero/, identifier CRD420261368020.
SN  - 2234-943X
ER  -