Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 18 min ago
Peer-reviewedCC BY-NC-NDJournal of robotic surgery

Clinical outcomes of posterior-stabilized versus cruciate-retaining ANTHEM total knee arthroplasty using imageless robotic-assisted personalized alignment: a retrospective comparative cohort study.

6 affiliations
  1. 1Department of Orthopedic Surgery, Mediclinic City Hospital, Dubai, United Arab Emirates.
  2. 2Orthocure Medical Center, Al Khawaneej St - Mirdif, Dubai, United Arab Emirates.
  3. 3Department of Orthopedic Surgery, Mediclinic City Hospital, Dubai, United Arab Emirates. [email protected].
  4. 4Orthocure Medical Center, Al Khawaneej St - Mirdif, Dubai, United Arab Emirates. [email protected].
  5. 5Stockholm Sports Trauma Research Center, Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
  6. 6Rashid Hospital Trauma Centre, Dubai, United Arab Emirates.

Abstract

Posterior-stabilized (PS) and cruciate-retaining (CR) total knee arthroplasty (TKA) show no consistent clinical superiority. This study compared 2-year patient-reported outcomes, responder rates, complications, and revisions between PS and CR ANTHEM TKA using imageless robotic-assisted personalized alignment. This retrospective cohort included 858 primary ANTHEM TKAs (167 CR and 691 PS). All procedures used CORI robotic-assisted personalized alignment. Outcomes included the Knee injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR), visual analog scale (VAS) pain, satisfaction, and general health scores. Entropy-balanced inverse probability weighting adjusted for baseline differences. Responder rates and time to patient acceptable symptom state (PASS) were evaluated. After weighting, measured covariates were balanced and KOOS-JR improved substantially in both groups and did not differ at any postoperative time point. At 1 year, adjusted KOOS-JR scores were 84.1 for CR and 84.7 for PS (difference, - 0.61; 95% CI, - 2.80 to 1.58; p = .58); at 2 years, scores were 86.4 and 86.7, respectively (difference, - 0.38; 95% CI, - 2.31 to 1.55; p = .70). VAS pain, general health, satisfaction, and responder rates were also similar after multiplicity correction. CR patients achieved PASS earlier, but both groups exceeded 99% by 2 years. Complications occurred in 2 CR cases (1.2%) and 7 PS cases (1.0%); revisions occurred in 0 and 6 cases (0.9%), respectively. Using imageless robotic-assisted personalized alignment, CR and PS ANTHEM TKA produced substantial and comparable improvements in pain and patient-reported outcomes. CR was associated with earlier PASS achievement, but final outcomes and short-term complication and revision rates did not differ significantly.

Related

  1. Comparable clinical outcomes but different postoperative Dynamic Alignment of the Knee (DyAK) patterns between cruciate-retaining and posterior-stabilized inserts in functionally aligned robotic-assisted total knee arthroplasty.
    Christos Koutserimpas, Enejd Veizi, Sébastien Lustig +1
    Journal of experimental orthopaedicsPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMCHAL
  2. Glenoid inclination in reverse total shoulder arthroplasty with and without baseplate wedge augmentation: a retrospective comparative study
    Riki D. Wylie, Clement Chan, Jay R. Ebert +1
    Journal of shoulder and elbow arthroplastyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  3. Impact of Suture Configurations for Posterior Horn Meniscal Repair on Postoperative Stability and Reoperation Rates in Patients Undergoing Concurrent Anterior Cruciate Ligament Reconstruction: A Retrospective Comparative Study
    Yongwei Song, Kexin Cai, Jiachao Qiu +3
    Indian journal of orthopaedicsPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  4. Surgical approach and insert constraint are associated with small differences in patellar tilt after robotic‐assisted total knee arthroplasty: A retrospective comparative radiographic study
    Clément Favroul, Mehdi Drissi Kaitouni, Elvire Servien +2
    Journal of Experimental OrthopaedicsPeer-reviewedCC BYFull textSurgery & anaesthesiaHAL
  5. Comparison of immediate post-operative pain and functional outcomes of surgeon-administered adductor canal block through subvastus versus medial parapatellar approach in total knee arthroplasty: A retrospective comparative study.
    Akash Saraogi, Vishnu Jayaprakasan, Hasan Jhanjharya
    Journal of orthopaedic case reportsPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaEurope PMCPMC
BibTeX
@article{albelooshi2026clinical,
  title = {{Clinical outcomes of posterior-stabilized versus cruciate-retaining ANTHEM total knee arthroplasty using imageless robotic-assisted personalized alignment: a retrospective comparative cohort study.}},
  author = {Ali Albelooshi and Elhadi Babikir and Zainab Aqeel Khan and Abdallah Reda Bedair Elgouhary and Saeed Al Thani},
  journal = {Journal of robotic surgery},
  year = {2026},
  month = nov,
  doi = {10.1007/s11701-026-04219-2},
  url = {https://europepmc.org/article/MED/43079134},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Clinical outcomes of posterior-stabilized versus cruciate-retaining ANTHEM total knee arthroplasty using imageless robotic-assisted personalized alignment: a retrospective comparative cohort study.
AU  - Ali Albelooshi
AU  - Elhadi Babikir
AU  - Zainab Aqeel Khan
AU  - Abdallah Reda Bedair Elgouhary
AU  - Saeed Al Thani
PY  - 2026
DA  - 2026/11/25
JO  - Journal of robotic surgery
DO  - 10.1007/s11701-026-04219-2
UR  - https://europepmc.org/article/MED/43079134
AB  - Posterior-stabilized (PS) and cruciate-retaining (CR) total knee arthroplasty (TKA) show no consistent clinical superiority. This study compared 2-year patient-reported outcomes, responder rates, complications, and revisions between PS and CR ANTHEM TKA using imageless robotic-assisted personalized alignment. This retrospective cohort included 858 primary ANTHEM TKAs (167 CR and 691 PS). All procedures used CORI robotic-assisted personalized alignment. Outcomes included the Knee injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR), visual analog scale (VAS) pain, satisfaction, and general health scores. Entropy-balanced inverse probability weighting adjusted for baseline differences. Responder rates and time to patient acceptable symptom state (PASS) were evaluated. After weighting, measured covariates were balanced and KOOS-JR improved substantially in both groups and did not differ at any postoperative time point. At 1 year, adjusted KOOS-JR scores were 84.1 for CR and 84.7 for PS (difference, - 0.61; 95% CI, - 2.80 to 1.58; p = .58); at 2 years, scores were 86.4 and 86.7, respectively (difference, - 0.38; 95% CI, - 2.31 to 1.55; p = .70). VAS pain, general health, satisfaction, and responder rates were also similar after multiplicity correction. CR patients achieved PASS earlier, but both groups exceeded 99% by 2 years. Complications occurred in 2 CR cases (1.2%) and 7 PS cases (1.0%); revisions occurred in 0 and 6 cases (0.9%), respectively. Using imageless robotic-assisted personalized alignment, CR and PS ANTHEM TKA produced substantial and comparable improvements in pain and patient-reported outcomes. CR was associated with earlier PASS achievement, but final outcomes and short-term complication and revision rates did not differ significantly.
SN  - 1863-2483
SN  - 1863-2491
ER  -