Real-time algorithm-driven ventilation feedback to improve lung-protective ventilation in patients with ARDS (REALVENT-study): study protocol for a multicentre randomised controlled trial
16 affiliations
- 1Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
- 2School of Population Medicine and Public Health, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, 100730 China
- 3Department of Intensive Care Unit, Qujing Central Hospital of Yunnan Province, Qujing, China
- 4Anesthesia and Critical Care Department B, Saint Eloi Teaching Hospital, PhyMedExp, University of Montpellier, INSERM U1046, Montpellier, France
- 5Department of Automation, Tsinghua University, Beijing, China
- 6Department of Critical Care Medicine, Chongqing Academy of Medical Sciences, Chongqing General Hospital, Chongqing University, Chongqing, China
- 7Department of Citical Care Medicine, Shandong Provincial Hospital, Jinan, China
- 8Department of Citical Care Medicine, Henan Provincial People’s Hospital, Zhenzhou, China
- 9Department of Citical Care Medicine, Hepingli Hospital, Beijing, China
- 10Department of Citical Care Medicine, Binzhou Second People’s Hospital, Binzhou, China
- 11Department of Citical Care Medicine, Beijing Sixth Hospital, Beijing, China
- 12Beijing Anzhen Nanchong Hospital, Capital Medical University & Nanchong Central Hospital, Nanchong, China
- 13Intensive Care Unit, The First Affiliated Hospital of Jinzhou Medical University, Jinzhou, Liaoning Province, China
- 14Shanghai Shumu Medical Technology Co., Ltd, Shanghai, China
- 15Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA USA
- 16Division of Pulmonary and Critical Care Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA USA
Abstract
Background: Lung-protective ventilation is a cornerstone of modern mechanical ventilation, yet real-world adherence to lung-protective targets remains suboptimal. While previous studies have established the physiological benefits of low tidal volume and driving pressure, clinical implementation is hindered by limited monitoring granularity and lack of real-time actionable feedback. This trial aims to evaluate whether a real-time, cloud-based algorithmic feedback platform can improve lung-protective ventilation delivery and contribute to better clinical outcomes in mechanically ventilated patients with ARDS.
Methods: This multicentre, parallel-group, open-label randomised controlled trial will enrol 208 adult mechanically ventilated ICU patients with ARDS from nine adult ICUs across tertiary academic hospitals and regional referral centres in multiple provinces and municipalities in mainland China. Participants will be randomly assigned in blocks to receive either standard monitoring (Control group) or real-time respiratory mechanics feedback through a cloud-based platform (Intervention group). The intervention group will receive real-time alerts for lasting 72 h and ventilator reports every 24 h, integrating tidal volume, plateau pressure, driving pressure, mechanical power, and detected patient–ventilator asynchrony events. The primary outcome is the lung-protective ventilation achievement rate, defined as compliance with VT < 8 mL/kg predicted body weight, driving pressure < 15 cmH₂O, plateau pressure < 30 cmH₂O, and mechanical power < 17 J/min during the first 72 h after randomisation. Secondary outcomes include ventilator-free days at day 28, ICU length of stay, ventilator-associated complications, inflammatory biomarkers, clinician satisfaction, and predefined safety outcomes, including severe hypoxemia, severe hypercapnia/acidemia, barotrauma, and hemodynamic instability temporally associated with ventilator adjustments.
Discussion: This study is, to our knowledge, among the first multicentre randomised controlled trials to evaluate a real-time algorithmic feedback platform designed to enhance lung-protective ventilation. The intervention is designed to provide continuous bedside feedback on ventilation mechanics and may enable more timely and standardised clinical adjustments, with the potential to facilitate lung-protective ventilation delivery.
Triaiontl registration
ClinicalTrials.gov Identifier NCT07307066 (Registration Date: 2025/12/02).
Related
- Effect of intraoperative high positive end-expiratory pressure with recruitment manoeuvres versus low positive end-expiratory pressure on postoperative lung function in obese adults: a substudy of the protective ventilation in obese patients randomised controlled trial
- Photobiomodulation therapy combined with a static magnetic field in critically ill patients receiving invasive mechanical ventilation: protocol for a multicentre randomised triple-blind placebo-controlled trial.
- Outpatient follow-up of COPD patients undergoing long-term noninvasive ventilation (OCONIV): a randomised, controlled, multicentre trial
- Association between invasive mechanical ventilation and acute kidney injury in critically ill patients: a protocol for a systematic review and meta-analysis of randomised controlled trials.
- Immobilisation versus early active motion following primary flexor pollicis longus tendon zones 1-2 repair: protocol for a registry-based multicentre randomised controlled trial in Sweden.
BibTeX
@article{su2026realtime,
title = {{Real-time algorithm-driven ventilation feedback to improve lung-protective ventilation in patients with ARDS (REALVENT-study): study protocol for a multicentre randomised controlled trial}},
author = {Longxiang Su and Yingying Yang and Ye Wang and Jinyan Lan and Chaofu Yue and Mei Yang and Joris Pensier and Song Zhang and Jin Yang and Jicheng Zhang and Huanzhang Shao and Yu Wang and Jiangyong Zhao and Xiaojun Song and Haiquan Cao and Huiping Wu and Fuhong Cai and Yue Ma and Zhangwei Song and Daniel Talmor and Elias Baedorf-Kassis and Yun Long},
journal = {Respiratory Research},
year = {2026},
month = jul,
doi = {10.1186/s12931-026-03766-4},
url = {https://doi.org/10.1186/s12931-026-03766-4},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Real-time algorithm-driven ventilation feedback to improve lung-protective ventilation in patients with ARDS (REALVENT-study): study protocol for a multicentre randomised controlled trial
AU - Longxiang Su
AU - Yingying Yang
AU - Ye Wang
AU - Jinyan Lan
AU - Chaofu Yue
AU - Mei Yang
AU - Joris Pensier
AU - Song Zhang
AU - Jin Yang
AU - Jicheng Zhang
AU - Huanzhang Shao
AU - Yu Wang
AU - Jiangyong Zhao
AU - Xiaojun Song
AU - Haiquan Cao
AU - Huiping Wu
AU - Fuhong Cai
AU - Yue Ma
AU - Zhangwei Song
AU - Daniel Talmor
AU - Elias Baedorf-Kassis
AU - Yun Long
PY - 2026
DA - 2026/07/04
JO - Respiratory Research
DO - 10.1186/s12931-026-03766-4
UR - https://doi.org/10.1186/s12931-026-03766-4
AB - Background: Lung-protective ventilation is a cornerstone of modern mechanical ventilation, yet real-world adherence to lung-protective targets remains suboptimal. While previous studies have established the physiological benefits of low tidal volume and driving pressure, clinical implementation is hindered by limited monitoring granularity and lack of real-time actionable feedback. This trial aims to evaluate whether a real-time, cloud-based algorithmic feedback platform can improve lung-protective ventilation delivery and contribute to better clinical outcomes in mechanically ventilated patients with ARDS. Methods: This multicentre, parallel-group, open-label randomised controlled trial will enrol 208 adult mechanically ventilated ICU patients with ARDS from nine adult ICUs across tertiary academic hospitals and regional referral centres in multiple provinces and municipalities in mainland China. Participants will be randomly assigned in blocks to receive either standard monitoring (Control group) or real-time respiratory mechanics feedback through a cloud-based platform (Intervention group). The intervention group will receive real-time alerts for lasting 72 h and ventilator reports every 24 h, integrating tidal volume, plateau pressure, driving pressure, mechanical power, and detected patient–ventilator asynchrony events. The primary outcome is the lung-protective ventilation achievement rate, defined as compliance with VT < 8 mL/kg predicted body weight, driving pressure < 15 cmH₂O, plateau pressure < 30 cmH₂O, and mechanical power < 17 J/min during the first 72 h after randomisation. Secondary outcomes include ventilator-free days at day 28, ICU length of stay, ventilator-associated complications, inflammatory biomarkers, clinician satisfaction, and predefined safety outcomes, including severe hypoxemia, severe hypercapnia/acidemia, barotrauma, and hemodynamic instability temporally associated with ventilator adjustments. Discussion: This study is, to our knowledge, among the first multicentre randomised controlled trials to evaluate a real-time algorithmic feedback platform designed to enhance lung-protective ventilation. The intervention is designed to provide continuous bedside feedback on ventilation mechanics and may enable more timely and standardised clinical adjustments, with the potential to facilitate lung-protective ventilation delivery. Triaiontl registration ClinicalTrials.gov Identifier NCT07307066 (Registration Date: 2025/12/02).
SN - 1465-9921
SN - 1465-993X