Indocyanine green fluorescence-guided TAPP for recurrent inguinal hernia: a technical note with case series
- 1Department of General Surgery, Handan Central Hospital, Handan, Hebei Province, China
- 2Department of Nursing, Handan Central Hospital, Handan, Hebei Province, China
- 3Department of Internal Medicine, Qiu County People’s Hospital, Handan, Hebei Province, China
Abstract
Introduction and importance: Laparoscopic transabdominal preperitoneal (TAPP) repair for recurrent inguinal hernias carries a nonnegligible risk of injury to the corona mortis, spermatic vessels, and inguinal nerves because of adhesions and distorted anatomy. Indocyanine green (ICG) fluorescence imaging enables real-time visualization of vascular structures, but no standardized application protocol exists for this specific setting. We describe our technique and early experience with ICG guided TAPP in recurrent hernia patients.
Presentation of cases: We retrospectively analyzed 14 patients with recurrent inguinal hernia who underwent ICG fluorescenceguided TAPP between January 2023 and June 2025. All procedures were performed by a single surgeon using a 4 K fluorescence laparoscopy system. Indocyanine green (2.5 mg per dose) was administered intravenously at key steps—typically after peritoneal opening, during sac mobilization, and before mesh fixation—based on the surgeon's assessment of anatomical clarity. Fluorescence imaging was used to identify the inferior epigastric vessels, corona mortis, spermatic vessels, peri-vas deferens venous plexus, and nerve-adjacent vessels. Mean operative time was 55.9 ± 6.1 min. Mean blood loss was 7.2 ± 2.6 mL. The corona mortis was visualized in 13 of 14 cases (92.9%). No vascular injuries or chronic pain were observed during 6 month follow up. Two minor complications occurred (one seroma, one foreign body sensation).
Clinical discussion: ICG fluorescence reliably identified key structures in all cases, with consistent visualization occurring 40–60s after injection. The technique was particularly valuable for delineating the corona mortis and the vascular bundles accompanying the iliohypogastric and ilioinguinal nerves, providing real-time visualization of these structures during dissection and mesh fixation. The learning curve for incorporating ICG into the standard TAPP workflow was minimal, and no ICGrelated adverse events occurred.
Conclusion: ICG fluorescence is a safe and feasible adjunct in recurrent inguinal hernia TAPP. It provides real-time anatomical guidance that may assist in identifying these structures during dissection and mesh fixation. We propose a reproducible injection sequence that can be incorporated into the existing TAPP steps as a practical reference. Larger studies with longer follow-up are needed to confirm long-term outcomes.
Related
- Indocyanine green fluorescence-guided surgery in acute settings: state-of-the art
- Indocyanine green fluorescence–guided laparoscopic anatomical hepatectomy for radical resection of hepatocellular carcinoma: a clinical study
- Second-Window Indocyanine Green fluorescence imaging differentiates inflammation from necrotic tissue in early burn wounds
- The Role of Intraoperative Indocyanine Green Fluorescence Angiography in Reducing Anastomotic Leak After Colorectal Resection: A Systematic Review of Randomised Controlled Trials
- Optimizing Indocyanine Green Fluorescence Cholangiography in Laparoscopic Cholecystectomy: A Systematic Review of Randomized Controlled Trials on Dose, Timing, Route, Efficacy, and Safety
BibTeX
@article{huang2026indocyanine,
title = {{Indocyanine green fluorescence-guided TAPP for recurrent inguinal hernia: a technical note with case series}},
author = {Qianpeng Huang and Lihua Zhao and Jiandong Yin and An Yang and Hongbo Liu},
journal = {Frontiers in Surgery},
year = {2026},
month = oct,
doi = {10.3389/fsurg.2026.1985635},
url = {https://doi.org/10.3389/fsurg.2026.1985635},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Indocyanine green fluorescence-guided TAPP for recurrent inguinal hernia: a technical note with case series
AU - Qianpeng Huang
AU - Lihua Zhao
AU - Jiandong Yin
AU - An Yang
AU - Hongbo Liu
PY - 2026
DA - 2026/10/21
JO - Frontiers in Surgery
DO - 10.3389/fsurg.2026.1985635
UR - https://doi.org/10.3389/fsurg.2026.1985635
AB - Introduction and importance: Laparoscopic transabdominal preperitoneal (TAPP) repair for recurrent inguinal hernias carries a nonnegligible risk of injury to the corona mortis, spermatic vessels, and inguinal nerves because of adhesions and distorted anatomy. Indocyanine green (ICG) fluorescence imaging enables real-time visualization of vascular structures, but no standardized application protocol exists for this specific setting. We describe our technique and early experience with ICG guided TAPP in recurrent hernia patients. Presentation of cases: We retrospectively analyzed 14 patients with recurrent inguinal hernia who underwent ICG fluorescenceguided TAPP between January 2023 and June 2025. All procedures were performed by a single surgeon using a 4 K fluorescence laparoscopy system. Indocyanine green (2.5 mg per dose) was administered intravenously at key steps—typically after peritoneal opening, during sac mobilization, and before mesh fixation—based on the surgeon's assessment of anatomical clarity. Fluorescence imaging was used to identify the inferior epigastric vessels, corona mortis, spermatic vessels, peri-vas deferens venous plexus, and nerve-adjacent vessels. Mean operative time was 55.9 ± 6.1 min. Mean blood loss was 7.2 ± 2.6 mL. The corona mortis was visualized in 13 of 14 cases (92.9%). No vascular injuries or chronic pain were observed during 6 month follow up. Two minor complications occurred (one seroma, one foreign body sensation). Clinical discussion: ICG fluorescence reliably identified key structures in all cases, with consistent visualization occurring 40–60s after injection. The technique was particularly valuable for delineating the corona mortis and the vascular bundles accompanying the iliohypogastric and ilioinguinal nerves, providing real-time visualization of these structures during dissection and mesh fixation. The learning curve for incorporating ICG into the standard TAPP workflow was minimal, and no ICGrelated adverse events occurred. Conclusion: ICG fluorescence is a safe and feasible adjunct in recurrent inguinal hernia TAPP. It provides real-time anatomical guidance that may assist in identifying these structures during dissection and mesh fixation. We propose a reproducible injection sequence that can be incorporated into the existing TAPP steps as a practical reference. Larger studies with longer follow-up are needed to confirm long-term outcomes.
SN - 2296-875X
ER -