Skip to content
DraconiticResearch
Search Sources API
190,869 studies31 sourcesUpdated 52 min ago
Peer-reviewedCC BYJournal of applied clinical medical physics

Vision and implementation for the first U.S. carbon ion therapy center part II: Design philosophy and clinical implementation.

  1. 1Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, USA.

Abstract

The anticipated clinical demand for carbon ion radiotherapy (CIRT) in the United States is expected to include a substantial proportion of clinically complex disease sites that require accurate, highly conformal, and adaptive treatment. These clinical needs, together with the unique physical and biological characteristics of carbon ion beams, form the foundation of the design philosophy for the Mayo Clinic Florida (MCF) CIRT program. The program remains under active development, with clinical deployment planned for 2028. Building upon the clinical rationale and anticipated U.S. patient population discussed in Part I of this two-part review, this Vision Article describes how MCF intends to develop an integrated CIRT treatment system. The program is guided by two overarching principles: fast, accurate, and safe beam delivery and accurate treatment planning and treatment delivery, supported by an integrated patient-specific quality assurance framework. Key elements include high-dose-rate dose-driven continuous scanning with advanced beam monitoring and irradiation control, delivery-aware treatment planning, the Monte Carlo-based BioPhys computational platform integrating physical and biological dose modeling, a hierarchical adaptive workflow, and patient-specific quality assurance spanning pretreatment, on-treatment, and post-treatment verification. This framework provides a technical roadmap for the integrated clinical implementation of CIRT at MCF.

Related

  1. Vision and implementation for the first U.S. carbon ion therapy center part I: Clinical rationale and the need for CIRT in the United States.
    Xiaoying Liang, Chris J Beltran
    Journal of applied clinical medical physicsPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  2. Rhythmic dance interventions and dance/movement therapy for depression and anxiety: a structured narrative review of clinical evidence, candidate mechanisms, and implementation considerations
    Xiaopeng Chen, Ting Wang, Jun Wang +1
    Frontiers in PsychiatryPeer-reviewedCC BY 4.0Full textPsychiatry & mental healthCrossrefEurope PMCEurope PMCPMC
  3. Cytomegalovirus Retinitis Across the Immunosuppression Spectrum: A Contemporary Framework for Risk Stratification, Diagnosis, and Vision-Preserving Therapy
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Development and pilot implementation of CERMATA: A digital referral-based vision screening platform for Indonesian primary school children
    Kianti Raisa Darusman, Alicia Kartika, Christella Caroline +4
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePhysiologyPLOS
  5. Computer vision, Parkinson’s disease, and the unfinished work of clinical translation
    Jane Alty, Maximilian U. Friedrich
    npj Parkinson's DiseasePeer-reviewedCC BYFull textNeurologyDOAJ
BibTeX
@article{liang2026vision,
  title = {{Vision and implementation for the first U.S. carbon ion therapy center part II: Design philosophy and clinical implementation.}},
  author = {Xiaoying Liang and Chris J Beltran},
  journal = {Journal of applied clinical medical physics},
  year = {2026},
  month = oct,
  doi = {10.1002/acm2.70866},
  url = {https://europepmc.org/article/MED/42900563},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Vision and implementation for the first U.S. carbon ion therapy center part II: Design philosophy and clinical implementation.
AU  - Xiaoying Liang
AU  - Chris J Beltran
PY  - 2026
DA  - 2026/10/30
JO  - Journal of applied clinical medical physics
DO  - 10.1002/acm2.70866
UR  - https://europepmc.org/article/MED/42900563
AB  - The anticipated clinical demand for carbon ion radiotherapy (CIRT) in the United States is expected to include a substantial proportion of clinically complex disease sites that require accurate, highly conformal, and adaptive treatment. These clinical needs, together with the unique physical and biological characteristics of carbon ion beams, form the foundation of the design philosophy for the Mayo Clinic Florida (MCF) CIRT program. The program remains under active development, with clinical deployment planned for 2028. Building upon the clinical rationale and anticipated U.S. patient population discussed in Part I of this two-part review, this Vision Article describes how MCF intends to develop an integrated CIRT treatment system. The program is guided by two overarching principles: fast, accurate, and safe beam delivery and accurate treatment planning and treatment delivery, supported by an integrated patient-specific quality assurance framework. Key elements include high-dose-rate dose-driven continuous scanning with advanced beam monitoring and irradiation control, delivery-aware treatment planning, the Monte Carlo-based BioPhys computational platform integrating physical and biological dose modeling, a hierarchical adaptive workflow, and patient-specific quality assurance spanning pretreatment, on-treatment, and post-treatment verification. This framework provides a technical roadmap for the integrated clinical implementation of CIRT at MCF.
SN  - 1526-9914
ER  -