Development and qualification of quantitative assays for detecting process-related nucleic acid impurities in recombinant AAV preparations
- 1National Institute of Biology, Večna Pot 121, 1000 Ljubljana, Slovenia
Abstract
Residual DNA impurities in recombinant adeno-associated virus (rAAV) vector preparations pose an important analytical and regulatory challenge, yet current methods provide limited information on their integrity. Here, we developed multiplex digital PCR (dPCR) workflows that quantitatively distinguish full-length from fragmented DNA impurities originating from plasmid backbones (ampicillin and kanamycin resistance genes) and host-cell DNA (adenoviral E1A and SV40 large T antigen). By strategically positioning terminal and internal assays across each target, the method enables integrity assessment beyond the capabilities of other methods. In our CsCl-purified scAAV9 preparations, plasmid-derived sequences were abundant and largely DNase I resistant, confirming their encapsidation, whereas host-cell-derived impurities were present at low levels and mostly removed by nuclease treatment. Obtained dPCR results were further confirmed using countable PCR, a recently introduced single-molecule quantification technology, and with nanopore sequencing. Moreover, countable PCR platform was shown to be less sensitive to the highly concentrated AAV background, when quantifying rare targets. Overall, our results demonstrate that multiplex dPCR is an informative tool for integrity profiling of impurities in rAAV manufacturing.
Related
- Development and diagnostic validation of a recombinant Hexon L1-based indirect enzyme-linked immunosorbent assay for detecting antibodies to fowl adenovirus serotype 8b in chickens.
- ALIGN: A modular framework for quantitative analysis of longitudinal development in Caenorhabditis elegans
- Design to Dose: Integrating Quantitative Insights Across the Antibody Drug Conjugate (ADC) Development Lifecycle
- Biologic activities of various thymus preparations
- Exploratory Proteomics of Brain Extracellular Vesicle Enriched Preparations After LPS Challenge and miRNA Associated Vesicle Administration
BibTeX
@article{janc2026development,
title = {{Development and qualification of quantitative assays for detecting process-related nucleic acid impurities in recombinant AAV preparations}},
author = {Mojca Janc and David Dobnik},
journal = {Molecular therapy. Advances},
year = {2026},
month = sep,
doi = {10.1016/j.omta.2026.201854},
url = {https://europepmc.org/article/PMC/PMC13720811},
note = {CC BY},
}
RIS
TY - JOUR
TI - Development and qualification of quantitative assays for detecting process-related nucleic acid impurities in recombinant AAV preparations
AU - Mojca Janc
AU - David Dobnik
PY - 2026
DA - 2026/09/30
JO - Molecular therapy. Advances
DO - 10.1016/j.omta.2026.201854
UR - https://europepmc.org/article/PMC/PMC13720811
AB - Residual DNA impurities in recombinant adeno-associated virus (rAAV) vector preparations pose an important analytical and regulatory challenge, yet current methods provide limited information on their integrity. Here, we developed multiplex digital PCR (dPCR) workflows that quantitatively distinguish full-length from fragmented DNA impurities originating from plasmid backbones (ampicillin and kanamycin resistance genes) and host-cell DNA (adenoviral E1A and SV40 large T antigen). By strategically positioning terminal and internal assays across each target, the method enables integrity assessment beyond the capabilities of other methods. In our CsCl-purified scAAV9 preparations, plasmid-derived sequences were abundant and largely DNase I resistant, confirming their encapsidation, whereas host-cell-derived impurities were present at low levels and mostly removed by nuclease treatment. Obtained dPCR results were further confirmed using countable PCR, a recently introduced single-molecule quantification technology, and with nanopore sequencing. Moreover, countable PCR platform was shown to be less sensitive to the highly concentrated AAV background, when quantifying rare targets. Overall, our results demonstrate that multiplex dPCR is an informative tool for integrity profiling of impurities in rAAV manufacturing.
SN - 3117-387X
ER -