Skip to content
DraconiticResearch
Search Sources API
226,742 studies31 sourcesUpdated 56 min ago
Peer-reviewedCC BY-NC-ND 4.0Lasers in Medical Science

Endoscopic NIRAF-LSCI multimodal system with pseudo-color visualization for parathyroid autofluorescence localization and tissue perfusion assessment: preclinical validation

6 affiliations
  1. 1Guangzhou Medical University, Guangzhou, China
  2. 2The Fifth Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
  3. 3Hunan Institute of Technology, Hengyang, China
  4. 4Chinese Academy of Sciences, Dalian, China
  5. 5Dalian Maritime University, Dalian, China
  6. 6Huakeying Medical Technology (Guangzhou) Co., Ltd., Guangzhou, China

Abstract

Postoperative hypoparathyroidism remains a prevalent complication of thyroid surgery, primarily caused by unrecognized parathyroid gland (PG) injury or devascularization. While near-infrared autofluorescence (NIRAF) enables accurate PG localization, it provides no functional perfusion information; conversely, laser speckle contrast imaging (LSCI) offers label-free real-time perfusion assessment. Herein, we validated a multimodal endoscopic system integrating NIRAF and LSCI for simultaneous PG identification and vascular evaluation, focusing on LSCI perfusion performance and the clinical practicability of its pseudo-color semi-quantitative visualization. The system was tested in 8 Sprague–Dawley rats, where rat thyroids with homologous blood supply served as perfusion surrogates due to the minute volume of rat PGs. Imaging was performed under three strictly controlled in situ conditions: intact native vascularization, partial vascular occlusion, and complete vascular occlusion. LSCI pseudo-color visualization was generated via a standardized pipeline including temporal laser speckle contrast analysis (tLASCA)-based blood flow index (BFI) calculation, baseline-anchored joint 5th–95th percentile normalization, and Jet colormap mapping. Intraoperative probe-based quantitative NIRAF was used to validate NIRAF-visual signal foci. NIRAF clearly identified PGs with a fluorescence intensity of 149.8 ± 8.7 mV, significantly higher than thyroid (93.8 ± 8.0 mV), trachea (84.6 ± 9.1 mV), and muscle (66.3 ± 10.4 mV) (all P < 0.001), achieving 100% positive predictive value (PPV) and 100% negative predictive value (NPV), with zero false-positive findings among all NIRAF-visual foci. PPV was determined using both probe-based NIRAF and histopathology as dual validation references, whereas NPV was determined using postoperative histopathology alone as the reference standard. LSCI speckle contrast increased progressively with decreasing perfusion, with speckle contrast values mapped to a continuous blue-to-red real-time pseudo-color perfusion visualization. Histopathology confirmed all fluorescent tissues as PGs. This multimodal system targets two core clinical needs for intraoperative PG protection, and its standardized pseudo-color semi-quantitative workflow provides real-time label-free perfusion visualization. It shows potential to serve as an intraoperative adjunct to guide parathyroid preservation decisions and reduce reliance on delayed hormonal test results.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10103-026-05092-z.

Related

  1. Does parathyroid autofluorescence reduces unintentional parathyroidectomy during total thyroidectomy with central lymph node compartment dissection?
    Angeliki Chorti, Ioannis Pliakos, Moysis Moysidis +2
    Updates in SurgeryPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  2. Association of intraoperative mitoxantrone hydrochloride injection with incidental parathyroidectomy and parathyroid autotransplantation during gasless unilateral axillary endoscopic thyroidectomy: a propensity score-matched retrospective cohort study
    Qi Jiang, Yaozong Wang, Ziyan Wang +6
    Gland SurgeryPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Near-infrared autofluorescence to differentiate pituitary gland from tumor in endoscopic endonasal resection of pituitary adenomas: illustrative cases
    John E. Phay, Rodrigo Gehrke, Kara A. Parikh +2
    Journal of Neurosurgery: Case LessonsPeer-reviewedCC BY-NC-ND 4.0Full textEndocrinology & metabolismPMC
  4. Improved Visualization of the Internal Branch of the Superior Laryngeal Nerve during Pharyngeal Endoscopic Subepithelial Dissection with Use of Red Dichromatic Imaging
    Yukihisa Fujinaga, Yoshiki Tamada, Yohei Yamaguchi +7
    DEN OpenPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  5. Anchored Drill-Assisted Localization for Percutaneous Endoscopic Cervical Keyhole Surgery in the Treatment of Cervical Spondylotic Radiculopathy: A Technical Report and Preliminary Efficacy Evaluation
    Zhuangzhuang Tan, Bin Xie, Jiajun Cheng +4
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{cai2026endoscopic,
  title = {{Endoscopic NIRAF-LSCI multimodal system with pseudo-color visualization for parathyroid autofluorescence localization and tissue perfusion assessment: preclinical validation}},
  author = {Chang Cai and Chuoqi Yang and Wanyu Sun and Qiye Wen and Xiao Xiao and Dianxin Zhou and Zifeng Luo and Chao Zheng and Xuhui Geng and Zhenhao Liang and Song Wang},
  journal = {Lasers in Medical Science},
  year = {2026},
  month = nov,
  doi = {10.1007/s10103-026-05092-z},
  url = {https://doi.org/10.1007/s10103-026-05092-z},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Endoscopic NIRAF-LSCI multimodal system with pseudo-color visualization for parathyroid autofluorescence localization and tissue perfusion assessment: preclinical validation
AU  - Chang Cai
AU  - Chuoqi Yang
AU  - Wanyu Sun
AU  - Qiye Wen
AU  - Xiao Xiao
AU  - Dianxin Zhou
AU  - Zifeng Luo
AU  - Chao Zheng
AU  - Xuhui Geng
AU  - Zhenhao Liang
AU  - Song Wang
PY  - 2026
DA  - 2026/11/06
JO  - Lasers in Medical Science
DO  - 10.1007/s10103-026-05092-z
UR  - https://doi.org/10.1007/s10103-026-05092-z
AB  - Postoperative hypoparathyroidism remains a prevalent complication of thyroid surgery, primarily caused by unrecognized parathyroid gland (PG) injury or devascularization. While near-infrared autofluorescence (NIRAF) enables accurate PG localization, it provides no functional perfusion information; conversely, laser speckle contrast imaging (LSCI) offers label-free real-time perfusion assessment. Herein, we validated a multimodal endoscopic system integrating NIRAF and LSCI for simultaneous PG identification and vascular evaluation, focusing on LSCI perfusion performance and the clinical practicability of its pseudo-color semi-quantitative visualization. The system was tested in 8 Sprague–Dawley rats, where rat thyroids with homologous blood supply served as perfusion surrogates due to the minute volume of rat PGs. Imaging was performed under three strictly controlled in situ conditions: intact native vascularization, partial vascular occlusion, and complete vascular occlusion. LSCI pseudo-color visualization was generated via a standardized pipeline including temporal laser speckle contrast analysis (tLASCA)-based blood flow index (BFI) calculation, baseline-anchored joint 5th–95th percentile normalization, and Jet colormap mapping. Intraoperative probe-based quantitative NIRAF was used to validate NIRAF-visual signal foci. NIRAF clearly identified PGs with a fluorescence intensity of 149.8 ± 8.7 mV, significantly higher than thyroid (93.8 ± 8.0 mV), trachea (84.6 ± 9.1 mV), and muscle (66.3 ± 10.4 mV) (all P < 0.001), achieving 100% positive predictive value (PPV) and 100% negative predictive value (NPV), with zero false-positive findings among all NIRAF-visual foci. PPV was determined using both probe-based NIRAF and histopathology as dual validation references, whereas NPV was determined using postoperative histopathology alone as the reference standard. LSCI speckle contrast increased progressively with decreasing perfusion, with speckle contrast values mapped to a continuous blue-to-red real-time pseudo-color perfusion visualization. Histopathology confirmed all fluorescent tissues as PGs. This multimodal system targets two core clinical needs for intraoperative PG protection, and its standardized pseudo-color semi-quantitative workflow provides real-time label-free perfusion visualization. It shows potential to serve as an intraoperative adjunct to guide parathyroid preservation decisions and reduce reliance on delayed hormonal test results.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10103-026-05092-z.
SN  - 0268-8921
SN  - 1435-604X
ER  -