Analysis of volatile organic compounds by thermal desorption chromatography mass spectrometry (TD-GC-MS): Breakthrough phenomenon, a parameter to take into account
Abstract
Plants emit diverse volatile organic compounds (VOCs) that are involved in defense, communication, and pollinator attraction. As part of a broader study on VOCs emitted by lavandin fields, VOCs were sampled using a dynamic method involving sorbent tubes containing Tenax TA, followed by thermal desorption and gas chromatography-mass spectrometry analysis. Different parameters were optimized to ensure efficient results. Breakthrough, which causes a loss of molecules in the sampling tubes, was investigated for some molecules of interest, with the aim of quantifying and limiting it. Breakthrough was observed in the field and reached 65% for some compounds, and results showed it was reduced by cooling the tubes during sampling. A new, transportable device was developed to control the temperature around the tubes. The device was validated in laboratory conditions using lavandin essential oil. To complete this study, the cooling device was validated in the field in hot summer conditions reducing breakthrough to below 5% for all target compounds, an acceptable level for reliable quantification.
Related
- Vibrational Excitation of Water Drives Proton Reactivity with Native Proteins During Mid-Infrared Laser Desorption Coupled to Mass Spectrometry.
- Single-Cell Mass Spectrometry Imaging Using Desorption Electrospray Ionization Coupled To Orbitrap Mass Spectrometers
- Microstructure characterization of self-healing vitrimers via matrix assisted laser desorption/ionization (MALDI) and thermal desorption/pyrolysis direct analysis in real time (TDPy-DART) mass spectrometry (MS) techniques
- Ultra-High-Performance Liquid Chromatography-High Resolution Mass Spectrometry and Gas Chromatography-Mass Spectrometry Screening of Classical Psychoactive Substances, Novel Psychoactive Substances, and Metabolites in Postmortem Urine Samples
- Efficient dual-mode liquid chromatography–tandem mass spectrometry methods for quantifying major cyanotoxins in natural water
BibTeX
@article{noel2026analysis,
title = {{Analysis of volatile organic compounds by thermal desorption chromatography mass spectrometry (TD-GC-MS): Breakthrough phenomenon, a parameter to take into account}},
author = {Albane Noël and Charlotte Bringer-Guérin and Patrice Roche and Xavier Fernandez},
journal = {Journal of Chromatography A},
year = {2026},
month = sep,
doi = {10.1016/j.chroma.2026.467362},
url = {https://hal.science/hal-05738794v1},
note = {CC BY},
}
RIS
TY - JOUR
TI - Analysis of volatile organic compounds by thermal desorption chromatography mass spectrometry (TD-GC-MS): Breakthrough phenomenon, a parameter to take into account
AU - Albane Noël
AU - Charlotte Bringer-Guérin
AU - Patrice Roche
AU - Xavier Fernandez
PY - 2026
DA - 2026/09/04
JO - Journal of Chromatography A
DO - 10.1016/j.chroma.2026.467362
UR - https://hal.science/hal-05738794v1
AB - Plants emit diverse volatile organic compounds (VOCs) that are involved in defense, communication, and pollinator attraction. As part of a broader study on VOCs emitted by lavandin fields, VOCs were sampled using a dynamic method involving sorbent tubes containing Tenax TA, followed by thermal desorption and gas chromatography-mass spectrometry analysis. Different parameters were optimized to ensure efficient results. Breakthrough, which causes a loss of molecules in the sampling tubes, was investigated for some molecules of interest, with the aim of quantifying and limiting it. Breakthrough was observed in the field and reached 65% for some compounds, and results showed it was reduced by cooling the tubes during sampling. A new, transportable device was developed to control the temperature around the tubes. The device was validated in laboratory conditions using lavandin essential oil. To complete this study, the cooling device was validated in the field in hot summer conditions reducing breakthrough to below 5% for all target compounds, an acceptable level for reliable quantification.
SN - 0021-9673
SN - 1873-3778
ER -