[Clinical Efficacy of A Novel CT-based Localization Method for Totally Implantable Venous Access Port Placement in Lung Cancer via Internal Jugular Vein].
4 affiliations
- 1Department of Lung Cancer Surgery, Tianjin Medical University General Hospital, Tianjin 300052, China.
- 2Tianjin Key Laboratory of Lung Cancer Metastasis and Tumor Microenvironment, Tianjin Lung Cancer Institute, Tianjin Medical University General Hospital, Tianjin 300052, China.
- 3Tianjin Medical University, Tianjin 300070, China.
- 4Department of Anesthesiology, Tianjin Eye Hospital, Tianjin 300022, China.
Abstract
Background
Implantable venous ports can substantially reduce venous access-related complications in patients undergoing chemotherapy for lung cancer. However, accurate positioning of the catheter tip at the cavoatrial junction (CAJ), defined as the anatomical junction between the superior vena cava (SVC) and right atrium, remains technically challenging. Although electrocardiography (ECG)-guided positioning is widely used in clinical practice, the technique can be relatively complex and time-consuming. Based on clinical practice, we developed a novel computed tomography (CT)-based positioning technique and aimed to evaluate its clinical efficacy and positioning accuracy.Methods
We retrospectively analyzed 40 patients with lung cancer who underwent implantable port placement via the internal jugular vein at the Department of Lung Cancer Surgery, Tianjin Medical University General Hospital, between January 2024 and April 2026. The patients were divided into two groups according to the catheter tip positioning technique: the CT-guided positioning group (n=20) and the ECG-guided positioning group (n=20). Postoperative CT imaging was performed to measure the distance between the catheter tip and the CAJ. The accuracy and variability of catheter tip positioning were compared between the two groups. In addition, the surface anatomical landmarks corresponding to the internal jugular vein puncture site and the CAJ were recorded and analyzed.Results
Compared with the ECG-guided group, the CT-guided group demonstrated significantly greater catheter tip positioning accuracy and lower positional variability (P=0.009). The seventh cervical spinous process (C7) was the most common surface anatomical landmark corresponding to the internal jugular vein puncture site. The surface projection of the CAJ was predominantly located at the level of the 4th costal cartilage and the 4th intercostal space on the anterior chest wall and the 7th-8th costal cartilage level on the posterior thoracic wall.Conclusions
The novel CT-based positioning technique demonstrated greater accuracy and consistency in catheter tip placement than ECG-guided positioning in patients undergoing internal jugular vein port implantation.
Related
- Analgesic Effectiveness of Ultrasound-Guided PECS II Block in Implantable Venous Port Catheter Placement: A Retrospective Comparative Study
- Intraoperative Application of the PRAETORIAN Score to Predict Optimal Subcutaneous Implantable Cardioverter‐Defibrillator Placement
- Comparative safety outcomes of three venous access routes for totally implantable venous access port placement and exploratory assessment of pre-removal catheter-related thrombosis in breast cancer patients
- Fluoroscopic Catheter-Tip Positioning During Internal Jugular TIVAD Placement in Breast Cancer: A Two-Center Retrospective Cohort Study
- Machine-learning prediction of high implantable collamer lens vault using angle-to-angle anatomy: a patient-grouped internal validation study
BibTeX
@article{ren2026clinical,
title = {{[Clinical Efficacy of A Novel CT-based Localization Method for Totally Implantable Venous Access Port Placement in Lung Cancer via Internal Jugular Vein].}},
author = {Dian Ren and Wenhao Zhao and Dinghuan Zhao and Tong Li and Yu Hua and Jing Wang and Jiachen Hu and Yajun Wang and Song Du and Lingyu Guo and Yajie Cui and Mei Li and Huihui Ji and Yi Shi and Xin Li and Jun Chen},
journal = {Zhongguo fei ai za zhi = Chinese journal of lung cancer},
year = {2026},
month = aug,
doi = {10.3779/j.issn.1009-3419.2026.102.23},
url = {https://europepmc.org/article/MED/42896971},
note = {CC BY},
}
RIS
TY - JOUR
TI - [Clinical Efficacy of A Novel CT-based Localization Method for Totally Implantable Venous Access Port Placement in Lung Cancer via Internal Jugular Vein].
AU - Dian Ren
AU - Wenhao Zhao
AU - Dinghuan Zhao
AU - Tong Li
AU - Yu Hua
AU - Jing Wang
AU - Jiachen Hu
AU - Yajun Wang
AU - Song Du
AU - Lingyu Guo
AU - Yajie Cui
AU - Mei Li
AU - Huihui Ji
AU - Yi Shi
AU - Xin Li
AU - Jun Chen
PY - 2026
DA - 2026/08/01
JO - Zhongguo fei ai za zhi = Chinese journal of lung cancer
DO - 10.3779/j.issn.1009-3419.2026.102.23
UR - https://europepmc.org/article/MED/42896971
AB - Background Implantable venous ports can substantially reduce venous access-related complications in patients undergoing chemotherapy for lung cancer. However, accurate positioning of the catheter tip at the cavoatrial junction (CAJ), defined as the anatomical junction between the superior vena cava (SVC) and right atrium, remains technically challenging. Although electrocardiography (ECG)-guided positioning is widely used in clinical practice, the technique can be relatively complex and time-consuming. Based on clinical practice, we developed a novel computed tomography (CT)-based positioning technique and aimed to evaluate its clinical efficacy and positioning accuracy.Methods We retrospectively analyzed 40 patients with lung cancer who underwent implantable port placement via the internal jugular vein at the Department of Lung Cancer Surgery, Tianjin Medical University General Hospital, between January 2024 and April 2026. The patients were divided into two groups according to the catheter tip positioning technique: the CT-guided positioning group (n=20) and the ECG-guided positioning group (n=20). Postoperative CT imaging was performed to measure the distance between the catheter tip and the CAJ. The accuracy and variability of catheter tip positioning were compared between the two groups. In addition, the surface anatomical landmarks corresponding to the internal jugular vein puncture site and the CAJ were recorded and analyzed.Results Compared with the ECG-guided group, the CT-guided group demonstrated significantly greater catheter tip positioning accuracy and lower positional variability (P=0.009). The seventh cervical spinous process (C7) was the most common surface anatomical landmark corresponding to the internal jugular vein puncture site. The surface projection of the CAJ was predominantly located at the level of the 4th costal cartilage and the 4th intercostal space on the anterior chest wall and the 7th-8th costal cartilage level on the posterior thoracic wall.Conclusions The novel CT-based positioning technique demonstrated greater accuracy and consistency in catheter tip placement than ECG-guided positioning in patients undergoing internal jugular vein port implantation.
SN - 1009-3419
SN - 1999-6187
ER -