Skip to content
DraconiticResearch
Search Sources API
201,642 studies31 sourcesUpdated 15 min ago
Peer-reviewedCC BY 4.0Bioinformatics

SomatiX: accurate and efficient somatic SNV detection from matched tumor-normal long-read DNA sequencing

  1. 1Independent Researcher, Philadelphia, United States

Abstract

Motivation: Accurate somatic single-nucleotide variant (SNV) calling from matched tumor-normal long-read DNA sequencing remains challenging because sequencing errors, variable tumor purity, tumor-in-normal contamination, and low variant allele fractions (VAFs) can obscure tumor-specific signals. Although recent deep-learning methods have improved long-read somatic variant calling, robust low-VAF detection and efficient genome-scale analysis remain important methodological challenges.

Results: We present SomatiX, a deep-learning method for somatic SNV detection from matched tumor-normal long-read DNA sequencing data, built on an allele-aware pileup representation. In comprehensive cancer benchmark analyses across diverse cell-line datasets, sequencing contexts, VAF bins, and minimum variant-supporting read thresholds, SomatiX outperformed DeepSomatic and ClairS in F1 score across most Oxford Nanopore Technologies (ONT) benchmark conditions and achieved competitive performance on Pacific Biosciences (PacBio) data. Across the held-out chromosome 1 cancer cell-line benchmarks, at the threshold of ≥3 variant-supporting reads and a VAF ≥0.05, SomatiX achieved mean F1 scores of 0.986 for ONT data and 0.988 for PacBio data. SomatiX showed particularly strong performance for low-VAF SNVs in ONT data while using a compact model and achieving the fastest runtime among the evaluated tools.

Availability and implementation: SomatiX is available at https://github.com/colinliuzelin/SomatiX and archived at Zenodo under DOI: https://doi.org/10.5281/zenodo.22062438. The repository includes source code, trained models, and benchmarking scripts.

Related

  1. Accurate calling of low-frequency somatic mutations by sample-specific modeling of error rates
    Yixin Lin, Carmen Lääs, Peter Sørud Porsborg +7
    BMC BiologyPeer-reviewedCC BY-NC-ND 4.0Molecular biology & gene regulationCrossref
  2. Accurate prediction of CRISPR editing outcomes in somatic cell lines and zygotes with few-shot learning with inDecay.
    Weizhong Zheng, Lu Yu, Chao Wu +14
    Genome biologyPeer-reviewedCC BY-NC-NDFull textMolecular biology & gene regulationEurope PMCDOAJ
  3. Somatic mutations in neurodegeneration: from detection to disease mechanisms
    Anna Piaszyk-Borychowska, Weronika Śliwińska, Marta Olejniczak
    BMC BiologyPeer-reviewedCC BY 4.0Molecular biology & gene regulationGeneral biologyCrossref
  4. Accurate and efficient prediction of protein conformations with ProtMonomer
    Y. Si, S. Zhang, L. Chen
    bioRxivPreprintCC BY-NDFull textMolecular biology & gene regulationbioRxiv
  5. IndelQuant: A Workflow for Cost-Efficient Amplicon Sequencing Analysis of Genome-Edited Chickens
    Yujuan Duan, Ke Xu, Hao Zhou +6
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationCrossrefEurope PMC
BibTeX
@article{liu2026somatix,
  title = {{SomatiX: accurate and efficient somatic SNV detection from matched tumor-normal long-read DNA sequencing}},
  author = {Zelin Liu},
  journal = {Bioinformatics},
  year = {2026},
  month = oct,
  doi = {10.1093/bioinformatics/btag792},
  url = {https://doi.org/10.1093/bioinformatics/btag792},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - SomatiX: accurate and efficient somatic SNV detection from matched tumor-normal long-read DNA sequencing
AU  - Zelin Liu
PY  - 2026
DA  - 2026/10/24
JO  - Bioinformatics
DO  - 10.1093/bioinformatics/btag792
UR  - https://doi.org/10.1093/bioinformatics/btag792
AB  - Motivation: Accurate somatic single-nucleotide variant (SNV) calling from matched tumor-normal long-read DNA sequencing remains challenging because sequencing errors, variable tumor purity, tumor-in-normal contamination, and low variant allele fractions (VAFs) can obscure tumor-specific signals. Although recent deep-learning methods have improved long-read somatic variant calling, robust low-VAF detection and efficient genome-scale analysis remain important methodological challenges.  Results: We present SomatiX, a deep-learning method for somatic SNV detection from matched tumor-normal long-read DNA sequencing data, built on an allele-aware pileup representation. In comprehensive cancer benchmark analyses across diverse cell-line datasets, sequencing contexts, VAF bins, and minimum variant-supporting read thresholds, SomatiX outperformed DeepSomatic and ClairS in F1 score across most Oxford Nanopore Technologies (ONT) benchmark conditions and achieved competitive performance on Pacific Biosciences (PacBio) data. Across the held-out chromosome 1 cancer cell-line benchmarks, at the threshold of ≥3 variant-supporting reads and a VAF ≥0.05, SomatiX achieved mean F1 scores of 0.986 for ONT data and 0.988 for PacBio data. SomatiX showed particularly strong performance for low-VAF SNVs in ONT data while using a compact model and achieving the fastest runtime among the evaluated tools.  Availability and implementation: SomatiX is available at https://github.com/colinliuzelin/SomatiX and archived at Zenodo under DOI: https://doi.org/10.5281/zenodo.22062438. The repository includes source code, trained models, and benchmarking scripts.
SN  - 1367-4803
SN  - 1367-4811
ER  -