Leak localisation with a measure source convection-diffusion model
Abstract
Taking a variational approach, study the inverse problem of locating gas leaks from line-of-sight concentration measurements using a convection--diffusion model with the source term a Radon measure. By imposing sparsity-promoting regularisation on this measure, we recover point sources---identifying both their locations and intensities---rather than diffuse approximations. We jointly estimate the underlying physical convection (wind) and diffusion parameters. Our main theoretical contribution is the analysis of Lipschitz dependence of the forward solution of the convection--diffusion equation with respect to its parameters: the measure, and the convection and diffusion fields. Numerically, we employ a semi-grid-free optimisation approach for reconstructing the source measure. Our experiments demonstrate accurate localisation, highlighting the potential of the method for practical gas emission detection.
Related
- Subdivision-based collocation methods for time fractional convection diffusion reaction equation with environmental and biomedical applications
- 1D Convection-Diffusion in Porous Media: A Unified Solution from Bounded Domain to Half-Space
- On the optimal decay rate of global solutions to the convection-diffusion equation with zero-mass initial data
- A stabilized scheme satisfying the discrete maximum principle for a time fractional convection-diffusion-reaction equation
- Large self-similar solutions of a convection--diffusion equation
BibTeX
@misc{dang2026leak,
title = {{Leak localisation with a measure source convection-diffusion model}},
author = {Thi Tam Dang and Tuomo Valkonen},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2605.12095},
eprint = {2605.12095},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2605.12095},
}
RIS
TY - UNPB
TI - Leak localisation with a measure source convection-diffusion model
AU - Thi Tam Dang
AU - Tuomo Valkonen
PY - 2026
DA - 2026/10/09
PB - arXiv
DO - 10.48550/arxiv.2605.12095
UR - https://arxiv.org/abs/2605.12095
AB - Taking a variational approach, study the inverse problem of locating gas leaks from line-of-sight concentration measurements using a convection--diffusion model with the source term a Radon measure. By imposing sparsity-promoting regularisation on this measure, we recover point sources---identifying both their locations and intensities---rather than diffuse approximations. We jointly estimate the underlying physical convection (wind) and diffusion parameters. Our main theoretical contribution is the analysis of Lipschitz dependence of the forward solution of the convection--diffusion equation with respect to its parameters: the measure, and the convection and diffusion fields. Numerically, we employ a semi-grid-free optimisation approach for reconstructing the source measure. Our experiments demonstrate accurate localisation, highlighting the potential of the method for practical gas emission detection.