Comparative evaluation of two automated magnetic-bead cfDNA extraction workflows in early colorectal cancer

Abstract

Reliable plasma cell-free DNA extraction is a key component of liquid biopsy testing and requires standardized preanalytical workflows. We conducted a paired comparison of 2 automated extraction methods, the Maxwell RSC ccfDNA LV Plasma Kit and the Maxwell RSC Rapid ccfDNA Kit, using EDTA plasma samples from 48 patients with early-stage colorectal cancer. For each patient, 4 mL of plasma was divided into two 2 mL aliquots and processed on the same instrument according to the manufacturer’s instructions. Cell-free DNA was measured by fluorometry and capillary electrophoresis, and outcomes were analyzed using linear mixed-effects models with extraction kit as a fixed effect and patient as a random intercept. Measurements obtained by the two analytical platforms were strongly correlated. Compared with the Standard workflow, the Rapid workflow showed significantly higher values across all evaluated concentration and fragment-distribution endpoints, including total DNA concentration and fragment recovery in the 50–700 bp and 100–300 bp ranges. In this early-stage colorectal cancer cohort, the Rapid workflow showed higher cfDNA recovery and a greater representation of fragments within the evaluated cfDNA size ranges than the Standard workflow. These findings are limited to upstream extraction and quality-control metrics and do not establish improved mutation detection, analytical sensitivity, or suitability for downstream molecular assays. The findings indicate that this simplified workflow may be a practical alternative for routine plasma cell-free DNA extraction, although local analytical verification remains advisable.

Related

  1. Comparative outcomes of natural orifice specimen extraction surgery versus conventional minilaparotomy-assisted specimen extraction in colorectal cancer: A single-center retrospective study.
    Yongjian Liao, Runfeng Qiu, Wenli Ma
    MedicinePeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Application of a Quantitative POCT-FIT Based on Near-Infrared Fluorescence Immunochromatography in Population-Based Colorectal Cancer Screening: A Comparative Evaluation with a Centralized Testing System
    Fang-Chao Zhu, Yu-Lin Ku, Jie Pan +2
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Comparative Evaluation of Microwave- and Ultrasound-Assisted Extraction of Antioxidants from Parsley (Petroselinum crispum (Mill.) Fuss) and Coriander (Coriandrum sativum L.) Processing By-Products.
    Joana Solinho, Élia Fernandes, Diana Barros +2
    Foods (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Comparative evaluation of large language models for guideline-concordant decision support in colorectal cancer multidisciplinary team care: A source-masked retrospective study
    Zheng Zhang, Qi Zhao, Shuang Han +11
    Intelligent OncologyPeer-reviewedCC BYFull textEpidemiology & public healthDOAJ
  5. Environmental impact of urine analyses: Comparison of manual, semi and fully automated analytical workflows
    Julien Brunier, Clara Mourgues, Fanny Auger +4
    The Journal of Climate Change and HealthPeer-reviewedCC BY 4.0Full textGeneral biologyEpidemiology & public healthHAL
BibTeX
@article{denninghoff2026comparative,
  title = {{Comparative evaluation of two automated magnetic-bead cfDNA extraction workflows in early colorectal cancer}},
  author = {Valeria Denninghoff and Inés Aznar-Peralta and Cristóbal Fresno and Álvaro Mellado-Cuesta and Simona Innamorato and María Pilar Molina-Vallejos and Javier López-Hidalgo and María José Serrano},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-69239-2},
  url = {https://www.nature.com/articles/s41598-026-69239-2},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Comparative evaluation of two automated magnetic-bead cfDNA extraction workflows in early colorectal cancer
AU  - Valeria Denninghoff
AU  - Inés Aznar-Peralta
AU  - Cristóbal Fresno
AU  - Álvaro Mellado-Cuesta
AU  - Simona Innamorato
AU  - María Pilar Molina-Vallejos
AU  - Javier López-Hidalgo
AU  - María José Serrano
PY  - 2026
DA  - 2026/10/27
JO  - Scientific Reports
DO  - 10.1038/s41598-026-69239-2
UR  - https://www.nature.com/articles/s41598-026-69239-2
AB  - Reliable plasma cell-free DNA extraction is a key component of liquid biopsy testing and requires standardized preanalytical workflows. We conducted a paired comparison of 2 automated extraction methods, the Maxwell RSC ccfDNA LV Plasma Kit and the Maxwell RSC Rapid ccfDNA Kit, using EDTA plasma samples from 48 patients with early-stage colorectal cancer. For each patient, 4 mL of plasma was divided into two 2 mL aliquots and processed on the same instrument according to the manufacturer’s instructions. Cell-free DNA was measured by fluorometry and capillary electrophoresis, and outcomes were analyzed using linear mixed-effects models with extraction kit as a fixed effect and patient as a random intercept. Measurements obtained by the two analytical platforms were strongly correlated. Compared with the Standard workflow, the Rapid workflow showed significantly higher values across all evaluated concentration and fragment-distribution endpoints, including total DNA concentration and fragment recovery in the 50–700 bp and 100–300 bp ranges. In this early-stage colorectal cancer cohort, the Rapid workflow showed higher cfDNA recovery and a greater representation of fragments within the evaluated cfDNA size ranges than the Standard workflow. These findings are limited to upstream extraction and quality-control metrics and do not establish improved mutation detection, analytical sensitivity, or suitability for downstream molecular assays. The findings indicate that this simplified workflow may be a practical alternative for routine plasma cell-free DNA extraction, although local analytical verification remains advisable.
SN  - 2045-2322
ER  -