3D M-FFE Sequence for Assessment of Osseous Abnormalities in the Knee.
7 affiliations
- 1Department of Radiology, University Hospital of Southern Denmark, DK-5000 Middelfart, Denmark.
- 2Department of Radiology, University Hospital of Southern Denmark, DK-7100 Vejle, Denmark.
- 3Research Support Unit, Lillebælt Hospital, University Hospitals of Southern Denmark, Beriderbakken 4, DK-7100 Vejle, Denmark.
- 4Institute for Regional Health Research, University of Southern Denmark, Campusvej 55, DK-5230 Odense, Denmark.
- 5Department of Regional Health Research, University of Southern Denmark, Campusvej 55, DK-5230 Odense, Denmark.
- 6Discipline of Medical Imaging and Radiation Therapy, School of Medicine, University College Cork, T12 AK54 Cork, Ireland.
- 7Radiography Education, VIA University College, Overgade 6, DK-7400 Herning, Denmark.
Abstract
Background/objectives
To evaluate the potential complementary value of the 3D multi fast field echo (M-FFE) sequence for knee bone assessment at 1.5T MRI, focusing on the visualization of osseous abnormalities and its potential to complement a standard knee MRI protocol.Methods
A standard knee MRI protocol supplemented with a 3D M-FFE sequence was performed at 1.5T MRI in 49 outpatients. Two observers independently evaluated image quality, visualization of six anatomical knee structures, and osseous abnormalities using a 5-point Likert scale. Intra- and interrater reliability was assessed using intraclass correlation coefficients and Cohen's kappa. Eleven examinations were reassessed for intra-rater reliability. Diagnostic confidence with the 3D M-FFE sequence was evaluated.Results
Image quality was consistently high, with sharpness and artifact scores of 4-5 in >95% of examinations, while contrast showed greater variability, and no examinations scored below 3. Osseous abnormalities were identified in 18/49 patients by each observer, with agreement in 12 cases. A total of 28 and 25 abnormalities were identified by the observers, most commonly osteochondral lesions and bone islands. Abnormalities were assigned visualization scores of 4-5. Inter-rater agreement for osseous abnormalities ranged from fair to substantial (kappa = 0.40-0.76), while intra-rater agreement varied from slight to almost perfect depending on anatomical location. Both observers reported increased perceived diagnostic confidence in osseous abnormalities with the addition of the 3D M-FFE sequence.Conclusions
The 3D M-FFE sequence demonstrated high image quality, robust anatomical visualization, and potential complementary value for osseous assessment at 1.5T MRI. Further studies using an appropriate reference standard are needed to establish diagnostic accuracy.
Related
- Quantitative Whole-Leg Radiographic Assessment of Coronal Knee–Ankle Alignment: Associations with Talar Inclination and Exploratory Changes After Knee Osteotomy
- Spectral CT material decomposition for non-invasive quantitative assessment of metabolic and elemental abnormalities in liver cirrhosis: a narrative review
- Acupuncture and related needling in sports-related knee rehabilitation: a narrative review of neurophysiological mechanisms and assessment methods
- Volumetric Analysis of the Deltoid Muscle From Neck-to-Knee Dixon MRI: A pilot population assessment of a posterior intramuscular injection target
- Feasibility and perceptions among hemophilia patients and doctors towards ultrasound for the assessment of subclinical abnormalities in hemophilic joints.
BibTeX
@article{rasmussen2026mffe,
title = {{3D M-FFE Sequence for Assessment of Osseous Abnormalities in the Knee.}},
author = {Julie Aase Rasmussen and Christian Ørnfelt Lund and Eka Raj Aryal and Flemming Skjøth and Malene Roland Vils Pedersen},
journal = {Tomography (Ann Arbor, Mich.)},
year = {2026},
month = oct,
doi = {10.3390/tomography12110153},
url = {https://europepmc.org/article/MED/43083643},
note = {CC BY},
}
RIS
TY - JOUR
TI - 3D M-FFE Sequence for Assessment of Osseous Abnormalities in the Knee.
AU - Julie Aase Rasmussen
AU - Christian Ørnfelt Lund
AU - Eka Raj Aryal
AU - Flemming Skjøth
AU - Malene Roland Vils Pedersen
PY - 2026
DA - 2026/10/22
JO - Tomography (Ann Arbor, Mich.)
DO - 10.3390/tomography12110153
UR - https://europepmc.org/article/MED/43083643
AB - Background/objectives To evaluate the potential complementary value of the 3D multi fast field echo (M-FFE) sequence for knee bone assessment at 1.5T MRI, focusing on the visualization of osseous abnormalities and its potential to complement a standard knee MRI protocol.Methods A standard knee MRI protocol supplemented with a 3D M-FFE sequence was performed at 1.5T MRI in 49 outpatients. Two observers independently evaluated image quality, visualization of six anatomical knee structures, and osseous abnormalities using a 5-point Likert scale. Intra- and interrater reliability was assessed using intraclass correlation coefficients and Cohen's kappa. Eleven examinations were reassessed for intra-rater reliability. Diagnostic confidence with the 3D M-FFE sequence was evaluated.Results Image quality was consistently high, with sharpness and artifact scores of 4-5 in >95% of examinations, while contrast showed greater variability, and no examinations scored below 3. Osseous abnormalities were identified in 18/49 patients by each observer, with agreement in 12 cases. A total of 28 and 25 abnormalities were identified by the observers, most commonly osteochondral lesions and bone islands. Abnormalities were assigned visualization scores of 4-5. Inter-rater agreement for osseous abnormalities ranged from fair to substantial (kappa = 0.40-0.76), while intra-rater agreement varied from slight to almost perfect depending on anatomical location. Both observers reported increased perceived diagnostic confidence in osseous abnormalities with the addition of the 3D M-FFE sequence.Conclusions The 3D M-FFE sequence demonstrated high image quality, robust anatomical visualization, and potential complementary value for osseous assessment at 1.5T MRI. Further studies using an appropriate reference standard are needed to establish diagnostic accuracy.
SN - 2379-1381
SN - 2379-139X
ER -