An integrated geometric quantification and shape analysis framework for axillary lymph node metastasis in breast cancer patients
Abstract
Quantitative characterization of lymph node morphology is important for assessing axillary lymph node metastasis in breast cancer. However, surfaces reconstructed from computed tomography (CT) segmentation may contain geometric and topological defects that compromise subsequent analysis, while conventional shape descriptors predominantly characterize global morphology. To address these issues, we developed an integrated framework combining topology-aware surface processing with multi-resolution spherical harmonic (SH) analysis of CT-derived axillary lymph nodes. The processing pipeline produced topology-valid genus-0 surfaces with improved mesh quality, which were then represented at multiple SH degrees and characterized using 20 predefined geometric feature families. Geometric fidelity increased with SH degree, whereas predictive performance peaked at intermediate resolutions. Preferred SH degree also differed across feature families. A family-specific mixed-resolution model achieved an AUC of 0.918, compared with 0.884 for the conventional PyRadiomics Shape14 baseline, corresponding to an improvement of 0.0344. Controlled perturbation experiments showed that higher SH degrees transmitted more fine-scale geometric variation and yielded lower stability of curvature-based predictions. Representative geometric descriptors provided interpretable characterization of metastasis-associated surface morphology. Independent validation further supported the framework's transportability: label-free replication in a multicenter lymph node cohort reproduced the family-specific resolution effects, while a labeled LIDC-IDRI lung-nodule experiment reproduced the resolution-dependent relationship between SH degree and predictive performance. Altogether, the framework provides a topology-valid basis for quantitative characterization of lymph node morphology and metastasis-associated imaging phenotypes.
Related
- Cross-cancer knowledge transfer for lymph node metastasis prediction: Applicability of an axillary lymph node-based deep learning model
- An Integrated Cell Culture - Nanopore Sequencing (ICC-NanoporeSeq) method for the simultaneous detection of multiple enterovirus types and quantification of infectious Enterovirus B
- MRSIPrep: A Standardized Post-Quantification Framework for Preprocessing Whole-Brain Magnetic Resonance Spectroscopic Imaging
- A Framework for SPICE MRSI Reconstruction Posterior Uncertainty Quantification
- GaussF: An Unbiased Gaussian Framework for High-Precision Transcript Quantification with a Programmable Self-Benchmark Model
BibTeX
@misc{yi2026integrated,
title = {{An integrated geometric quantification and shape analysis framework for axillary lymph node metastasis in breast cancer patients}},
author = {Zixi Yi and Limeng Qu and Gary P. T. Choi},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2609.35437},
eprint = {2609.35437},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2609.35437},
}
RIS
TY - UNPB
TI - An integrated geometric quantification and shape analysis framework for axillary lymph node metastasis in breast cancer patients
AU - Zixi Yi
AU - Limeng Qu
AU - Gary P. T. Choi
PY - 2026
DA - 2026/09/28
PB - arXiv
DO - 10.48550/arxiv.2609.35437
UR - https://arxiv.org/abs/2609.35437
AB - Quantitative characterization of lymph node morphology is important for assessing axillary lymph node metastasis in breast cancer. However, surfaces reconstructed from computed tomography (CT) segmentation may contain geometric and topological defects that compromise subsequent analysis, while conventional shape descriptors predominantly characterize global morphology. To address these issues, we developed an integrated framework combining topology-aware surface processing with multi-resolution spherical harmonic (SH) analysis of CT-derived axillary lymph nodes. The processing pipeline produced topology-valid genus-0 surfaces with improved mesh quality, which were then represented at multiple SH degrees and characterized using 20 predefined geometric feature families. Geometric fidelity increased with SH degree, whereas predictive performance peaked at intermediate resolutions. Preferred SH degree also differed across feature families. A family-specific mixed-resolution model achieved an AUC of 0.918, compared with 0.884 for the conventional PyRadiomics Shape14 baseline, corresponding to an improvement of 0.0344. Controlled perturbation experiments showed that higher SH degrees transmitted more fine-scale geometric variation and yielded lower stability of curvature-based predictions. Representative geometric descriptors provided interpretable characterization of metastasis-associated surface morphology. Independent validation further supported the framework's transportability: label-free replication in a multicenter lymph node cohort reproduced the family-specific resolution effects, while a labeled LIDC-IDRI lung-nodule experiment reproduced the resolution-dependent relationship between SH degree and predictive performance. Altogether, the framework provides a topology-valid basis for quantitative characterization of lymph node morphology and metastasis-associated imaging phenotypes.
ER -