Development of a Standardized ELISA for Detecting IgG4 Autoantibodies Against Contactin 1
13 affiliations
- 1Department of Neurology, Neurological Institute, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
- 2Research and Development Section, Diagnostics Division, Yamasa Corporation, Chiba, Japan.
- 3Center for Clinical and Translational Research, Kyushu University Hospital, Fukuoka, Japan.
- 4Department of Neurology, Kindai University Faculty of Medicine, Osaka, Japan.
- 5Department of Neurology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
- 6Department of Advanced Medicine, Nagoya University Hospital, Nagoya, Japan.
- 7Department of Neurology, Graduate School of Medicine, Chiba University, Chiba, Japan.
- 8Department of Neurology and Geriatric Medicine, Graduate School of Medicine, Ehime University, Matsuyama, Japan.
- 9Department of Neurology, Saitama Medical Center, Saitama Medical University, Saitama, Japan.
- 10Department of Neurology, Saga University, Saga, Japan.
- 11School of Health Sciences, Yamaguchi University Graduate School of Medicine, Yamaguchi, Japan.
- 12Neuromuscular Center Yoshimizu Hospital, Yamaguchi, Japan.
- 13Translational Neuroscience Research Center, Graduate School of Medicine, International University of Health and Welfare, Fukuoka, Japan.
Abstract
Background and aims
IgG4 autoantibodies against contactin-1 (CNTN1) are diagnostic markers for autoimmune nodopathies (ANs) distinct from chronic inflammatory demyelinating polyradiculoneuropathy (CIDP). However, a standardized quantitative enzyme-linked immunosorbent assay (ELISA) for CNTN1-IgG4 detection has not been available. This study aimed to validate the performance of a newly developed ELISA kit.Methods
The extracellular domain of human CNTN1 expressed in mammalian cells served as the antigen, with purified IgG from CNTN1-IgG4-positive patients as a reference. For clinical validation, 135 samples were obtained from 101 CIDP patients, including serial sera from four CNTN1-IgG4-positive cases, along with 111 samples from other demyelinating polyneuropathy patients and 40 healthy volunteers. CNTN1-IgG4 was measured by ELISA and a cell-based assay (CBA) with flow cytometry under blinded conditions, and concordance between the two methods was assessed. Serial samples from four CNTN1-IgG4-positive patients were analyzed to examine correlations between antibody fluctuations and clinical/electrophysiological changes.Results
The ELISA demonstrated acceptable intra- and inter-assay variability and good dilution linearity. Using a cut-off of 5.0 U/mL, the ELISA achieved 97.8% concordance with CBA for CIDP samples and 98.3% across all samples, with a strong correlation between methods. CNTN1-IgG4-positive cases showed elderly onset age and high cerebrospinal fluid protein levels. In four CNTN1-IgG4-positive patients, reductions in antibody levels preceded subsequent clinical and electrophysiological improvements.Interpretation
This novel ELISA provides a standardized and quantitative method for diagnosing CNTN1-IgG4-positive AN. It offers accuracy comparable to CBA with greater simplicity and reproducibility, enabling disease monitoring and supporting its clinical utility for diagnosis and longitudinal management.
Related
- Autoantibodies Against Type I Interferons and Death from H7N7 Avian Flu
- Autoantibodies against N-terminal EF-hand calcium-binding protein 1 in neurological syndromes and cancer
- Elevated autoantibodies against dipeptidyl peptidase-4 are associated with poor prognosis in patients with type 2 diabetes
- Detecting low left ventricular ejection fraction from ECG using an interpretable and scalable predictor-driven framework: a model development and validation study
- Efgartigimod-responsive autoimmune peripheral neuropathy with concurrent anti-GM2 IgG and anti-contactin-1 IgG antibodies: a rare case report.
BibTeX
@article{ogata2026development,
title = {{Development of a Standardized ELISA for Detecting IgG4 Autoantibodies Against Contactin 1}},
author = {Hidenori Ogata and Atsushi Kawasaki and Chieri Takeuchi and Yuko Kobayakawa and Motoi Kuwahara and Yuki Fukami and Shinobu Shimizu and Tomoki Suichi and Kazumoto Shibuya and Hitoshi Hayashida and Takumi Tashiro and Ryo Yamasaki and Masahiro Iijima and Masahiro Mori and Kenichi Kaida and Haruki Koike and Michiaki Koga and Takashi Kanda and Yoshitaka Nagai and Masahisa Katsuno and Satoshi Kuwabara and Jun-Ichi Kira and Noriko Isobe},
journal = {Journal of the peripheral nervous system : JPNS},
year = {2026},
month = nov,
doi = {10.1111/jns.70186},
url = {https://europepmc.org/article/PMC/PMC13796010},
note = {CC BY},
}
RIS
TY - JOUR
TI - Development of a Standardized ELISA for Detecting IgG4 Autoantibodies Against Contactin 1
AU - Hidenori Ogata
AU - Atsushi Kawasaki
AU - Chieri Takeuchi
AU - Yuko Kobayakawa
AU - Motoi Kuwahara
AU - Yuki Fukami
AU - Shinobu Shimizu
AU - Tomoki Suichi
AU - Kazumoto Shibuya
AU - Hitoshi Hayashida
AU - Takumi Tashiro
AU - Ryo Yamasaki
AU - Masahiro Iijima
AU - Masahiro Mori
AU - Kenichi Kaida
AU - Haruki Koike
AU - Michiaki Koga
AU - Takashi Kanda
AU - Yoshitaka Nagai
AU - Masahisa Katsuno
AU - Satoshi Kuwabara
AU - Jun-Ichi Kira
AU - Noriko Isobe
PY - 2026
DA - 2026/11/24
JO - Journal of the peripheral nervous system : JPNS
DO - 10.1111/jns.70186
UR - https://europepmc.org/article/PMC/PMC13796010
AB - Background and aims IgG4 autoantibodies against contactin-1 (CNTN1) are diagnostic markers for autoimmune nodopathies (ANs) distinct from chronic inflammatory demyelinating polyradiculoneuropathy (CIDP). However, a standardized quantitative enzyme-linked immunosorbent assay (ELISA) for CNTN1-IgG4 detection has not been available. This study aimed to validate the performance of a newly developed ELISA kit.Methods The extracellular domain of human CNTN1 expressed in mammalian cells served as the antigen, with purified IgG from CNTN1-IgG4-positive patients as a reference. For clinical validation, 135 samples were obtained from 101 CIDP patients, including serial sera from four CNTN1-IgG4-positive cases, along with 111 samples from other demyelinating polyneuropathy patients and 40 healthy volunteers. CNTN1-IgG4 was measured by ELISA and a cell-based assay (CBA) with flow cytometry under blinded conditions, and concordance between the two methods was assessed. Serial samples from four CNTN1-IgG4-positive patients were analyzed to examine correlations between antibody fluctuations and clinical/electrophysiological changes.Results The ELISA demonstrated acceptable intra- and inter-assay variability and good dilution linearity. Using a cut-off of 5.0 U/mL, the ELISA achieved 97.8% concordance with CBA for CIDP samples and 98.3% across all samples, with a strong correlation between methods. CNTN1-IgG4-positive cases showed elderly onset age and high cerebrospinal fluid protein levels. In four CNTN1-IgG4-positive patients, reductions in antibody levels preceded subsequent clinical and electrophysiological improvements.Interpretation This novel ELISA provides a standardized and quantitative method for diagnosing CNTN1-IgG4-positive AN. It offers accuracy comparable to CBA with greater simplicity and reproducibility, enabling disease monitoring and supporting its clinical utility for diagnosis and longitudinal management.
SN - 1085-9489
SN - 1529-8027
ER -