Can a 3D Printed Chondrograft Implant Offer a Solution for Full Thickness Cartilage Lesions in an Equine Preclinical Model?
4 affiliations
- 1Department of Clinical Sciences Orthopaedic Research Center, Translational Medicine Institute, CSU Fort Collins Colorado USA
- 2Department of Mechanical Engineering Orthopaedic Bioengineering Research Laboratory, CSU Fort Collins Colorado USA
- 3Nanochon, Inc Washington District of Columbia USA
- 4Charter Preclinical Services Hudson Massachusetts USA
Abstract
Articular cartilage defects have limited ability to heal resulting in fibrocartilage that is functionally and structurally inferior to hyaline cartilage. The aim of this study was to validate the Chondrograft Implant for full thickness cartilage lesion treatment, assessing its ability to fill the defect and support repair tissue engraftment. Bilateral 15 mm diameter cartilage defects were created on the lateral trochlear ridge of the femur in 12 skeletally mature horses. One defect was treated with the implant while the contralateral limb was an empty control defect. Horses were exercised starting at week 4 and study end points were at 36‐weeks for 4 horses and 52‐weeks for 8 horses. Lameness examinations were performed every 4 weeks and arthroscopic recheck surgeries were performed at 12‐weeks. Post‐mortem evaluation included macroscopic appearance, MRI, histology and biomechanical testing. Clinical, ICRS, MRI and gross morphology outcomes were compared between groups using parametric or non‐parametric tests as appropriate. Mechanical stiffness was compared between groups using two‐way ANOVA with Tukey's post‐hoc. There was no difference in lameness between control or treated limbs (p > 0.5). The 12‐week arthroscopy showed treated defects had significantly improved fill (99% vs 42%, p < 0.0001) and ICRS scores (11.3 ± 1.1 vs 4.1 ± 3.1, p < 0.0001). Endpoint ICRS grade at 52‐ weeks was significantly better in the treated defect compared to the control defect scoring (3.75 ± 2.25 vs 9.125 ± 2.25, p = 0.0005). Biomechanical testing revealed significantly improved repair tissue stiffness in treated defects compared to controls (p < 0.0001). Chondrograft implants resulted in excellent defect filling with biomechanical function similar to normal healthy articular cartilage.
Related
- Arthroscopic Marrow‐Stimulating Procedure for Full‐Thickness Knee Cartilage Lesions
- Utility of ultrasound as a diagnostic tool for measuring knee cartilage thickness in patients with osteoarthritis: correlation with MRI
- Trochlear Shell Osteochondral Allograft Transplantation for Full-Thickness Trochlear Cartilage Lesions.
- Targeting bone and cartilage: A practical guideline for tissue- and cell-specific delivery tools in preclinical studies
- Visualization of Eustachian Tube Cartilage on Delayed Contrast-enhanced MR Imaging
BibTeX
@article{barton2026printed,
title = {{Can a 3D Printed Chondrograft Implant Offer a Solution for Full Thickness Cartilage Lesions in an Equine Preclinical Model?}},
author = {Charlotte K. Barton and Kathryn A. Seabaugh and Benjamin C. Gadomski and Kevin M. Labus and Benjamin B. Holmes and Nathan J. Castro and Michael L. Hawes and Brad B. Nelson and Laurie R. Goodrich},
journal = {Journal of Orthopaedic Research},
year = {2026},
month = nov,
doi = {10.1002/jor.70312},
url = {https://doi.org/10.1002/jor.70312},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Can a 3D Printed Chondrograft Implant Offer a Solution for Full Thickness Cartilage Lesions in an Equine Preclinical Model?
AU - Charlotte K. Barton
AU - Kathryn A. Seabaugh
AU - Benjamin C. Gadomski
AU - Kevin M. Labus
AU - Benjamin B. Holmes
AU - Nathan J. Castro
AU - Michael L. Hawes
AU - Brad B. Nelson
AU - Laurie R. Goodrich
PY - 2026
DA - 2026/11/18
JO - Journal of Orthopaedic Research
DO - 10.1002/jor.70312
UR - https://doi.org/10.1002/jor.70312
AB - Articular cartilage defects have limited ability to heal resulting in fibrocartilage that is functionally and structurally inferior to hyaline cartilage. The aim of this study was to validate the Chondrograft Implant for full thickness cartilage lesion treatment, assessing its ability to fill the defect and support repair tissue engraftment. Bilateral 15 mm diameter cartilage defects were created on the lateral trochlear ridge of the femur in 12 skeletally mature horses. One defect was treated with the implant while the contralateral limb was an empty control defect. Horses were exercised starting at week 4 and study end points were at 36‐weeks for 4 horses and 52‐weeks for 8 horses. Lameness examinations were performed every 4 weeks and arthroscopic recheck surgeries were performed at 12‐weeks. Post‐mortem evaluation included macroscopic appearance, MRI, histology and biomechanical testing. Clinical, ICRS, MRI and gross morphology outcomes were compared between groups using parametric or non‐parametric tests as appropriate. Mechanical stiffness was compared between groups using two‐way ANOVA with Tukey's post‐hoc. There was no difference in lameness between control or treated limbs (p > 0.5). The 12‐week arthroscopy showed treated defects had significantly improved fill (99% vs 42%, p < 0.0001) and ICRS scores (11.3 ± 1.1 vs 4.1 ± 3.1, p < 0.0001). Endpoint ICRS grade at 52‐ weeks was significantly better in the treated defect compared to the control defect scoring (3.75 ± 2.25 vs 9.125 ± 2.25, p = 0.0005). Biomechanical testing revealed significantly improved repair tissue stiffness in treated defects compared to controls (p < 0.0001). Chondrograft implants resulted in excellent defect filling with biomechanical function similar to normal healthy articular cartilage.
SN - 0736-0266
SN - 1554-527X
ER -