Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BY 4.0Journal of Bone and Joint Infection

A pre-specified surgical-complexity index is associated with a graded increase in periprosthetic joint infection after total knee arthroplasty: a competing-risks analysis using coronal alignment as a negative control

4 affiliations
  1. 1Northland Orthopaedic Research Consortium, Whangārei Hospital, Te Whatu Ora Te Tai Tokerau, Whangārei, Aotearoa, New Zealand
  2. 2Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Parkville, Victoria, Australia
  3. 3Northland Knee & Hip, Whangārei, Aotearoa, New Zealand
  4. 4Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri, USA

Abstract

Prediction of periprosthetic joint infection (PJI) after total knee arthroplasty (TKA) relies almost wholly on host factors, and whether the operation itself carries infection risk independent of the patient is unknown. We analyzed 2920 primary TKAs in 2350 patients from a single institution with national joint registry linkage, using death as a competing risk and coronal alignment as a negative-control exposure. A pre-specified surgical-complexity index counted five construct markers at the index operation: constraint, a tibial stem, a femoral stem, a previous implant and a pre-existing extra-articular deformity or fracture. Septic revision was the primary outcome and aseptic revision the control. Fine–Gray subdistribution hazard models with patient-level clustering estimated complexity and, in the paired-radiograph subset, neutral-alignment effects on both outcomes. There were 51 septic and 104 aseptic revisions and 525 deaths over a median follow-up of 7.4 years. Each additional complexity marker raised the subdistribution hazard of PJI (sHR 1.61, 95% CI 1.27–2.04) but not of aseptic revision (sHR 1.06, 95% CI 0.84–1.33); 5-year PJI incidence rose from 1.5% with zero or one marker to 5.9% with two or more. Neutral coronal alignment was protective against aseptic revision (sHR 0.42, 95% CI 0.26–0.67) but null for PJI (sHR 0.87, 95% CI 0.41–1.87). Adjustment for skin-to-skin operative time, available for 93% of the cohort, moved the complexity estimate in the same knees only from 1.58 to 1.55 and attributed 5 % of the effect to operative time. These are observational associations and not causal effects, but surgical exposure merits consideration alongside host factors in infection-risk assessment.

Related

  1. Tranexamic Acid Administration is Associated With Lower Transfusion Rates and Wound Complications Following Revision Total Knee Arthroplasty for Periprosthetic Joint Infection
    Pranit Kumaran, Julian Wier, Sahil S. Telang +4
    Arthroplasty TodayPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  2. Culture-Specific Outcomes of Intra-Articular Antibiotic Infusion With Implant-Retaining Debridement for Periprosthetic Joint Infection After Unicompartmental Knee Arthroplasty
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. From Measured Accuracy to Patient Outcome: Navigation in Total Hip Arthroplasty and Molecular Diagnosis of Periprosthetic Joint Infection: A Narrative Review
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Extensor Mechanism Reconstruction Following Periprosthetic Joint Infection After Total Knee Arthroplasty: A Systematic Review
    Camilla Prosenz, Hisham Fansa, Hannah Engel +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Implant sonication supporting the diagnosis of low-grade periprosthetic joint infection following reverse shoulder arthroplasty: a case report
    Gi-Won Seo, Kunil Seo, Yong-Beom Kim
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{hoskins2026prespecified,
  title = {{A pre-specified surgical-complexity index is associated with a graded increase in periprosthetic joint infection after total knee arthroplasty: a competing-risks analysis using coronal alignment as a negative control}},
  author = {Wayne Hoskins and Charles Gusho and Kenrick Rosser and Matthew Lim and Kate Dunstall and Kelly G. Vince},
  journal = {Journal of Bone and Joint Infection},
  year = {2026},
  month = nov,
  doi = {10.5194/jbji-11-705-2026},
  url = {https://doi.org/10.5194/jbji-11-705-2026},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - A pre-specified surgical-complexity index is associated with a graded increase in periprosthetic joint infection after total knee arthroplasty: a competing-risks analysis using coronal alignment as a negative control
AU  - Wayne Hoskins
AU  - Charles Gusho
AU  - Kenrick Rosser
AU  - Matthew Lim
AU  - Kate Dunstall
AU  - Kelly G. Vince
PY  - 2026
DA  - 2026/11/11
JO  - Journal of Bone and Joint Infection
DO  - 10.5194/jbji-11-705-2026
UR  - https://doi.org/10.5194/jbji-11-705-2026
AB  - Prediction of periprosthetic joint infection (PJI) after total knee arthroplasty (TKA) relies almost wholly on host factors, and whether the operation itself carries infection risk independent of the patient is unknown. We analyzed 2920 primary TKAs in 2350 patients from a single institution with national joint registry linkage, using death as a competing risk and coronal alignment as a negative-control exposure. A pre-specified surgical-complexity index counted five construct markers at the index operation: constraint, a tibial stem, a femoral stem, a previous implant and a pre-existing extra-articular deformity or fracture. Septic revision was the primary outcome and aseptic revision the control. Fine–Gray subdistribution hazard models with patient-level clustering estimated complexity and, in the paired-radiograph subset, neutral-alignment effects on both outcomes. There were 51 septic and 104 aseptic revisions and 525 deaths over a median follow-up of 7.4 years. Each additional complexity marker raised the subdistribution hazard of PJI (sHR 1.61, 95% CI 1.27–2.04) but not of aseptic revision (sHR 1.06, 95% CI 0.84–1.33); 5-year PJI incidence rose from 1.5% with zero or one marker to 5.9% with two or more. Neutral coronal alignment was protective against aseptic revision (sHR 0.42, 95% CI 0.26–0.67) but null for PJI (sHR 0.87, 95% CI 0.41–1.87). Adjustment for skin-to-skin operative time, available for 93% of the cohort, moved the complexity estimate in the same knees only from 1.58 to 1.55 and attributed 5 % of the effect to operative time. These are observational associations and not causal effects, but surgical exposure merits consideration alongside host factors in infection-risk assessment.
SN  - 2206-3552
ER  -