Development and internal evaluation of a nomogram for identifying current sleep disturbance in patients with colorectal cancer undergoing chemotherapy: a cross-sectional study.
5 affiliations
- 1School of Nursing, Chengdu Medical College, Chengdu, Sichuan, China.
- 2Mental Health Center of West China Hospital, Chengdu, Sichuan, China.
- 3State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Chengdu, Sichuan, China.
- 4Department of Oncology, The General Hospital of Western Theater Command, Chengdu, Sichuan, China.
- 5School of Nursing, Chengdu Medical College, Chengdu, Sichuan, China. [email protected].
Abstract
Objectives
This study aimed to identify factors associated with current sleep disturbance (SD) in patients with colorectal cancer (CRC) undergoing chemotherapy and to develop and internally evaluate a nomogram for estimating the probability of current SD.Methods
A total of 630 patients with CRC undergoing chemotherapy were recruited from five hospitals in China. Participants were assessed using the Demographic Information Questionnaire, Pittsburgh Sleep Quality Index (PSQI), and Hospital Anxiety and Depression Scale (HADS), while clinical assessment data and laboratory test results at admission were obtained from electronic medical records. The data were randomly divided into a training set and a validation set at a 7:3 ratio. Univariable analyses and multivariable logistic regression were used to identify factors associated with SD in patients with CRC undergoing chemotherapy. The training set was used for multivariable logistic regression modeling and nomogram development, whereas the validation set was used to evaluate the discrimination and calibration of the fixed model. In addition, 500 bootstrap resamples were performed within the training set for internal validation.Results
The overall prevalence of current SD was 68.7%. Gender, disease duration, ECOG performance status, HADS-D score, serum potassium, and albumin were independently associated with current SD and were included in the final nomogram. The model showed an AUC of 0.762 (95% CI, 0.716~0.808) in the training set and 0.712 (95% CI, 0.635~0.789) in the validation set. Bootstrap internal validation in the training set yielded a mean absolute calibration error of 0.022. In the validation set, the mean absolute calibration error (Eavg) was 0.055, with a calibration intercept of 0.318, a calibration slope of 0.667, and a Brier score of 0.188.Conclusions
Patients with CRC undergoing chemotherapy had a high burden of current SD. The nomogram may assist in identifying patients with a higher probability of current SD who may warrant further sleep assessment.
Related
- Development and Feasibility Evaluation of a Nurse-Led ePRO System for Home-Based Post-Chemotherapy Symptom Management in Patients With Cancer.
- Development and internal evaluation of models for screening kinesiophobia after hyperthermic intraperitoneal chemotherapy in patients with gastrointestinal cancer
- Prognostic value of the neutrophil-to-lymphocyte ratio in patients with colorectal cancer undergoing chemotherapy: a systematic review and meta-analysis
- Circulating Tumor DNA Status and Adjuvant Chemotherapy in Resected Colorectal Liver Metastases
- PDLIM4 increases sphingolipid accumulation to promote cancer stem cell characteristics and chemotherapy resistance in colorectal cancer
BibTeX
@article{tang2026development,
title = {{Development and internal evaluation of a nomogram for identifying current sleep disturbance in patients with colorectal cancer undergoing chemotherapy: a cross-sectional study.}},
author = {Ao Tang and Tian Xiao and Zhenrong Yin and Qing Li and Ruihan Xiao and Fangyi Li and Linyu Zhou and Biao He and Xiaoju Chen},
journal = {BMC gastroenterology},
year = {2026},
month = sep,
doi = {10.1186/s12876-026-05279-2},
url = {https://europepmc.org/article/MED/43079269},
note = {CC BY},
}
RIS
TY - JOUR
TI - Development and internal evaluation of a nomogram for identifying current sleep disturbance in patients with colorectal cancer undergoing chemotherapy: a cross-sectional study.
AU - Ao Tang
AU - Tian Xiao
AU - Zhenrong Yin
AU - Qing Li
AU - Ruihan Xiao
AU - Fangyi Li
AU - Linyu Zhou
AU - Biao He
AU - Xiaoju Chen
PY - 2026
DA - 2026/09/01
JO - BMC gastroenterology
DO - 10.1186/s12876-026-05279-2
UR - https://europepmc.org/article/MED/43079269
AB - Objectives This study aimed to identify factors associated with current sleep disturbance (SD) in patients with colorectal cancer (CRC) undergoing chemotherapy and to develop and internally evaluate a nomogram for estimating the probability of current SD.Methods A total of 630 patients with CRC undergoing chemotherapy were recruited from five hospitals in China. Participants were assessed using the Demographic Information Questionnaire, Pittsburgh Sleep Quality Index (PSQI), and Hospital Anxiety and Depression Scale (HADS), while clinical assessment data and laboratory test results at admission were obtained from electronic medical records. The data were randomly divided into a training set and a validation set at a 7:3 ratio. Univariable analyses and multivariable logistic regression were used to identify factors associated with SD in patients with CRC undergoing chemotherapy. The training set was used for multivariable logistic regression modeling and nomogram development, whereas the validation set was used to evaluate the discrimination and calibration of the fixed model. In addition, 500 bootstrap resamples were performed within the training set for internal validation.Results The overall prevalence of current SD was 68.7%. Gender, disease duration, ECOG performance status, HADS-D score, serum potassium, and albumin were independently associated with current SD and were included in the final nomogram. The model showed an AUC of 0.762 (95% CI, 0.716~0.808) in the training set and 0.712 (95% CI, 0.635~0.789) in the validation set. Bootstrap internal validation in the training set yielded a mean absolute calibration error of 0.022. In the validation set, the mean absolute calibration error (Eavg) was 0.055, with a calibration intercept of 0.318, a calibration slope of 0.667, and a Brier score of 0.188.Conclusions Patients with CRC undergoing chemotherapy had a high burden of current SD. The nomogram may assist in identifying patients with a higher probability of current SD who may warrant further sleep assessment.
SN - 1471-230X
ER -