Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 39 min ago
PreprintCC BY-NCbioRxiv

Stainless Steel vs Calcium Fluoride for biomedical Raman Spectroscopy

  1. 1University College London

Abstract

Raman spectroscopy (RS) has been shown to differentiate various disease states in tissue samples, yet the impact of sample substrate on spectral quality and downstream machine-learning (ML) performance is under-explored. We collected 960 spectra from 36 formalin-fixed, paraffin-embedded colonic specimens mounted in parallel on calcium fluoride (CaF2) and mirrored stainless-steel (SS) slides. Raw SS spectra were more intense than CaF2, and routine dewaxing left prominent paraffin peaks on CaF2 that were largely absent on SS. Extending CaF2 xylene immersion to 48 h reduced key paraffin peaks by 11 to 23%, aligning its biochemical profile with SS. Nested cross-validated classifiers were built to distinguish true disease (T1) from epithelial misplacement (EM). The highest accuracies were observed on SS (0.65 - 0.66), while CaF2 improved from 0.41 - 0.57 to 0.65 - 0.69 after extended dewaxing, chiefly via gains in recall. Although optimal dewaxing renders CaF2 diagnostically non-inferior, SS still offers superior accuracy, faster preparation, at approximately 4% of the cost, supporting its integration into scalable, AI-enabled RS pathology workflows.

Related

  1. Viable but Nonculturable Listeria monocytogenes May Resuscitate After Transfer From Stainless Steel Biofilms to Vacuum-Packed Smoked Herring
    Thomas Brauge, Guylaine Leleu, Aurélie Hanin
    Journal of Food ProtectionPeer-reviewedCC BY-NC-ND 4.0Full textMolecular biology & gene regulationMicrobiologyHAL
  2. Asymmetry-induced distinct mechanisms and the transporting role of sodium in bacterial fluoride channel Fluc
    Fernando Montalvillo Ortega, Kira Mills, Hedieh Torabifard
    Nature CommunicationsPeer-reviewedCC BY-NC-ND 4.0Full textMolecular biology & gene regulationCrossref
  3. Optimisation and Validation of a UHPLC-MS/MS Assay Using Timed Post-Column Ammonium Fluoride Infusion for Sensitive Serum Steroids Quantitation
    V. Dosedelova, J. M. Hawley, E. Melson +3
    bioRxivPreprintCC BYFull textGeneral biochemistrybioRxiv
  4. Effects of Hydroxyapatite Pretreated with Two Sodium Fluoride Concentrations on Early Bone Healing in Beagle Dogs
    Yoshino Suzuki, Ujjal K. Bhawal, Aman Chowdhry +3
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0General biochemistryCrossref
  5. DICD-IE: an expert-annotated benchmark for evaluating pretrained biomedical language models in dental implant literature and clinical knowledge extraction
    Almonzer Salah Nooraldaim, Azza A. Abushama, Hiba Ahmed +7
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMolecular biology & gene regulationCrossref
BibTeX
@misc{ng2026stainless,
  title = {{Stainless Steel vs Calcium Fluoride for biomedical Raman Spectroscopy}},
  author = {C. Ng and N. Blake and G. Thomas},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.09.753418},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.09.753418v1},
  note = {CC BY-NC},
}
RIS
TY  - UNPB
TI  - Stainless Steel vs Calcium Fluoride for biomedical Raman Spectroscopy
AU  - C. Ng
AU  - N. Blake
AU  - G. Thomas
PY  - 2026
DA  - 2026/10/09
PB  - bioRxiv
DO  - 10.64898/2026.10.09.753418
UR  - https://www.biorxiv.org/content/10.64898/2026.10.09.753418v1
AB  - Raman spectroscopy (RS) has been shown to differentiate various disease states in tissue samples, yet the impact of sample substrate on spectral quality and downstream machine-learning (ML) performance is under-explored. We collected 960 spectra from 36 formalin-fixed, paraffin-embedded colonic specimens mounted in parallel on calcium fluoride (CaF2) and mirrored stainless-steel (SS) slides. Raw SS spectra were more intense than CaF2, and routine dewaxing left prominent paraffin peaks on CaF2 that were largely absent on SS. Extending CaF2 xylene immersion to 48 h reduced key paraffin peaks by 11 to 23%, aligning its biochemical profile with SS. Nested cross-validated classifiers were built to distinguish true disease (T1) from epithelial misplacement (EM). The highest accuracies were observed on SS (0.65 - 0.66), while CaF2 improved from 0.41 - 0.57 to 0.65 - 0.69 after extended dewaxing, chiefly via gains in recall. Although optimal dewaxing renders CaF2 diagnostically non-inferior, SS still offers superior accuracy, faster preparation, at approximately 4% of the cost, supporting its integration into scalable, AI-enabled RS pathology workflows.
ER  -