Right internal jugular approach for transcatheter edge-to-edge mitral valve repair using the MitraClip G4 system after failed transfemoral access: a case report

Abstract

Background: Transcatheter edge-to-edge repair of the mitral valve is conventionally performed via transfemoral venous access. When this route is not feasible, the right internal jugular vein may provide an alternative, but procedural experience remains limited.

Case summary: A 93-year-old woman with refractory heart failure had atrial functional mitral regurgitation and low-flow, low-gradient aortic stenosis. After transcatheter aortic valve implantation, moderate-to-severe mitral regurgitation persisted. Transfemoral edge-to-edge repair was unsuccessful because severe iliac venous tortuosity prevented adequate catheter control. The procedure was subsequently performed via the right internal jugular vein using the MitraClip G4 system. A pre-existing iatrogenic atrial septal defect was reused, and temporary left ventricular apical wire support facilitated advancement of the steerable guiding catheter into the left atrium. Stepwise + knob rotation increased height and working space, improved the markedly under-straddled configuration, and permitted further advancement of the clip delivery system. Subsequent M- and P-knob adjustments achieved an appropriate trajectory towards A2/P2, with an S-shaped fluoroscopic configuration. Leaflet grasping reduced mitral regurgitation to mild without access-site complications. Mild mitral regurgitation was maintained at 6 months without heart-failure rehospitalization.

Discussion: Right internal jugular access may be a feasible alternative when transfemoral access is not possible. Successful navigation requires recognition of access-specific catheter behaviour and adaptation of steering under real-time fluoroscopy and transoesophageal echocardiography. An S-shaped fluoroscopic configuration may serve as a practical landmark of a favourable trajectory towards the mitral valve.

Related

  1. Fluoroscopic Catheter-Tip Positioning During Internal Jugular TIVAD Placement in Breast Cancer: A Two-Center Retrospective Cohort Study
    Zeyang Fan, Kai Yang
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Internal jugular vein approach facilitating second leadless pacemaker implantation after battery depletion
    Nobuhiko Ueda, Kohei Ishibashi, Akinori Wakamiya +2
    Journal of Cardiology CasesPeer-reviewedLicence not statedFull textCardiovascular medicinePMC
  3. Outcomes of Surgical Versus Transcatheter Mitral Valve Repair or Replacement in Patients With Myocardial Infarction and Concomitant Mitral Regurgitation: A Retrospective Analysis of Real-World Data
    Judah Rajendran, Akiva Rosenzveig, Nishitha Vempalli +6
    Journal of the Society for Cardiovascular Angiography & InterventionsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMCEurope PMC
  4. Right mainstem intubation improves transoesophageal echocardiographic guidance during mitral transcatheter edge-to-edge repair
    Yasuhisa Nakao, Kazuhisa Nishimura, Katsuji Inoue +1
    European Heart Journal. Case ReportsPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
  5. Sex Differences in Referral Timing for Mitral Transcatheter Edge-to-Edge Repair: A Retrospective Cohort Study
    Saliha Erdem, Anas Hashem, Chloe Kharsa +4
    Journal of the Society for Cardiovascular Angiography & InterventionsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMCEurope PMC
BibTeX
@article{konami2026right,
  title = {{Right internal jugular approach for transcatheter edge-to-edge mitral valve repair using the MitraClip G4 system after failed transfemoral access: a case report}},
  author = {Yutaka Konami and Kazuhisa Kodama and Mika Maeda and Masahiro Yamada and Tomohiro Sakamoto},
  journal = {European Heart Journal. Case Reports},
  year = {2026},
  month = oct,
  doi = {10.1093/ehjcr/ytag756},
  url = {https://doi.org/10.1093/ehjcr/ytag756},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Right internal jugular approach for transcatheter edge-to-edge mitral valve repair using the MitraClip G4 system after failed transfemoral access: a case report
AU  - Yutaka Konami
AU  - Kazuhisa Kodama
AU  - Mika Maeda
AU  - Masahiro Yamada
AU  - Tomohiro Sakamoto
PY  - 2026
DA  - 2026/10/01
JO  - European Heart Journal. Case Reports
DO  - 10.1093/ehjcr/ytag756
UR  - https://doi.org/10.1093/ehjcr/ytag756
AB  - Background: Transcatheter edge-to-edge repair of the mitral valve is conventionally performed via transfemoral venous access. When this route is not feasible, the right internal jugular vein may provide an alternative, but procedural experience remains limited.  Case summary: A 93-year-old woman with refractory heart failure had atrial functional mitral regurgitation and low-flow, low-gradient aortic stenosis. After transcatheter aortic valve implantation, moderate-to-severe mitral regurgitation persisted. Transfemoral edge-to-edge repair was unsuccessful because severe iliac venous tortuosity prevented adequate catheter control. The procedure was subsequently performed via the right internal jugular vein using the MitraClip G4 system. A pre-existing iatrogenic atrial septal defect was reused, and temporary left ventricular apical wire support facilitated advancement of the steerable guiding catheter into the left atrium. Stepwise + knob rotation increased height and working space, improved the markedly under-straddled configuration, and permitted further advancement of the clip delivery system. Subsequent M- and P-knob adjustments achieved an appropriate trajectory towards A2/P2, with an S-shaped fluoroscopic configuration. Leaflet grasping reduced mitral regurgitation to mild without access-site complications. Mild mitral regurgitation was maintained at 6 months without heart-failure rehospitalization.  Discussion: Right internal jugular access may be a feasible alternative when transfemoral access is not possible. Successful navigation requires recognition of access-specific catheter behaviour and adaptation of steering under real-time fluoroscopy and transoesophageal echocardiography. An S-shaped fluoroscopic configuration may serve as a practical landmark of a favourable trajectory towards the mitral valve.
SN  - 2514-2119
ER  -