Self-designed dynamic external fixation frame with limited closed reduction by Kirschner wire for the treatment of interphalangeal joint fracture-dislocations: a cohort study
- 1Department of orthopedics, The Affiliated Taizhou people's Hospital of Nanjing Medical University, Taizhou School of Clinical Medicine, Nanjing Medical University, Taizhou Key Laboratory for Prevention and Treatment of Orthopedic Chronic Diseases, Taizhou, Jiangsu, China.
Abstract
Background
Interphalangeal (IP) joint fracture-dislocations are common hand injuries that can lead to joint instability, degenerative arthritis, joint stiffness, persistent pain, and decreased strength. We proposed the application of a self-designed dynamic external fixation with limited closed reduction using Kirschner wires. The objective of this study was to investigate the clinical efficacy of this technique in the treatment of IP joint fracture-dislocations of the proximal and distal IP joints.Methods
This retrospective study involved 44 patients who were treated for IP joint fracture-dislocations from February 2023 to November 2024. The study recorded and compared various metrics, including the Visual analog Scale (VAS) and range of motion (ROM) of the IP joint, both preoperatively and at the final follow-up.Results
All 44 patients were followed up after surgery for 12-23 months, with an average of (16.0 ± 3.1) months. All patients successfully completed the operation and were discharged from the hospital 3-5 days after the operation, with an average hospitalization time of (4.2 ± 0.8) days. The operative time was 30-50 minutes, with an average of (38.4 ± 5.9) minutes. During the follow-up period, all 44 patients healed successfully. One case exhibited finger joint angulation, and two cases experienced pin tract exudation. These were corrected by timely adjustment of Kirschner wires and tension, as well as anti-inflammatory treatment. No other complications, such as wire breakage, pin-tract infection, or fracture nonunion, were observed. At the final follow-up, the patients' VAS scores were significantly lower, while the ROM values were significantly higher, and these differences were statistically significant (P < 0.05).Conclusion
The self-designed Kirschner wire external fixation frame combined with limited closed internal fixation for the treatment of IP joint fractures and dislocations is convenient and cost-effective; it provides reliable fixation, allows dynamic adjustment, minimizes trauma, promotes fracture healing, and facilitates the recovery of joint function. It is an ideal internal fixation method that is worthy of clinical promotion.
Related
- Unburied Versus Buried Kirschner Wires in the Traumatic Osteosynthesis of the Upper Limb in Pediatric Patients: A Retrospective Cohort
- Twenty-Year Outcomes After Hemi-Hamate Resurfacing Arthroplasty of the Proximal Interphalangeal Joint
- A comparative study of Kirschner wire intramedullary fixation versus bicortical fixation for metaphyseal-diaphyseal junction fractures of the pediatric distal radius.
- Minimally invasive biological fixation of comminuted navicular fracture using semi-circular external fixator combined with Kirschner wire: a case report.
- Distal Interphalangeal Joint Arthrodesis: A Systematic Review of 3 Common Fixation Techniques.
BibTeX
@article{zhou2026selfdesigned,
title = {{Self-designed dynamic external fixation frame with limited closed reduction by Kirschner wire for the treatment of interphalangeal joint fracture-dislocations: a cohort study}},
author = {Zhiyong Zhou and Weihao Zhu and Xu Sun and Weiwei Jiang and Zhengming Lv},
journal = {Annals of medicine and surgery (2012)},
year = {2026},
month = sep,
doi = {10.1097/ms9.0000000000005671},
url = {https://europepmc.org/article/PMC/PMC13754336},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Self-designed dynamic external fixation frame with limited closed reduction by Kirschner wire for the treatment of interphalangeal joint fracture-dislocations: a cohort study
AU - Zhiyong Zhou
AU - Weihao Zhu
AU - Xu Sun
AU - Weiwei Jiang
AU - Zhengming Lv
PY - 2026
DA - 2026/09/30
JO - Annals of medicine and surgery (2012)
DO - 10.1097/ms9.0000000000005671
UR - https://europepmc.org/article/PMC/PMC13754336
AB - Background Interphalangeal (IP) joint fracture-dislocations are common hand injuries that can lead to joint instability, degenerative arthritis, joint stiffness, persistent pain, and decreased strength. We proposed the application of a self-designed dynamic external fixation with limited closed reduction using Kirschner wires. The objective of this study was to investigate the clinical efficacy of this technique in the treatment of IP joint fracture-dislocations of the proximal and distal IP joints.Methods This retrospective study involved 44 patients who were treated for IP joint fracture-dislocations from February 2023 to November 2024. The study recorded and compared various metrics, including the Visual analog Scale (VAS) and range of motion (ROM) of the IP joint, both preoperatively and at the final follow-up.Results All 44 patients were followed up after surgery for 12-23 months, with an average of (16.0 ± 3.1) months. All patients successfully completed the operation and were discharged from the hospital 3-5 days after the operation, with an average hospitalization time of (4.2 ± 0.8) days. The operative time was 30-50 minutes, with an average of (38.4 ± 5.9) minutes. During the follow-up period, all 44 patients healed successfully. One case exhibited finger joint angulation, and two cases experienced pin tract exudation. These were corrected by timely adjustment of Kirschner wires and tension, as well as anti-inflammatory treatment. No other complications, such as wire breakage, pin-tract infection, or fracture nonunion, were observed. At the final follow-up, the patients' VAS scores were significantly lower, while the ROM values were significantly higher, and these differences were statistically significant (P < 0.05).Conclusion The self-designed Kirschner wire external fixation frame combined with limited closed internal fixation for the treatment of IP joint fractures and dislocations is convenient and cost-effective; it provides reliable fixation, allows dynamic adjustment, minimizes trauma, promotes fracture healing, and facilitates the recovery of joint function. It is an ideal internal fixation method that is worthy of clinical promotion.
SN - 2049-0801
ER -