Frequency-swept Brillouin spectroscopy

Abstract

Spontaneous Brillouin microscopy provides non-contact access to the viscoelastic properties of materials. Standard measurements typically utilize a single-wavelength continuous-wave laser to illuminate a specimen and excites a spontaneous Brillouin scattering signal, which is then recorded by a spectrometer. Existing Brillouin spectrometers are mostly built around either a scanning Fabry-Pérot etalon or a virtually imaged phased array (VIPA) etalon. While performing well, these setups are bulky and demand significant optical expertise to construct and maintain. Here, we propose a new approach to conducting Brillouin spectroscopy. In this approach, a frequency-swept laser excites a series of Brillouin spectra with incrementally shifted central frequencies, while a frequency picker, consisting of a narrow bandpass filter and a highly sensitive single-photon detector, sequentially records each spectral component to reconstruct the full spectrum. We demonstrate that the frequency-swept Brillouin spectroscopy can run under shot-noise limited condition using standard samples. Compared with conventional spectrometers, our system features a much more compact design for portable applications and holds potential for rapid mechanical imaging through multiplexing.

Related

  1. Recovery of event boundaries and Brillouin frequency shift in STFT-BOTDR using variable projection with spatial response constraint
    Haoran Gao, Junxian Liu, Qirong Xu +6
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  2. Elastic Properties of Titan Tholins Revealed by Brillouin Spectroscopy
    Mark A. Johnson, Jose R. Montes-Bojorquez, Adis Husic +7
    arXivPreprintCC BY-NC-SA 4.0Full textInstrumentation & methodsPlanetary science & exoplanetsarXiv
  3. Influence of pump-probe beam offset and modulation frequency on photothermal deflection spectroscopy signals in liquid sensing: A combined theoretical and experimental study
    Sebin Binu, Gabriel Oliveira, Dominik Kau-Wacht +3
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Raman Transitions in Collinear Laser Spectroscopy for High-Precision Frequency Measurements
    Julien Spahn, Hendrik Bodnar, Kristian König +2
    arXivPreprintarXiv licenceFull textAtomic, molecular & optical physicsarXiv
  5. Pair-Condensation Peak in Radio-Frequency Dimer-Projection Spectroscopy of a Unitary Fermi Gas
    Zhixiu Peng, Zhenhua Yu
    arXivPreprintCC BY 4.0Full textAtomic, molecular & optical physicsCondensed matterarXiv
BibTeX
@misc{kang2026frequencyswept,
  title = {{Frequency-swept Brillouin spectroscopy}},
  author = {Lin Kang and Shahrin Jahan Jaima and Jitao Zhang},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.21574},
  eprint = {2609.21574},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.21574},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Frequency-swept Brillouin spectroscopy
AU  - Lin Kang
AU  - Shahrin Jahan Jaima
AU  - Jitao Zhang
PY  - 2026
DA  - 2026/09/18
PB  - arXiv
DO  - 10.48550/arxiv.2609.21574
UR  - https://arxiv.org/abs/2609.21574
AB  - Spontaneous Brillouin microscopy provides non-contact access to the viscoelastic properties of materials. Standard measurements typically utilize a single-wavelength continuous-wave laser to illuminate a specimen and excites a spontaneous Brillouin scattering signal, which is then recorded by a spectrometer. Existing Brillouin spectrometers are mostly built around either a scanning Fabry-Pérot etalon or a virtually imaged phased array (VIPA) etalon. While performing well, these setups are bulky and demand significant optical expertise to construct and maintain. Here, we propose a new approach to conducting Brillouin spectroscopy. In this approach, a frequency-swept laser excites a series of Brillouin spectra with incrementally shifted central frequencies, while a frequency picker, consisting of a narrow bandpass filter and a highly sensitive single-photon detector, sequentially records each spectral component to reconstruct the full spectrum. We demonstrate that the frequency-swept Brillouin spectroscopy can run under shot-noise limited condition using standard samples. Compared with conventional spectrometers, our system features a much more compact design for portable applications and holds potential for rapid mechanical imaging through multiplexing.
ER  -