A feasible and cost-effective method to induce distal radius fractures in full-length forearm human cadaveric specimens
9 affiliations
- 1Trauma Orthopaedic Research Copenhagen Hvidovre (TORCH), Department of Orthopaedic Surgery, Copenhagen University Hospital – Amager and Hvidovre, Hvidovre, Denmark
- 2Center for Musculoskeletal Surgery, Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- 3Berlin Institute of Health at Charité – Universitätsmedizin Berlin, Julius Wolff Institute, Berlin, Germany
- 4Exo360, Copenhagen, Denmark
- 5Department of Orthopaedic Surgery, Copenhagen University Hospital – Bispebjerg, Copenhagen, Denmark
- 6Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- 7Department of Orthopaedic Surgery, Brigham and Women’s Hospital, MassGeneral Brigham Harvard Medical School, Boston, USA
- 8Department of Orthopaedic Surgery, Copenhagen University Hospital – North Zealand Hospital, Hillerød, Denmark
- 9Steno Diabetes Center Copenhagen, Copenhagen, Denmark
Abstract
Introduction: Reported rates of loss of reduction in nonoperatively treated distal radius fractures (DRF) range from 17 to 71%. Thus, realistic biomechanical models are warranted to test novel immobilization devices that prevent loss of reduction in nonoperative fracture management. Currently available human cadaveric specimen models have several limitations: (i) disrupted soft tissue integrity, (ii) difficulty in replicating complex fracture patterns, and (iii) high technical demands and costs. Therefore, the aim of this study was to establish a feasible and accessible method for inducing DRFs, that accurately reflects in-vivo biomechanical fracture conditions in tissue-intact cadaveric specimens, suitable for testing of novel immobilization devices.
Materials and methods: Fifteen upper extremity cadaveric specimens were included. Specimens were prepared as full‑length forearm models. Using a repurposed strength training tower as a vertical drop tower, fractures were induced by proximally administering 120–135 J impacts. CT scans were performed pre- and post-fracture induction. All fractures were classified according to the AO/OTA classification.
Results: DRFs were successfully induced in all 15 specimens. A single 120 J impact produced a DRF in 11 out of 15 cases (73%). A second impact was administered in 4 out of 15 specimens (27%). Eleven of the 15 induced DRFs (73%) were classified as AO/OTA type C fractures, most commonly 2R3C3.2. Concomitant distal ulnar fractures were present in 6 cases, concomitant carpal fractures in 9 specimens. The overall cost of the setup amounted to 947 €.
Conclusions: This study presents a feasible, cost-effective method to induce DRFs in tissue-intact, full-length human cadaveric forearm specimens. The setup consistently produces DRFs, predominantly AO/OTA type C, which can, with certain limitations, be utilized for biomechanical testing of immobilization devices, while also being uited for surgical and anatomical education.
Related
- Comparative anatomical and ultrasonographic analysis of the accessory parotid gland in cadaveric specimens
- Rotational behaviour and morphological associations of the CT-based distal ulnar centering and eccentricity (DUCE) method in cadaveric specimens
- Addition of a McLaughlin cerclage to locking plate fixation of distal patellar pole fractures reduces interfragmentary displacement – a biomechanical human cadaveric study
- Routine Forearm Cast Splitting in Pediatric Patients Following Closed Reduction
- Clot Removal from Distal Part in Microvascular Radial Forearm Free Flap: Technical Note
BibTeX
@article{kruger2026feasible,
title = {{A feasible and cost-effective method to induce distal radius fractures in full-length forearm human cadaveric specimens}},
author = {Julius Krüger and Mads Terndrup and Morten Grove Thomsen and Arvind von Keudell and Jonas Askø Andersen and Tazio Maleitzke},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2026},
month = nov,
doi = {10.1007/s00402-026-06549-0},
url = {https://doi.org/10.1007/s00402-026-06549-0},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - A feasible and cost-effective method to induce distal radius fractures in full-length forearm human cadaveric specimens
AU - Julius Krüger
AU - Mads Terndrup
AU - Morten Grove Thomsen
AU - Arvind von Keudell
AU - Jonas Askø Andersen
AU - Tazio Maleitzke
PY - 2026
DA - 2026/11/03
JO - Archives of Orthopaedic and Trauma Surgery
DO - 10.1007/s00402-026-06549-0
UR - https://doi.org/10.1007/s00402-026-06549-0
AB - Introduction: Reported rates of loss of reduction in nonoperatively treated distal radius fractures (DRF) range from 17 to 71%. Thus, realistic biomechanical models are warranted to test novel immobilization devices that prevent loss of reduction in nonoperative fracture management. Currently available human cadaveric specimen models have several limitations: (i) disrupted soft tissue integrity, (ii) difficulty in replicating complex fracture patterns, and (iii) high technical demands and costs. Therefore, the aim of this study was to establish a feasible and accessible method for inducing DRFs, that accurately reflects in-vivo biomechanical fracture conditions in tissue-intact cadaveric specimens, suitable for testing of novel immobilization devices. Materials and methods: Fifteen upper extremity cadaveric specimens were included. Specimens were prepared as full‑length forearm models. Using a repurposed strength training tower as a vertical drop tower, fractures were induced by proximally administering 120–135 J impacts. CT scans were performed pre- and post-fracture induction. All fractures were classified according to the AO/OTA classification. Results: DRFs were successfully induced in all 15 specimens. A single 120 J impact produced a DRF in 11 out of 15 cases (73%). A second impact was administered in 4 out of 15 specimens (27%). Eleven of the 15 induced DRFs (73%) were classified as AO/OTA type C fractures, most commonly 2R3C3.2. Concomitant distal ulnar fractures were present in 6 cases, concomitant carpal fractures in 9 specimens. The overall cost of the setup amounted to 947 €. Conclusions: This study presents a feasible, cost-effective method to induce DRFs in tissue-intact, full-length human cadaveric forearm specimens. The setup consistently produces DRFs, predominantly AO/OTA type C, which can, with certain limitations, be utilized for biomechanical testing of immobilization devices, while also being uited for surgical and anatomical education.
SN - 0936-8051
SN - 1434-3916
ER -