Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 1 h ago
Peer-reviewedCC BY-NC-ND 4.0JACC Case Reports

Optimizing Leadless Atrial Pacemaker Performance Through Strategic Reprogramming

  1. 1HonorHealth Research Institute and HonorHealth, Scottsdale, Arizona, USA
  2. 2Arizona State University Edson College of Nursing and Health Innovation, Phoenix, Arizona, USA
  3. 3Arizona State University John Shufeldt School of Medicine and Medical Engineering, Phoenix, Arizona, USA

Abstract

Background: Although implantation strategies for dual-chamber leadless pacemakers are well documented, long-term management, particularly concerning battery longevity, remains under observation. Atrial leadless pacemaker battery life is shorter than that of its ventricular counterpart in real-world observations without clear guidelines established for postimplantation programming.

Project Rationale: We undertook a quality improvement initiative in our outpatient device clinic to address battery longevity in leadless pacemakers via programming approaches targeting 6 optimization areas. A step-by-step algorithm was developed for device clinic staff.

Project Summary: Twenty patients underwent algorithm-driven reprogramming by device clinic staff, with the average battery life increasing by 1.41 years to 5.48 years, a 33.7% improvement. Repeat interrogation at 90 days showed consistent longevity readings (5.4 years).

Take-Home Messages: Dual-chamber leadless pacemakers require refined programming strategies. Implementing a structured algorithm in an outpatient device clinic enabled clinic staff to tailor settings for each patient, resulting in a substantial increase in battery life.

Related

  1. Multiple right ventricular pseudoaneurysms after helix-fixation leadless pacemaker implantation.
    Kosuke Hirose, Satoshi Oka, Nobuhiko Ueda +3
    HeartRhythm case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Challenging case of leadless pacemaker implantation for a patient with left-sided inferior vena cava.
    Yuki Tanaka, Masaru Yamaki, Yoshifumi Mizuguchi +1
    HeartRhythm case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. Internal jugular vein approach facilitating second leadless pacemaker implantation after battery depletion
    Nobuhiko Ueda, Kohei Ishibashi, Akinori Wakamiya +2
    Journal of Cardiology CasesPeer-reviewedLicence not statedFull textCardiovascular medicinePMC
  4. Helix-based retrieval of an embolized atrial leadless pacemaker from the pulmonary artery.
    Takeaki Goto, Kenji Kuroki, Chisa Asahina +3
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  5. Successful Bailout Retrieval of an Active‐Fixation Atrial Leadless Pacemaker Following Suspected Tissue Entrapment During Repositioning
    Toshiya Yoshida, Akira Kasagawa, Daisuke Togashi +2
    Journal of arrhythmiaPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
BibTeX
@article{kleinhans2026optimizing,
  title = {{Optimizing Leadless Atrial Pacemaker Performance Through Strategic Reprogramming}},
  author = {Amy Kleinhans and Heather M. Ross and Fantasia Hudson and Rahul N. Doshi},
  journal = {JACC Case Reports},
  year = {2026},
  month = sep,
  doi = {10.1016/j.jaccas.2026.109730},
  url = {https://doi.org/10.1016/j.jaccas.2026.109730},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Optimizing Leadless Atrial Pacemaker Performance Through Strategic Reprogramming
AU  - Amy Kleinhans
AU  - Heather M. Ross
AU  - Fantasia Hudson
AU  - Rahul N. Doshi
PY  - 2026
DA  - 2026/09/16
JO  - JACC Case Reports
DO  - 10.1016/j.jaccas.2026.109730
UR  - https://doi.org/10.1016/j.jaccas.2026.109730
AB  - Background: Although implantation strategies for dual-chamber leadless pacemakers are well documented, long-term management, particularly concerning battery longevity, remains under observation. Atrial leadless pacemaker battery life is shorter than that of its ventricular counterpart in real-world observations without clear guidelines established for postimplantation programming.  Project Rationale: We undertook a quality improvement initiative in our outpatient device clinic to address battery longevity in leadless pacemakers via programming approaches targeting 6 optimization areas. A step-by-step algorithm was developed for device clinic staff.  Project Summary: Twenty patients underwent algorithm-driven reprogramming by device clinic staff, with the average battery life increasing by 1.41 years to 5.48 years, a 33.7% improvement. Repeat interrogation at 90 days showed consistent longevity readings (5.4 years).  Take-Home Messages: Dual-chamber leadless pacemakers require refined programming strategies. Implementing a structured algorithm in an outpatient device clinic enabled clinic staff to tailor settings for each patient, resulting in a substantial increase in battery life.
SN  - 2666-0849
ER  -