Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 1 min ago
Peer-reviewedCC BY-NC-NDQuantitative imaging in medicine and surgery

Automated quantitative computed tomography grading of lumbar facet joint degeneration: influence of segmentation errors on instance-level clinical assessment.

  1. 1Department of Orthopedics, Affiliated Nantong Clinical College of Nantong University, Nantong First People's Hospital, School of Medicine, Nantong University, Nantong, China.
  2. 2Department of Orthopedics, Nantong First People's Hospital, Southeast University, Nantong, China.

Abstract

Automated lumbar facet joint degeneration grading requires both accurate anatomical segmentation and clinically meaningful region-level classification. We evaluated whether voxel-level segmentation performance was aligned with downstream degeneration grading. This retrospective study included 145 lumbar computed tomography (CT) examinations and 725 level-specific bilateral facet joint regions of interest (ROIs), including 165 severe and 560 non-severe regions. Weishaupt grades 0-1 were categorized as non-severe and grades 2-3 as severe. Scheme A used binary nnU-Net segmentation followed by 11 quantitative region-level features, training-fold-specific standardization, and logistic regression; an oracle comparison using ground-truth masks was compared with analysis using predicted masks. Scheme B used direct three-class segmentation. Patient-level five-fold cross-validation was performed, with 116 training and 29 validation patients per fold. The results were reported as mean ± standard deviation (SD). Scheme A achieved a binary segmentation Dice coefficient of 0.770±0.008. In the oracle comparison, the region-level area under the receiver operating characteristic (ROC) curve (AUC), recall, F1-score, accuracy, and case-level accuracy were 0.671±0.100, 0.538±0.172, 0.399±0.102, 0.640±0.051, and 0.579±0.096, respectively. Using predicted masks, the corresponding values were 0.650±0.068, 0.603±0.250, 0.375±0.072, 0.563±0.123, and 0.545±0.071. Scheme B achieved a native nnU-Net mean validation Dice of 0.493±0.044 and region-level AUC, recall, F1-score, accuracy, and case-level accuracy of 0.730±0.024, 0.445±0.051, 0.510±0.045, 0.808±0.015, and 0.738±0.058, respectively. Voxel-level segmentation and clinically oriented grading performance were not directly aligned. Scheme A provided stable anatomical segmentation but more variable downstream grading, whereas scheme B achieved better overall region- and case-level classification performance but lower severe-degeneration recall. Both spatial and clinical decision metrics should therefore be considered when evaluating automated facet joint grading systems.

Related

  1. Automated joint segmentation enables quantitative molecular imaging of degeneration with [¹⁸F]FDG and [¹⁸F]NaF PET/CT
    William K. Lee, Shiv Patil, Darshil H. Patel +6
    European Journal of Nuclear Medicine and Molecular ImagingPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMC
  2. Automated segmentation and clinical characterization of layered plaque in intracoronary optical coherence tomography
    Ruben G.A. van der Waerden, Joske L. van der Zande, Simone Saitta +23
    International journal of cardiology. Heart & vasculaturePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. Association of sarcopenia with treatment tolerance in older adults with acute myeloid leukemia using artificial intelligence computed tomography–segmentation and a geriatric assessment
    Samuel J. Yates, Elizabeth Terman, Lauren Miller +17
    LeukemiaPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  4. A novel morphological assessment approach for abdominal aortic aneurysms: automated segmentation and measurement using a semi-supervised deep learning algorithm
    Guangkuo Wang, Jingyi Zeng, Min Li +3
    Frontiers in cardiovascular medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMCCrossref
  5. Quantitative assessment of aortic wall thickening disease by dual energy computed tomography angiography.
    Na Li, Jia Liu, Qinyue Luo +4
    BMC medical imagingPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
BibTeX
@article{chen2026automated,
  title = {{Automated quantitative computed tomography grading of lumbar facet joint degeneration: influence of segmentation errors on instance-level clinical assessment.}},
  author = {Baisen Chen and Yukang Cheng and Chunyan Ji and Zhiming Cui and Guanhua Xu and Yuyu Sun},
  journal = {Quantitative imaging in medicine and surgery},
  year = {2026},
  month = oct,
  doi = {10.21037/qims-2026-1485},
  url = {https://europepmc.org/article/MED/42997901},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Automated quantitative computed tomography grading of lumbar facet joint degeneration: influence of segmentation errors on instance-level clinical assessment.
AU  - Baisen Chen
AU  - Yukang Cheng
AU  - Chunyan Ji
AU  - Zhiming Cui
AU  - Guanhua Xu
AU  - Yuyu Sun
PY  - 2026
DA  - 2026/10/20
JO  - Quantitative imaging in medicine and surgery
DO  - 10.21037/qims-2026-1485
UR  - https://europepmc.org/article/MED/42997901
AB  - Automated lumbar facet joint degeneration grading requires both accurate anatomical segmentation and clinically meaningful region-level classification. We evaluated whether voxel-level segmentation performance was aligned with downstream degeneration grading. This retrospective study included 145 lumbar computed tomography (CT) examinations and 725 level-specific bilateral facet joint regions of interest (ROIs), including 165 severe and 560 non-severe regions. Weishaupt grades 0-1 were categorized as non-severe and grades 2-3 as severe. Scheme A used binary nnU-Net segmentation followed by 11 quantitative region-level features, training-fold-specific standardization, and logistic regression; an oracle comparison using ground-truth masks was compared with analysis using predicted masks. Scheme B used direct three-class segmentation. Patient-level five-fold cross-validation was performed, with 116 training and 29 validation patients per fold. The results were reported as mean ± standard deviation (SD). Scheme A achieved a binary segmentation Dice coefficient of 0.770±0.008. In the oracle comparison, the region-level area under the receiver operating characteristic (ROC) curve (AUC), recall, F1-score, accuracy, and case-level accuracy were 0.671±0.100, 0.538±0.172, 0.399±0.102, 0.640±0.051, and 0.579±0.096, respectively. Using predicted masks, the corresponding values were 0.650±0.068, 0.603±0.250, 0.375±0.072, 0.563±0.123, and 0.545±0.071. Scheme B achieved a native nnU-Net mean validation Dice of 0.493±0.044 and region-level AUC, recall, F1-score, accuracy, and case-level accuracy of 0.730±0.024, 0.445±0.051, 0.510±0.045, 0.808±0.015, and 0.738±0.058, respectively. Voxel-level segmentation and clinically oriented grading performance were not directly aligned. Scheme A provided stable anatomical segmentation but more variable downstream grading, whereas scheme B achieved better overall region- and case-level classification performance but lower severe-degeneration recall. Both spatial and clinical decision metrics should therefore be considered when evaluating automated facet joint grading systems.
SN  - 2223-4292
SN  - 2223-4306
ER  -