Large Language Model‐Based Localization of Premature Ventricular Contraction Origins: A Retrospective Diagnostic Accuracy Study
- 1Department of Cardiology Saitama Medical University, International Medical Center Hidaka Saitama Japan
- 2Sera, Inc Meguro Tokyo Japan
- 3Department of Clinical Engineer Saitama Medical University International Medical Center Hidaka Saitama Japan
Abstract
Background: Accurate localization of premature ventricular contraction (PVC) origin from 12‐lead electrocardiography (ECG) is important for procedural planning in catheter ablation. Although convolutional neural network (CNN)‐based models have shown promising diagnostic performance, they require task‐specific training and remain limited in interpretability. We evaluated whether large language model (LLM)‐based ECG image interpretation could perform binary left‐versus‐right PVC origin localization from 12‐lead ECG images while providing a traceable diagnostic process.
Methods: We retrospectively studied 157 patients who underwent successful catheter ablation of PVCs or idiopathic ventricular tachycardia. ECG images were classified as RIGHT‐origin (n = 103) or LEFT‐origin (n = 54) according to the final successful ablation site. Three approaches were compared: a CNN‐based baseline model, an LLM‐based one‐shot approach, and an LLM‐based staged extraction framework with deterministic rule‐based integration. Performance was evaluated across five independent seeds using positive predictive value (PPV), negative predictive value (NPV), recall, and PPV + NPV.
Results: The CNN‐based baseline model achieved a PPV of 0.546 ± 0.058 and an NPV of 0.793 ± 0.047, with area under the curve values ranging from 0.595 to 0.730. The staged extraction framework generated a continuous rule‐based score with discrimination numerically comparable to the CNN‐based model (AUC 0.720 ± 0.045 vs. 0.712 ± 0.054). A stricter threshold, determined from training data, increased PPV at the expense of recall and warrants prospective external validation of this operating point.
Conclusions: LLM‐based staged extraction demonstrated the potential to achieve binary left‐versus‐right PVC origin localization from 12‐lead ECG images while providing a traceable stepwise diagnostic process. The continuous rule‐based score showed discrimination numerically comparable to the CNN‐based model, and the strict threshold—determined using training data—identified a potential high‐PPV operating point that requires prospective external validation.
Related
- GCTRNet: global context-gated temporal refinement for short-window ECG-based premature ventricular contraction detection.
- An Interpretable DSP Architecture for ECG Rhythm and Premature Ventricular Contraction Detection in MATLAB/Simulink
- Catheter ablation of premature ventricular complexes originating from the proximal left anterior fascicle: from electrocardiographic localization to strategy optimization
- Analysis of activation recovery interval at the Purkinje fiber-myocardial junction in ventricular fibrillation storm triggered by premature ventricular contractions: A case report.
- Transcatheter suture embolization for ventricular premature beats originating from the distal great cardiac vein: A case report.
BibTeX
@article{matsumoto2026large,
title = {{Large Language Model‐Based Localization of Premature Ventricular Contraction Origins: A Retrospective Diagnostic Accuracy Study}},
author = {Kazuhisa Matsumoto and Yuya Fujisaki and Syunta Higuchi and Masataka Narita and Wataru Sasaki and Tsukasa Naganuma and Naomichi Tanaka and Daisuke Kawano and Kei Matsumoto and Wataru Yoshino and Yoshifumi Ikeda and Ritsushi Kato and Hitoshi Mori},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
month = aug,
doi = {10.1111/jce.70464},
url = {https://doi.org/10.1111/jce.70464},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Large Language Model‐Based Localization of Premature Ventricular Contraction Origins: A Retrospective Diagnostic Accuracy Study
AU - Kazuhisa Matsumoto
AU - Yuya Fujisaki
AU - Syunta Higuchi
AU - Masataka Narita
AU - Wataru Sasaki
AU - Tsukasa Naganuma
AU - Naomichi Tanaka
AU - Daisuke Kawano
AU - Kei Matsumoto
AU - Wataru Yoshino
AU - Yoshifumi Ikeda
AU - Ritsushi Kato
AU - Hitoshi Mori
PY - 2026
DA - 2026/08/01
JO - Journal of Cardiovascular Electrophysiology
DO - 10.1111/jce.70464
UR - https://doi.org/10.1111/jce.70464
AB - Background: Accurate localization of premature ventricular contraction (PVC) origin from 12‐lead electrocardiography (ECG) is important for procedural planning in catheter ablation. Although convolutional neural network (CNN)‐based models have shown promising diagnostic performance, they require task‐specific training and remain limited in interpretability. We evaluated whether large language model (LLM)‐based ECG image interpretation could perform binary left‐versus‐right PVC origin localization from 12‐lead ECG images while providing a traceable diagnostic process. Methods: We retrospectively studied 157 patients who underwent successful catheter ablation of PVCs or idiopathic ventricular tachycardia. ECG images were classified as RIGHT‐origin (n = 103) or LEFT‐origin (n = 54) according to the final successful ablation site. Three approaches were compared: a CNN‐based baseline model, an LLM‐based one‐shot approach, and an LLM‐based staged extraction framework with deterministic rule‐based integration. Performance was evaluated across five independent seeds using positive predictive value (PPV), negative predictive value (NPV), recall, and PPV + NPV. Results: The CNN‐based baseline model achieved a PPV of 0.546 ± 0.058 and an NPV of 0.793 ± 0.047, with area under the curve values ranging from 0.595 to 0.730. The staged extraction framework generated a continuous rule‐based score with discrimination numerically comparable to the CNN‐based model (AUC 0.720 ± 0.045 vs. 0.712 ± 0.054). A stricter threshold, determined from training data, increased PPV at the expense of recall and warrants prospective external validation of this operating point. Conclusions: LLM‐based staged extraction demonstrated the potential to achieve binary left‐versus‐right PVC origin localization from 12‐lead ECG images while providing a traceable stepwise diagnostic process. The continuous rule‐based score showed discrimination numerically comparable to the CNN‐based model, and the strict threshold—determined using training data—identified a potential high‐PPV operating point that requires prospective external validation.
SN - 1045-3873
SN - 1540-8167
ER -