Temporal Pattern of Central Venous Catheter Tip Position Change on Serial Chest Radiographs in Non-ICU Adults: A Retrospective Observational Study
7 affiliations
- 1Department of Anesthesiology and Reanimation, Faculty of Medicine, Bezmialem Vakıf University, 34093 Istanbul, Türkiye
- 2Department of Pulmonology (Chest Diseases), Faculty of Medicine, Bezmialem Vakıf University, 34093 Istanbul, Türkiye
- 3Department of Cardiology, Faculty of Medicine, Bezmialem Vakıf University, 34093 Istanbul, Türkiye
- 4Department of Cardiology, Faculty of Medicine, Ahi Evran University, 40100 Kirsehir, Türkiye
- 5Department of Anesthesiology and Reanimation, Büyükçekmece Mimar Sinan State Hospital, Republic of Türkiye Ministry of Health, 34535 Istanbul, Türkiye
- 6Department of Anesthesiology and Reanimation, Bozova Mehmet-Enver Yıldırım State Hospital, Republic of Türkiye Ministry of Health, 63850 Sanliurfa, Türkiye
- 7Department of Anesthesiology and Reanimation, School of Medicine, Istanbul Atlas University, 34408 Istanbul, Türkiye
Abstract
Background/Objectives: Central venous catheter (CVC) tips may change position after insertion, but the time course of this change outside the intensive care unit (ICU) is poorly described. We quantified carina-referenced CVC tip position change across consecutive follow-up radiographs in non-ICU adults. Methods: This single-center retrospective study included 109 adults with a non-tunneled CVC inserted in the operating room and followed on non-ICU wards who had an immediate post-insertion radiograph (T0) and three follow-up radiographs (T1–T3). The carina-to-tip distance was measured on each radiograph, and displacement between consecutive radiographs was analyzed with patient-clustered generalized estimating equations adjusted for age, sex, body mass index, insertion site, and baseline tip position. Displacement of ≥10 mm was the prespecified threshold. Results: Follow-up radiographs were obtained at median days 5, 9, and 16. Adjusted displacement during T2–T3 was lower than during T0–T1 (mean difference −3.21 mm, 95% confidence interval [CI] −5.47 to −0.95; p = 0.005). Displacement of ≥10 mm occurred in 46.8%, 33.9%, and 19.3% of patients (T2–T3 vs. T0–T1: odds ratio 0.27, 95% CI 0.15–0.49; p < 0.001), and the decrease persisted after adjustment for interval duration. No direction of movement predominated, and no demographic or insertion-site variable was significantly associated with displacement. Conclusions: Carina-referenced CVC tip position changed most during early follow-up and less thereafter, but displacement of ≥10 mm was still recorded in about one in five patients during the last interval. Tip position should not be regarded as fixed after the initial radiograph. Because clinical outcomes were not assessed, these findings do not by themselves support changes to imaging surveillance practice.
Related
- Initial peripherally inserted central catheter tip position accuracy by puncture arm and associated factors in female patients with breast cancer: A retrospective cohort study
- Reassurance or Redundancy: A Retrospective Observational Study of the Clinical Utility of Abdominal Radiographs in an Australian Emergency Department
- Evaluation of the Position of Impacted Maxillary Canines on Panoramic Radiographs Using Deep Learning with CBCT as the Reference Standard
- Patient- and Operator-Related Factors Associated With Difficult Lumbar Epidural Catheter Placement: A Retrospective Observational Study
- Prone position ventilation for pediatric acute respiratory distress syndrome with ECMO: a retrospective observational study in China
BibTeX
@article{sari2026temporal,
title = {{Temporal Pattern of Central Venous Catheter Tip Position Change on Serial Chest Radiographs in Non-ICU Adults: A Retrospective Observational Study}},
author = {Mehmet Sari and Hamza Ogun and Aydin Nadir and Muhammet Salih Ates and Monira Turkmen and Ali Sevgili and Ergun Gunduz},
journal = {Journal of Clinical Medicine},
year = {2026},
month = nov,
doi = {10.3390/jcm15239174},
url = {https://www.mdpi.com/2077-0383/15/23/9174},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Temporal Pattern of Central Venous Catheter Tip Position Change on Serial Chest Radiographs in Non-ICU Adults: A Retrospective Observational Study
AU - Mehmet Sari
AU - Hamza Ogun
AU - Aydin Nadir
AU - Muhammet Salih Ates
AU - Monira Turkmen
AU - Ali Sevgili
AU - Ergun Gunduz
PY - 2026
DA - 2026/11/23
JO - Journal of Clinical Medicine
DO - 10.3390/jcm15239174
UR - https://www.mdpi.com/2077-0383/15/23/9174
AB - Background/Objectives: Central venous catheter (CVC) tips may change position after insertion, but the time course of this change outside the intensive care unit (ICU) is poorly described. We quantified carina-referenced CVC tip position change across consecutive follow-up radiographs in non-ICU adults. Methods: This single-center retrospective study included 109 adults with a non-tunneled CVC inserted in the operating room and followed on non-ICU wards who had an immediate post-insertion radiograph (T0) and three follow-up radiographs (T1–T3). The carina-to-tip distance was measured on each radiograph, and displacement between consecutive radiographs was analyzed with patient-clustered generalized estimating equations adjusted for age, sex, body mass index, insertion site, and baseline tip position. Displacement of ≥10 mm was the prespecified threshold. Results: Follow-up radiographs were obtained at median days 5, 9, and 16. Adjusted displacement during T2–T3 was lower than during T0–T1 (mean difference −3.21 mm, 95% confidence interval [CI] −5.47 to −0.95; p = 0.005). Displacement of ≥10 mm occurred in 46.8%, 33.9%, and 19.3% of patients (T2–T3 vs. T0–T1: odds ratio 0.27, 95% CI 0.15–0.49; p < 0.001), and the decrease persisted after adjustment for interval duration. No direction of movement predominated, and no demographic or insertion-site variable was significantly associated with displacement. Conclusions: Carina-referenced CVC tip position changed most during early follow-up and less thereafter, but displacement of ≥10 mm was still recorded in about one in five patients during the last interval. Tip position should not be regarded as fixed after the initial radiograph. Because clinical outcomes were not assessed, these findings do not by themselves support changes to imaging surveillance practice.
SN - 2077-0383
ER -