Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 39 min ago
Peer-reviewedCC BY-NC-NDStructural Heart

Pooled Periprocedural and Short-Term Outcomes After Transcatheter Aortic Valve Replacement With Contemporary Self-Expanding Valves: A Systematic Review and Meta-Analysis

3 more authors
8 affiliations
  1. 1Department of Medicine, SRTR Government Medical College, Ambajogai, Maharashtra, India
  2. 2Department of Medicine, KAP Viswanatham Government Medical College, Tiruchirappalli, Tamilnadu, India
  3. 3Department of Medicine, Guangxi Medical University, Nanning, China
  4. 4Department of Cardiology, Houston Methodist DeBakey Heart and Vascular Center, Houston, Texas, USA
  5. 5Section of Cardiology, Baylor College of Medicine, Michael E DeBakey Veterans Affairs Medical Center, Houston, Texas, USA
  6. 6Department of Medicine, Baylor College of Medicine, Houston, Texas, USA
  7. 7Department of Cardiovascular Surgery, Houston Methodist Hospital, Houston, Texas, USA
  8. 8Department of Medicine, Baylor College of Medicine, Houston, Texas, USA; Address correspondence to: Sahar Samimi, MD, Department of Medicine, Baylor College of Medicine, Houston, TX.

Abstract

Background: Contemporary self-expanding transcatheter heart valves (SEVs) have incorporated design refinements to reduce paravalvular leak (PVL) and pacemaker implantation (PPI). We aimed to characterize clinical outcomes after transcatheter aortic valve replacement (TAVR) with contemporary SEVs in patients with severe aortic stenosis. Methods: PubMed, EMBASE, and Scopus were searched through October 5, 2025, for studies reporting procedural, hemodynamic, and clinical outcomes for patients undergoing TAVR with the (1) Navitor or (2) Evolut PRO/PRO+/FX. Random-effects meta-analyses pooled single-arm event rates, stratified by SEV group, using the Freeman–Tukey double arcsine transformation. Between-platform differences were assessed using subgroup interaction testing. Results: Fifty-two studies (n = 21,349; weighted mean age 82 years; mean Society of Thoracic Surgeons Predicted Risk of Mortality 4.8%) were included. At 30 days, all-cause mortality was low among Evolut and Navitor cohorts (1.4 and 1.5%; p = 0.63), and device success was high for both platforms (92.1 and 93.0%; p = 0.73). Moderate or greater PVL occurred in 2.5 and 1.1% of Evolut and Navitor cohorts, respectively ( p = 0.12), mild PVL occurred in 31.1 and 19.9% ( p = 0.046), and new PPI occurred in 13.4 and 15.3%, respectively. Mean gradients remained low among Evolut and Navitor cohorts at 1 year (7.7 and 7.3 mmHg; p = 0.65), whereas effective orifice area was higher among Evolut cohorts at 1 year (2.1 and 1.8 cm 2 ; p < 0.001) ( p = p -interaction). Conclusions: Navitor and Evolut PRO/PRO+/FX both demonstrated high device success, low mortality, favorable hemodynamic performance, and low rates of moderate or greater PVL at 1-year follow-up. Mild PVL and new PPI remained frequent. Observed comparative signals should be interpreted as indirect hypothesis-generating findings.

Related

  1. Surgical aortic valve replacement-level aortotomy for self-expanding transcatheter aortic valve explantation
    Israa Saleh, Raymond L. Benza, Deepak R. Talreja +3
    JTCVS techniquesPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Institutional Volume Thresholds and Risk‐Adjusted Outcomes After Transcatheter Aortic Valve Replacement: Contemporary Evidence From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry
    Sant Kumar, Ashish Pershad, Hursh Naik +1
    Journal of the American Heart Association: Cardiovascular and Cerebrovascular DiseasePeer-reviewedCC BY-NC-ND 4.0Full text1 citedCardiovascular medicinePMC
  3. Stroke After Transcatheter Aortic Valve Replacement With Contemporary Valves: Insights From the OCEAN-TAVI Registry
    Yusuke Watanabe, MD, Masanori Yamamoto, MD, Hirofumi Hioki, MD +29
    Structural HeartPeer-reviewedCC BYFull textCardiovascular medicineDOAJEurope PMCPMC
  4. Prognostic value of algorithm-based invasive haemodynamic assessment of paravalvular regurgitation after transcatheter aortic valve replacement with self-expanding devices-the APPOSE registry.
    Niels A Stens, Geert A A Versteeg, Maxim J P Rooijakkers +16
    European heart journal. Valvular and structural heart diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMCPMC
  5. Clinical Outcomes of Transcatheter Versus Surgical Aortic Valve Replacement in Patients with Pure Native Aortic Regurgitation: A Systematic Review and Meta-Analysis
    Honghong Ke, Shirong Wang, Jinyi Li +1
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
BibTeX
@article{shawnshaji2026pooled,
  title = {{Pooled Periprocedural and Short-Term Outcomes After Transcatheter Aortic Valve Replacement With Contemporary Self-Expanding Valves: A Systematic Review and Meta-Analysis}},
  author = {Shawn Shaji, MBBS and Praveen Bharath Saravanan, MBBS and Rahul Sarkar, MBBS and Chloe Kharsa, MD and Joe Aoun, MD and Syed Zaid, MD and Waleed T. Kayani, MD and Nadeen Faza, MD, FACC and Stephen H. Little, MD, FACC and Marvin Atkins, MD and Fernando Ramirez Del Val, MD and Neal S. Kleiman, MD, FACC and Michael J. Reardon, MD, FACS and Sahar Samimi, MD and Sachin S. Goel, MD, FACC},
  journal = {Structural Heart},
  year = {2026},
  month = aug,
  doi = {10.1016/j.shj.2026.101106},
  url = {https://doi.org/10.1016/j.shj.2026.101106},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Pooled Periprocedural and Short-Term Outcomes After Transcatheter Aortic Valve Replacement With Contemporary Self-Expanding Valves: A Systematic Review and Meta-Analysis
AU  - Shawn Shaji, MBBS
AU  - Praveen Bharath Saravanan, MBBS
AU  - Rahul Sarkar, MBBS
AU  - Chloe Kharsa, MD
AU  - Joe Aoun, MD
AU  - Syed Zaid, MD
AU  - Waleed T. Kayani, MD
AU  - Nadeen Faza, MD, FACC
AU  - Stephen H. Little, MD, FACC
AU  - Marvin Atkins, MD
AU  - Fernando Ramirez Del Val, MD
AU  - Neal S. Kleiman, MD, FACC
AU  - Michael J. Reardon, MD, FACS
AU  - Sahar Samimi, MD
AU  - Sachin S. Goel, MD, FACC
PY  - 2026
DA  - 2026/08/07
JO  - Structural Heart
DO  - 10.1016/j.shj.2026.101106
UR  - https://doi.org/10.1016/j.shj.2026.101106
AB  - Background: Contemporary self-expanding transcatheter heart valves (SEVs) have incorporated design refinements to reduce paravalvular leak (PVL) and pacemaker implantation (PPI). We aimed to characterize clinical outcomes after transcatheter aortic valve replacement (TAVR) with contemporary SEVs in patients with severe aortic stenosis. Methods: PubMed, EMBASE, and Scopus were searched through October 5, 2025, for studies reporting procedural, hemodynamic, and clinical outcomes for patients undergoing TAVR with the (1) Navitor or (2) Evolut PRO/PRO+/FX. Random-effects meta-analyses pooled single-arm event rates, stratified by SEV group, using the Freeman–Tukey double arcsine transformation. Between-platform differences were assessed using subgroup interaction testing. Results: Fifty-two studies (n = 21,349; weighted mean age 82 years; mean Society of Thoracic Surgeons Predicted Risk of Mortality 4.8%) were included. At 30 days, all-cause mortality was low among Evolut and Navitor cohorts (1.4 and 1.5%; p = 0.63), and device success was high for both platforms (92.1 and 93.0%; p = 0.73). Moderate or greater PVL occurred in 2.5 and 1.1% of Evolut and Navitor cohorts, respectively ( p = 0.12), mild PVL occurred in 31.1 and 19.9% ( p = 0.046), and new PPI occurred in 13.4 and 15.3%, respectively. Mean gradients remained low among Evolut and Navitor cohorts at 1 year (7.7 and 7.3 mmHg; p = 0.65), whereas effective orifice area was higher among Evolut cohorts at 1 year (2.1 and 1.8 cm 2 ; p < 0.001) ( p = p -interaction). Conclusions: Navitor and Evolut PRO/PRO+/FX both demonstrated high device success, low mortality, favorable hemodynamic performance, and low rates of moderate or greater PVL at 1-year follow-up. Mild PVL and new PPI remained frequent. Observed comparative signals should be interpreted as indirect hypothesis-generating findings.
SN  - 2474-8706
SN  - 2474-8714
ER  -