Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 3 min ago
PreprintCC BYbioRxiv

Wearable Estimation of Knee Joint Contact Forces: SiMPLeSENSE, a Simulated-IMU Pipeline Validated Against In Vivo Loads

  1. 1University of Twente

Abstract

Knee joint compressive forces (KCF) are central to understanding joint loading and degeneration, but they can be measured directly only with instrumented implants. Musculoskeletal models provide a non-invasive alternative, and inertial measurement units (IMUs) could make such estimates portable. However, no dataset combines IMU signals with in vivo implant forces, so the accuracy of IMU-based KCF remains unverified. We developed SiMPLeSENSE, a framework that derives virtual IMU orientations from optical motion capture using subject-specific SMPL meshes. Using the CAMS-Knee dataset, we reconstructed kinematics with OpenSense and estimated KCF in OpenSim with a Rapid Muscle Redundancy solver, comparing the estimates with in vivo measurements during level walking and stair descent. We also assessed robustness to sensor placement error by adding empirically derived thigh and shank orientation noise (for two cases). Across subjects and activities, the simulated-IMU estimates closely tracked the optical mocap-driven estimates and reproduced the in vivo force pattern, with the agreement against the optical reference being higher for stair descent. Overall, the estimated forces matched the in vivo measurements with a median RMSE of about 0.3 to 0.5 BW and correlations near 0.95. Adding realistic orientation error increased RMSE only modestly, whereas doubling it markedly overestimated peak force, most evident for stair descent. These results indicate that the approach is robust to substantial changes in input kinematics, supporting a laboratory-independent setup combining inertial motion capture, a small EMG set, and instrumented force shoes for home and clinical monitoring of knee loading.

Related

  1. Poly Pipeline: A Polyvalent Spatial Transcriptomics Workflow Validated Across Polyploid and Diploid Organisms
    P. C. Carvalho, T. Millsteed, R. J. Henry
    bioRxivPreprintCC BYFull textBioinformatics & computational biologybioRxiv
  2. An auditable agentic pipeline for variant-to-gene prioritisation, validated against orthogonal functional evidence
    Shakuntala Baichoo, Sohail, Sarkar +1
    arXivPreprintCC BY 4.0Full textGenetics & genomicsarXiv
  3. A multi‐race blast resistance locus identified and validated in US elite rice via association and biparental mapping
    J. M. Manangkil, B. Angira, E. Oliveira‐Garcia +7
    The plant genomePeer-reviewedCC BY-NC-NDFull textGenetics & genomicsPlant biologyEurope PMC
  4. Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors
    L. I. Almofeez, M. S. Islam, T. S. Ambagahawaththa +1
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  5. Frequency modulated semi-continuous wave Doppler ultrasound: A novel method for the detection of scatterer velocity and range using wearable ultrasound instrumentation
    C. M. Delaney, A. Bashatah, A. Aher +4
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
BibTeX
@misc{castellaz2026wearable,
  title = {{Wearable Estimation of Knee Joint Contact Forces: SiMPLeSENSE, a Simulated-IMU Pipeline Validated Against In Vivo Loads}},
  author = {A. Castellaz and S. Hörmann and A. Seth and B.-J. v. Beijnum and F. Wouda},
  howpublished = {bioRxiv},
  year = {2026},
  month = nov,
  doi = {10.64898/2026.11.03.763565},
  url = {https://www.biorxiv.org/content/10.64898/2026.11.03.763565v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Wearable Estimation of Knee Joint Contact Forces: SiMPLeSENSE, a Simulated-IMU Pipeline Validated Against In Vivo Loads
AU  - A. Castellaz
AU  - S. Hörmann
AU  - A. Seth
AU  - B.-J. v. Beijnum
AU  - F. Wouda
PY  - 2026
DA  - 2026/11/03
PB  - bioRxiv
DO  - 10.64898/2026.11.03.763565
UR  - https://www.biorxiv.org/content/10.64898/2026.11.03.763565v1
AB  - Knee joint compressive forces (KCF) are central to understanding joint loading and degeneration, but they can be measured directly only with instrumented implants. Musculoskeletal models provide a non-invasive alternative, and inertial measurement units (IMUs) could make such estimates portable. However, no dataset combines IMU signals with in vivo implant forces, so the accuracy of IMU-based KCF remains unverified. We developed SiMPLeSENSE, a framework that derives virtual IMU orientations from optical motion capture using subject-specific SMPL meshes. Using the CAMS-Knee dataset, we reconstructed kinematics with OpenSense and estimated KCF in OpenSim with a Rapid Muscle Redundancy solver, comparing the estimates with in vivo measurements during level walking and stair descent. We also assessed robustness to sensor placement error by adding empirically derived thigh and shank orientation noise (for two cases). Across subjects and activities, the simulated-IMU estimates closely tracked the optical mocap-driven estimates and reproduced the in vivo force pattern, with the agreement against the optical reference being higher for stair descent. Overall, the estimated forces matched the in vivo measurements with a median RMSE of about 0.3 to 0.5 BW and correlations near 0.95. Adding realistic orientation error increased RMSE only modestly, whereas doubling it markedly overestimated peak force, most evident for stair descent. These results indicate that the approach is robust to substantial changes in input kinematics, supporting a laboratory-independent setup combining inertial motion capture, a small EMG set, and instrumented force shoes for home and clinical monitoring of knee loading.
ER  -