Investigation of YSO-SiPM detector response for alpha spectroscopy applications.
6 affiliations
- 1Nuclear Research Department, Innovation and Digital Development Agency, Abşeron, AZ1069, Azerbaijan.
- 2Azerbaijan University of Architecture and Construction, Baku, AZ1073, Azerbaijan.
- 3Innovative Electronics and Detectors LLC, Baku, AZ1021, Azerbaijan.
- 4Institute of Physics - Ministry of Science and Education, Baku, AZ1073, Azerbaijan.
- 5Khazar University, Baku, AZ1096, Azerbaijan.
- 6The Institute of Nuclear Physics, Almaty, 050032, Kazakhstan.
Abstract
Background
Alpha-particle spectroscopy is widely used in nuclear physics, radiation monitoring, safeguards, and environmental measurements. Conventional silicon detectors provide excellent spectrometric performance; however, their application in portable or harsh-environment instrumentation may be limited by mechanical fragility, radiation sensitivity, and operational constraints. Scintillator-based detectors coupled to silicon photomultipliers (SiPMs) represent a promising alternative because of their compactness, robustness, and simplified integration with modern electronics. Despite the favorable scintillation properties of yttrium orthosilicate (YSO), its applicability for alpha-particle spectroscopy has received limited investigation.Methods
The response of a YSO scintillator coupled to a Hamamatsu S13360-3050 multi-pixel photon counter (MPPC) array was investigated using alpha particles emitted from a ²³⁸Pu source. A 10 × 10 × 10 mm ³ YSO crystal was coupled to the SiPM array and read out using CAEN digitization electronics. Alpha-particle energies in the approximate range from 0.4 MeV to 5.5 MeV were obtained by varying the air-layer thickness between the radioactive source and detector. Signal acquisition was performed using a CAEN DT5720 digitizer operated in self-trigger mode, while offline waveform processing was performed using ROOT-based software.Results
The YSO-SiPM detector exhibited stable and approximately linear response characteristics across the investigated energy interval. The measured deviation from linearity was approximately 3%. The experimentally determined alpha-particle flight distance in air was measured as 40.58 ± 0.87 mm, in good agreement with SRIM simulations predicting approximately 42 mm. The measured energy resolution varied from approximately 10.5% at 5.5 MeV to approximately 21% at lower alpha-particle energies near 0.4 MeV. Alpha-particle signals remained clearly distinguishable down to approximately 500 keV.Conclusions
The obtained results demonstrate that the YSO-SiPM configuration represents a compact and mechanically robust detector solution for alpha-particle spectroscopy. Although the energy resolution remains inferior to conventional silicon alpha detectors, the investigated system offers important practical advantages including operation under ambient conditions, simplified electronics integration, scalability, and suitability for portable or harsh-environment nuclear instrumentation.
Related
- Detailed investigation on the Geant4 simulation of alpha particles in liquid scintillator detector
- The MIRI/MRS Library. III. Detector-based optimal spectral extraction and high-contrast imaging applications
- A Large-Volume GAGG(Ce) Detector Module for In-Beam γ-Ray Spectroscopy
- Investigation of the Enantioselectivity of three Polypeptide Liquid Crystal Solvents Using NMR Spectroscopy
- Reevaluating Gold(I) Thiophilicity in Reduced Dielectric Environments: IRMPD Spectroscopy and Theoretical Investigation of Auranofin-Glutathione Complexes.
BibTeX
@article{ahmadov2026investigation,
title = {{Investigation of YSO-SiPM detector response for alpha spectroscopy applications.}},
author = {Gadir Ahmadov and Sebuhi Nuruyev and Daniyar Berikov and Arzu Mammadli and Azer Sadygov and Alisher Temirzhanov and Kairat Mendibayev and Murad Kenessarin and Ramil Akbarov and Farid Ahmadov},
journal = {Open research Europe},
year = {2026},
month = sep,
doi = {10.12688/openreseurope.24095.1},
url = {https://europepmc.org/article/MED/42859429},
note = {CC BY},
}
RIS
TY - JOUR
TI - Investigation of YSO-SiPM detector response for alpha spectroscopy applications.
AU - Gadir Ahmadov
AU - Sebuhi Nuruyev
AU - Daniyar Berikov
AU - Arzu Mammadli
AU - Azer Sadygov
AU - Alisher Temirzhanov
AU - Kairat Mendibayev
AU - Murad Kenessarin
AU - Ramil Akbarov
AU - Farid Ahmadov
PY - 2026
DA - 2026/09/18
JO - Open research Europe
DO - 10.12688/openreseurope.24095.1
UR - https://europepmc.org/article/MED/42859429
AB - Background Alpha-particle spectroscopy is widely used in nuclear physics, radiation monitoring, safeguards, and environmental measurements. Conventional silicon detectors provide excellent spectrometric performance; however, their application in portable or harsh-environment instrumentation may be limited by mechanical fragility, radiation sensitivity, and operational constraints. Scintillator-based detectors coupled to silicon photomultipliers (SiPMs) represent a promising alternative because of their compactness, robustness, and simplified integration with modern electronics. Despite the favorable scintillation properties of yttrium orthosilicate (YSO), its applicability for alpha-particle spectroscopy has received limited investigation.Methods The response of a YSO scintillator coupled to a Hamamatsu S13360-3050 multi-pixel photon counter (MPPC) array was investigated using alpha particles emitted from a ²³⁸Pu source. A 10 × 10 × 10 mm ³ YSO crystal was coupled to the SiPM array and read out using CAEN digitization electronics. Alpha-particle energies in the approximate range from 0.4 MeV to 5.5 MeV were obtained by varying the air-layer thickness between the radioactive source and detector. Signal acquisition was performed using a CAEN DT5720 digitizer operated in self-trigger mode, while offline waveform processing was performed using ROOT-based software.Results The YSO-SiPM detector exhibited stable and approximately linear response characteristics across the investigated energy interval. The measured deviation from linearity was approximately 3%. The experimentally determined alpha-particle flight distance in air was measured as 40.58 ± 0.87 mm, in good agreement with SRIM simulations predicting approximately 42 mm. The measured energy resolution varied from approximately 10.5% at 5.5 MeV to approximately 21% at lower alpha-particle energies near 0.4 MeV. Alpha-particle signals remained clearly distinguishable down to approximately 500 keV.Conclusions The obtained results demonstrate that the YSO-SiPM configuration represents a compact and mechanically robust detector solution for alpha-particle spectroscopy. Although the energy resolution remains inferior to conventional silicon alpha detectors, the investigated system offers important practical advantages including operation under ambient conditions, simplified electronics integration, scalability, and suitability for portable or harsh-environment nuclear instrumentation.
SN - 2732-5121
ER -