Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BY 4.0Cardiovascular Engineering and Technology

Reduction of Motion Artifacts in Cardiorespiratory Vital Signs as Oxygen Saturation and Non-Invasive Blood Pressure Through Redundant Denoising and Adaptive Filtering Methods for Wearable Healthcare Monitoring Systems

  1. 1Bioinstrumentation and Clinical Engineering Research Group - GIBIC, Bioengineering Department, Engineering Faculty, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, 050010 Colombia
  2. 2Physics Institute,Exact and Natural Sciences Faculty, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín, 050010 Colombia

Abstract

Background and objective: Chronic cardiovascular diseases have motivated the development of wearable systems capable of continuously monitoring physiological variables such as oxygen saturation (SpO\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}2\end{document}2) and non-invasive blood pressure (NIBP). However, motion artifacts remain one of the main limitations affecting the reliability of these measurements in ambulatory environments. This article presents a novel framework for motion artifact reduction in photoplethysmography (PPG) and NIBP signals based on redundant sensing, inertial measurements, ECG-guided temporal synchrony, and multichannel signal processing.

Methods: The proposed framework combines independent component analysis and recursive least-squares adaptive filtering to separate physiological information from motion-induced interference. Performance was compared with conventional finite impulse response (FIR) filtering and wavelet shrinkage (WS) methods using signal-to-noise ratio (SNR), weighted distortion assessment (WDA), oxygen saturation estimation, and blood pressure estimation metrics.

Results: The proposed method achieved statistically significant improvements in signal quality and physiological parameter estimation. Average SNR improved from -5.93± 5.05-5.93±5.05 dB to -3.43± 2.02-3.43±2.02 dB in the red PPG channel (p=0.02p=0.02), while the WDA index increased from 0.48 to 0.73. Oxygen saturation estimation improved from \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}80.87± 9.09%\end{document}80.87±9.09% in motion-contaminated signals to \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}94.16± 2.72%\end{document}94.16±2.72% after denoising (p=0.04p=0.04), approaching resting measurements (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}95.23± 2.31%\end{document}95.23±2.31%). For NIBP signals, statistically significant improvements were also observed (p=0.045p=0.045), particularly for systolic pressure estimation, although diastolic pressure remained affected by residual motion-related distortions.

Conclusions: The proposed framework improves the robustness of wearable PPG and NIBP monitoring under motion conditions through the combined use of sensor redundancy, ECG-guided temporal coupling, inertial measurements, and adaptive multichannel signal processing. The results demonstrate significant improvements in signal quality and physiological parameter estimation compared with conventional denoising approaches, supporting the potential use of the method in ambulatory cardiovascular monitoring applications.

Related

  1. Prognostic prediction model construction and validation based on regional cerebral oxygen saturation and bispectral index monitoring in pediatric traumatic brain injury
    Baowen Li, Ruhai Ma, Zhuyun Tian +5
    Frontiers in NeurosciencePeer-reviewedCC BY 4.0Full textNeurologyCrossrefEurope PMCPMC
  2. Impact of Artificial Intelligence on Operational Efficiency and Cost Reduction in U.S. Healthcare Organizations
    Jahanara Akther
    American Journal of Interdisciplinary StudiesPeer-reviewedLicence not statedFull text26 citedEpidemiology & public healthOpenAlex
  3. Knowledge, attitude and practice on continuous glucose monitoring and self-monitoring of blood glucose among healthcare professionals across India: A cross-sectional study
    Nitin Kapoor, Shehla Sheikh, Sambit Das +3
    TouchREVIEWS in endocrinologyPeer-reviewedCC BYFull textEndocrinology & metabolismEurope PMCPMC
  4. Patient and healthcare professional preferences among predefined features of a peritoneal dialysis monitoring application in South Korea: an exploratory choice-based conjoint study
    KyungYi Kim, Taeyeon Kim, Sang Gyu Lee +2
    Scientific ReportsPeer-reviewedCC BY 4.0Full textGeneral medicineCrossref
  5. Growth Monitoring and Promotion Practice and Associated Factors Among Healthcare Workers in Public Health Facilities of Central Zone of Tigray, Ethiopia, 2023/2024: Mixed Study Design
    Gebrehiwet Haile Bezabh, Gebregziabher Kidanemariam Asfaw
    BioMed Research InternationalPeer-reviewedCC BY 4.0Full textObstetrics, gynaecology & paediatricsPMC
BibTeX
@article{castano2026reduction,
  title = {{Reduction of Motion Artifacts in Cardiorespiratory Vital Signs as Oxygen Saturation and Non-Invasive Blood Pressure Through Redundant Denoising and Adaptive Filtering Methods for Wearable Healthcare Monitoring Systems}},
  author = {Fabian Andres Castaño and Alher Mauricio Hernández},
  journal = {Cardiovascular Engineering and Technology},
  year = {2026},
  month = aug,
  doi = {10.1007/s13239-026-00850-0},
  url = {https://doi.org/10.1007/s13239-026-00850-0},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Reduction of Motion Artifacts in Cardiorespiratory Vital Signs as Oxygen Saturation and Non-Invasive Blood Pressure Through Redundant Denoising and Adaptive Filtering Methods for Wearable Healthcare Monitoring Systems
AU  - Fabian Andres Castaño
AU  - Alher Mauricio Hernández
PY  - 2026
DA  - 2026/08/03
JO  - Cardiovascular Engineering and Technology
DO  - 10.1007/s13239-026-00850-0
UR  - https://doi.org/10.1007/s13239-026-00850-0
AB  - Background and objective: Chronic cardiovascular diseases have motivated the development of wearable systems capable of continuously monitoring physiological variables such as oxygen saturation (SpO\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}_2\end{document}2) and non-invasive blood pressure (NIBP). However, motion artifacts remain one of the main limitations affecting the reliability of these measurements in ambulatory environments. This article presents a novel framework for motion artifact reduction in photoplethysmography (PPG) and NIBP signals based on redundant sensing, inertial measurements, ECG-guided temporal synchrony, and multichannel signal processing.  Methods: The proposed framework combines independent component analysis and recursive least-squares adaptive filtering to separate physiological information from motion-induced interference. Performance was compared with conventional finite impulse response (FIR) filtering and wavelet shrinkage (WS) methods using signal-to-noise ratio (SNR), weighted distortion assessment (WDA), oxygen saturation estimation, and blood pressure estimation metrics.  Results: The proposed method achieved statistically significant improvements in signal quality and physiological parameter estimation. Average SNR improved from -5.93± 5.05-5.93±5.05 dB to -3.43± 2.02-3.43±2.02 dB in the red PPG channel (p=0.02p=0.02), while the WDA index increased from 0.48 to 0.73. Oxygen saturation estimation improved from \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}80.87± 9.09%\end{document}80.87±9.09% in motion-contaminated signals to \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}94.16± 2.72%\end{document}94.16±2.72% after denoising (p=0.04p=0.04), approaching resting measurements (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}95.23± 2.31%\end{document}95.23±2.31%). For NIBP signals, statistically significant improvements were also observed (p=0.045p=0.045), particularly for systolic pressure estimation, although diastolic pressure remained affected by residual motion-related distortions.  Conclusions: The proposed framework improves the robustness of wearable PPG and NIBP monitoring under motion conditions through the combined use of sensor redundancy, ECG-guided temporal coupling, inertial measurements, and adaptive multichannel signal processing. The results demonstrate significant improvements in signal quality and physiological parameter estimation compared with conventional denoising approaches, supporting the potential use of the method in ambulatory cardiovascular monitoring applications.
SN  - 1869-408X
SN  - 1869-4098
ER  -