Photonic elastic-backscatter fingerprinting of exhaled-breath metabolites for non-invasive disease screening

Abstract

Optical breath diagnostics normally require molecule-specific spectroscopy. We ask instead how much diagnostic structure survives in the least expensive optical readout available: a single fixed-wavelength diode laser and a dual-axis position-sensing photodiode, giving three channels — back-scattered intensity ( I ) and two beam-position coordinates ( x,y ). Seven calibration classes, comprising five disease-linked breath-metabolite mixtures (disease-linked surrogates) covering established gas concentration ranges (in ppb / ppm), a healthy-air surrogate and an ambient control, were injected at constant mass flow, into a sealed chamber and recorded at 25 kHz, later down sampled to 10 Hz for each run for easing the computational load, over nineteen runs. Detection of any injection is effectively certain within seconds: mean Mahalanobis distances from the ambient cluster are 176 to 447, against a within-cluster mean of 1.6. Concentration is recovered by cubic intensity–concentration calibrations across nine gas channels, with coefficients of determination from 0.966 to 0.997. All seven class centroids separate, and a trajectory-aware nearest-template rule assigns 73.7% of runs correctly on resubstitution. Under leave-one-run-out validation, however, accuracy falls to 52.6% against a chance level of 14.3%, and the beam-deflection channels are shown to be dominated by a common pressure-driven refractive-index gradient rather than by composition - an artefact of the design and architecture of the experiment which can be easily modified to improve accuracy. The three channel readout ( I,x,y ), therefore establishes a validated lower bound for minimal optics, and quantifies precisely what separates that bound from classification-grade breath screening.

Related

  1. Artificial intelligence-based tongue image analysis for non-invasive screening of gastric cancer, precancerous lesions, and related gastrointestinal disorders: a systematic review
    Rukai Wang, Chunlin Li, Hengyan Zhang +3
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Non‐Invasive Intracranial Pressure Waveform Assessment as a Screening Test for Abnormal Lumbar Puncture Results
    Gabriel Taricani Kubota, Alessandra Santos da Fonseca, Cintya Yukie Hayashi +9
    European journal of neurologyPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  3. Routine contrast-enhanced CT screening identifies asymptomatic pulmonary embolism after minimally invasive esophagectomy: incidence and associated factors
    Akira Saito, Tomotake Ariyoshi, Satoru Goto +6
    EsophagusPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  4. Pharmacological Fingerprinting of Cholesterol Biosynthesis Defects
    Matija Fenrich, Ivan Šimunović, Marta Balog +1
    BiomedicinesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Decoding Dementia from Sweat: A Proof-of-Concept Label-Free Raman Fingerprinting of EVs
    A. Ud Din, S. Sharma, M. Mannerkorpi +4
    medRxivPreprintAll rights reservedFull textNeurologymedRxiv
BibTeX
@article{tatavarti2026photonic,
  title = {{Photonic elastic-backscatter fingerprinting of exhaled-breath metabolites for non-invasive disease screening}},
  author = {Rao Tatavarti and Sridevi Nadimpalli and Arulmozhivarman Pachiyappan},
  journal = {Scientific Reports},
  year = {2026},
  month = nov,
  doi = {10.1038/s41598-026-79215-5},
  url = {https://www.nature.com/articles/s41598-026-79215-5},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Photonic elastic-backscatter fingerprinting of exhaled-breath metabolites for non-invasive disease screening
AU  - Rao Tatavarti
AU  - Sridevi Nadimpalli
AU  - Arulmozhivarman Pachiyappan
PY  - 2026
DA  - 2026/11/06
JO  - Scientific Reports
DO  - 10.1038/s41598-026-79215-5
UR  - https://www.nature.com/articles/s41598-026-79215-5
AB  - Optical breath diagnostics normally require molecule-specific spectroscopy. We ask instead how much diagnostic structure survives in the least expensive optical readout available: a single fixed-wavelength diode laser and a dual-axis position-sensing photodiode, giving three channels — back-scattered intensity ( I ) and two beam-position coordinates ( x,y ). Seven calibration classes, comprising five disease-linked breath-metabolite mixtures (disease-linked surrogates) covering established gas concentration ranges (in ppb / ppm), a healthy-air surrogate and an ambient control, were injected at constant mass flow, into a sealed chamber and recorded at 25 kHz, later down sampled to 10 Hz for each run for easing the computational load, over nineteen runs. Detection of any injection is effectively certain within seconds: mean Mahalanobis distances from the ambient cluster are 176 to 447, against a within-cluster mean of 1.6. Concentration is recovered by cubic intensity–concentration calibrations across nine gas channels, with coefficients of determination from 0.966 to 0.997. All seven class centroids separate, and a trajectory-aware nearest-template rule assigns 73.7% of runs correctly on resubstitution. Under leave-one-run-out validation, however, accuracy falls to 52.6% against a chance level of 14.3%, and the beam-deflection channels are shown to be dominated by a common pressure-driven refractive-index gradient rather than by composition - an artefact of the design and architecture of the experiment which can be easily modified to improve accuracy. The three channel readout ( I,x,y ), therefore establishes a validated lower bound for minimal optics, and quantifies precisely what separates that bound from classification-grade breath screening.
SN  - 2045-2322
ER  -