Case report: revision surgery for a fractured femoral stem using an ESOP prosthesis – analysis of the diagnostic work-up, treatment strategy, and long-term outcome

Abstract

Femoral stem fracture following total hip arthroplasty is a rare but serious complication that usually requires removal of both implant fragments and implantation of a longer revision stem. However, this procedure may be associated with substantial bone loss and an increased risk of intraoperative and postoperative complications. A 58-year-old man underwent cementless total hip arthroplasty with a Zweymüller-type stem in 2008. Five years later, the stem fractured. During revision surgery, the proximal fragment was removed, whereas the well-fixed distal fragment could not be safely extracted. It was therefore retained, and only the proximal component of a modular ESOP (anatomical modular cementless femoral stem) short stem was implanted. The postoperative course was uneventful. At 13-year follow-up, the patient remains pain-free, with full hip function, and no radiographic evidence of implant loosening. In carefully selected cases, this technique may represent a valuable alternative to extensive revision surgery.

Related

  1. Atypical spinal epidural lipomatosis: diagnostic strategy and treatment with AUSS technique—A case report
    Ke Deng, Leilei Wu, Long Peng +6
    Frontiers in surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Staged Endodontic Management and Esthetic Rehabilitation of a Fractured Immature Incisor With Failed Endodontic Treatment and Iatrogenic Complications: A Case Report
    Prerna Priya, Abiskar Basnet
    Clinical Case ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  3. Unexpected positive intraoperative culture during supposed aseptic hip revision: Antibiotherapy is an effective and safe treatment. About 50 cases
    Guillaume Auberger, Pierre-Alban Bouché, Thomas Aubert +5
    SICOT-JPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  4. Revision outcomes after failed hip resurfacing arthroplasty vary by failure indication and component strategy: A systematic review
    Srikar Reddy Namireddy, Hariharan Subbiah Ponniah, Milos Brjklac +2
    Journal of experimental orthopaedicsPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  5. Partial Situs Inversus Complicating the Surgical and Diagnostic Course of a Duodenal Switch Revision: A Case Report
    Adelina Balidemaj, Naazpreet Harika, Mohammed Arain
    CureusPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
BibTeX
@article{dutka2026case,
  title = {{Case report: revision surgery for a fractured femoral stem using an ESOP prosthesis – analysis of the diagnostic work-up, treatment strategy, and long-term outcome}},
  author = {Łukasz Dutka and Julian Dutka and Adrian Szczecina and Adam Solarz and Dominik Kostarczyk and Mateusz Bukowczan},
  journal = {Journal of Surgical Case Reports},
  year = {2026},
  month = oct,
  doi = {10.1093/jscr/rjag958},
  url = {https://doi.org/10.1093/jscr/rjag958},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Case report: revision surgery for a fractured femoral stem using an ESOP prosthesis – analysis of the diagnostic work-up, treatment strategy, and long-term outcome
AU  - Łukasz Dutka
AU  - Julian Dutka
AU  - Adrian Szczecina
AU  - Adam Solarz
AU  - Dominik Kostarczyk
AU  - Mateusz Bukowczan
PY  - 2026
DA  - 2026/10/22
JO  - Journal of Surgical Case Reports
DO  - 10.1093/jscr/rjag958
UR  - https://doi.org/10.1093/jscr/rjag958
AB  - Femoral stem fracture following total hip arthroplasty is a rare but serious complication that usually requires removal of both implant fragments and implantation of a longer revision stem. However, this procedure may be associated with substantial bone loss and an increased risk of intraoperative and postoperative complications. A 58-year-old man underwent cementless total hip arthroplasty with a Zweymüller-type stem in 2008. Five years later, the stem fractured. During revision surgery, the proximal fragment was removed, whereas the well-fixed distal fragment could not be safely extracted. It was therefore retained, and only the proximal component of a modular ESOP (anatomical modular cementless femoral stem) short stem was implanted. The postoperative course was uneventful. At 13-year follow-up, the patient remains pain-free, with full hip function, and no radiographic evidence of implant loosening. In carefully selected cases, this technique may represent a valuable alternative to extensive revision surgery.
SN  - 2042-8812
ER  -