Subarachnoid hemorrhage caused by a paradoxical septic embolism from pacemaker lead infection: A case report.
- 1Department of Cardiovascular Medicine, Nephrology, and Neurology, Graduate School of Medicine, University of the Ryukyus, Okinawa, Japan.
- 2Infection Control Team, University of the Ryukyus Hospital, Okinawa, Japan.
Abstract
Subarachnoid hemorrhage resulting from a paradoxical septic embolism associated with right-sided cardiac infection has not been previously reported. An 85-year-old woman with a history of aortic valve replacement and right ventricular pacemaker implantation 7 years earlier presented with sudden-onset left upper limb weakness and a small subarachnoid hemorrhage over the right frontal convexity. Contrast-enhanced computed tomography revealed a small aneurysm in the distal right middle cerebral artery. Transthoracic echocardiography revealed vegetation on the right ventricular pacemaker lead, and blood cultures showed growth of Listeria monocytogenes. Transesophageal echocardiography revealed a patent foramen ovale without evidence of infection in the left cardiac chambers or bioprosthetic aortic valve. The patient was diagnosed with subarachnoid hemorrhage due to the rupture of an infectious intracranial aneurysm, presumably caused by a paradoxical septic embolism originating from the pacemaker lead vegetation. After antibiotic therapy, follow-up transthoracic echocardiography revealed complete resolution of the lead vegetation. To our knowledge, this is the first reported case of subarachnoid hemorrhage resulting from a presumed paradoxical septic embolism associated with a pacemaker lead infection.
Related
- Explainable machine learning–based prediction of postoperative pulmonary infection after aneurysmal subarachnoid hemorrhage clipping and exploratory analysis of enteral nutrition timing: a dual-cohort retrospective study
- From bradyarrhythmia to embolism: A rare case of acute pulmonary embolism immediately after pacemaker implantation.
- Posterior Circulation Stroke From Paradoxical Embolism in a Patient With Patent Foramen Ovale Dislodged During Masturbation.
- Subarachnoid Hemorrhage Following Ischemic Stroke in Vertebrobasilar Dolichoectasia
- A Hemorrhagic Spinal Tumor Presenting as an Intracranial Subarachnoid Hemorrhage
BibTeX
@article{yamashiro2026subarachnoid,
title = {{Subarachnoid hemorrhage caused by a paradoxical septic embolism from pacemaker lead infection: A case report.}},
author = {Takayuki Yamashiro and Hirokuni Sakima and Toshiki Yamashiro and Masashi Nakamatsu and Kenya Kusunose},
journal = {Radiology case reports},
year = {2026},
month = oct,
doi = {10.1016/j.radcr.2026.10.016},
url = {https://europepmc.org/article/MED/42997847},
note = {CC BY},
}
RIS
TY - JOUR
TI - Subarachnoid hemorrhage caused by a paradoxical septic embolism from pacemaker lead infection: A case report.
AU - Takayuki Yamashiro
AU - Hirokuni Sakima
AU - Toshiki Yamashiro
AU - Masashi Nakamatsu
AU - Kenya Kusunose
PY - 2026
DA - 2026/10/29
JO - Radiology case reports
DO - 10.1016/j.radcr.2026.10.016
UR - https://europepmc.org/article/MED/42997847
AB - Subarachnoid hemorrhage resulting from a paradoxical septic embolism associated with right-sided cardiac infection has not been previously reported. An 85-year-old woman with a history of aortic valve replacement and right ventricular pacemaker implantation 7 years earlier presented with sudden-onset left upper limb weakness and a small subarachnoid hemorrhage over the right frontal convexity. Contrast-enhanced computed tomography revealed a small aneurysm in the distal right middle cerebral artery. Transthoracic echocardiography revealed vegetation on the right ventricular pacemaker lead, and blood cultures showed growth of Listeria monocytogenes. Transesophageal echocardiography revealed a patent foramen ovale without evidence of infection in the left cardiac chambers or bioprosthetic aortic valve. The patient was diagnosed with subarachnoid hemorrhage due to the rupture of an infectious intracranial aneurysm, presumably caused by a paradoxical septic embolism originating from the pacemaker lead vegetation. After antibiotic therapy, follow-up transthoracic echocardiography revealed complete resolution of the lead vegetation. To our knowledge, this is the first reported case of subarachnoid hemorrhage resulting from a presumed paradoxical septic embolism associated with a pacemaker lead infection.
SN - 1930-0433
ER -