Abstract
Mechanical aortic valve management during left ventricular assist device (LVAD) support remains challenging. Herein, we report a novel mechanical aortic valve closure technique and its structural outcomes after >6 years of LVAD support. Compared with the conventional sandwich technique, the gap-filler technique required a shorter aortic cross-clamp time (28 vs. 69 min) and demonstrated complete structural integrity at heart explantation without patch dislocation or gross thrombus formation, suggesting superior long-term durability.
Related
- Underlap suturing: a safe closure technique for full-thickness defects using endoscopic hand suturing.
- Novel placement technique of a left ventricular assist device for advanced heart failure with extensive left ventricular thrombus
- OP–103 Unmasking of alcapa following ventricular septal defect closure: a case report
- Modified endocardial linear infarct exclusion technique for congenital left ventricular aneurysm in a neonate: A feasible surgical option
- Long-term outcomes for repair of inferolateral left ventricular pseudoaneurysm via the endocardial exclusion patch technique
BibTeX
@article{shiozaki2026durability,
title = {{Durability of a novel mechanical aortic valve closure technique during left ventricular assist device support: A comparative case report.}},
author = {Yuji Shiozaki and Yuki Ichihara and Saeko Yoshizawa and Satoshi Saito and Hiroshi Niinami},
journal = {JHLT open},
year = {2026},
month = sep,
doi = {10.1016/j.jhlto.2026.100699},
url = {https://europepmc.org/article/MED/42927249},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Durability of a novel mechanical aortic valve closure technique during left ventricular assist device support: A comparative case report.
AU - Yuji Shiozaki
AU - Yuki Ichihara
AU - Saeko Yoshizawa
AU - Satoshi Saito
AU - Hiroshi Niinami
PY - 2026
DA - 2026/09/26
JO - JHLT open
DO - 10.1016/j.jhlto.2026.100699
UR - https://europepmc.org/article/MED/42927249
AB - Mechanical aortic valve management during left ventricular assist device (LVAD) support remains challenging. Herein, we report a novel mechanical aortic valve closure technique and its structural outcomes after >6 years of LVAD support. Compared with the conventional sandwich technique, the gap-filler technique required a shorter aortic cross-clamp time (28 vs. 69 min) and demonstrated complete structural integrity at heart explantation without patch dislocation or gross thrombus formation, suggesting superior long-term durability.
SN - 2950-1334
ER -