Experimental investigation on human thermal responses to static and dynamic ramp temperatures in simulated hot-humid underground environments
- 1State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, School of Mechanics and Civil Engineering, China University of Mining and Technology, Xuzhou 221116, China; Corresponding author.
- 2State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, School of Mechanics and Civil Engineering, China University of Mining and Technology, Xuzhou 221116, China
- 3China Coal Construction Group Corp Ltd, Beijing 102218, China
Abstract
Thermal conditions in underground environments are critical for occupants' safety, health, and productivity. While workers in these settings typically experience dynamic thermal variations, existing research has predominantly focused on static conditions. This study experimentally investigates human physiological and perceptual responses under both static (29, 32 °C) and dynamic ramp-change conditions (26–32/35/38 °C) in a climate chamber. The thermal sensation vote (TSV), thermal comfort vote (TCV), wetness sensation vote (WSV), core temperature (T c ), and mean skin temperature (T sk ) were assessed. Results indicate that under static conditions, these parameters stabilised after 20–30 min due to short-term thermal acclimatisation. Under dynamic conditions, they continued to evolve and exceeded static levels after approximately 40 min. As the ambient temperature increased from 26 to 38 °C, 7.39 % of subjects experienced severe dyspnea, and heart rate and total fluid loss significantly increased by 10.51 bpm and 54.15 g compared with a static 32 °C condition. T sk , TSV, and WSV increased markedly, while TCV demonstrated a declining trend. A hysteresis phenomenon was observed, whereby the average core temperature under dynamic conditions was lower than that under static conditions, which diminished with larger temperature increases. A strong linear correlation was identified among TSV, TCV, T c, and T sk , indicating that the rate of T c acceleration increased when T sk exceeded 35.24 °C. Notably, the core temperature threshold for mild discomfort (TCV>-0.5) under dynamic conditions is 37.19 °C, which is 0.81 °C lower than that under static conditions. The increase rate of T c accelerates significantly from 0.005 °C/min to 0.012 °C/min when T sk exceeds 35.24 °C. These findings provide critical insights for improving workers' thermal comfort in hot-humid underground environments.
Related
- Genuine association or spurious responses? An experimental investigation of the association between cryptocurrency trading and Problem Gambling Severity Index scores
- On-site WBGT at infant height in a childcare facility during peak summer: sun-exposed areas exceed national published values and shaded ground-level environments reach extreme temperatures
- From hypoxia to thrombosis: a hypothesis-driven framework for pulmonary embolism risk in deep underground environments
- Nutritional profiling and pharmacological investigation of Baccaurea motleyana peel and seed through experimental and computational approach
- Physiological responses to 10 days of heart rate–clamped heat acclimation in hot–dry and hot–humid environments
BibTeX
@article{wang2026experimental,
title = {{Experimental investigation on human thermal responses to static and dynamic ramp temperatures in simulated hot-humid underground environments}},
author = {Yijiang Wang and Xingming Wang and Xiaojuan Lai and Wenbo Fan and Chenyu Wan},
journal = {Energy and Built Environment},
year = {2026},
month = oct,
doi = {10.1016/j.enbenv.2026.02.005},
url = {https://doi.org/10.1016/j.enbenv.2026.02.005},
note = {CC BY},
}
RIS
TY - JOUR
TI - Experimental investigation on human thermal responses to static and dynamic ramp temperatures in simulated hot-humid underground environments
AU - Yijiang Wang
AU - Xingming Wang
AU - Xiaojuan Lai
AU - Wenbo Fan
AU - Chenyu Wan
PY - 2026
DA - 2026/10/30
JO - Energy and Built Environment
DO - 10.1016/j.enbenv.2026.02.005
UR - https://doi.org/10.1016/j.enbenv.2026.02.005
AB - Thermal conditions in underground environments are critical for occupants' safety, health, and productivity. While workers in these settings typically experience dynamic thermal variations, existing research has predominantly focused on static conditions. This study experimentally investigates human physiological and perceptual responses under both static (29, 32 °C) and dynamic ramp-change conditions (26–32/35/38 °C) in a climate chamber. The thermal sensation vote (TSV), thermal comfort vote (TCV), wetness sensation vote (WSV), core temperature (T c ), and mean skin temperature (T sk ) were assessed. Results indicate that under static conditions, these parameters stabilised after 20–30 min due to short-term thermal acclimatisation. Under dynamic conditions, they continued to evolve and exceeded static levels after approximately 40 min. As the ambient temperature increased from 26 to 38 °C, 7.39 % of subjects experienced severe dyspnea, and heart rate and total fluid loss significantly increased by 10.51 bpm and 54.15 g compared with a static 32 °C condition. T sk , TSV, and WSV increased markedly, while TCV demonstrated a declining trend. A hysteresis phenomenon was observed, whereby the average core temperature under dynamic conditions was lower than that under static conditions, which diminished with larger temperature increases. A strong linear correlation was identified among TSV, TCV, T c, and T sk , indicating that the rate of T c acceleration increased when T sk exceeded 35.24 °C. Notably, the core temperature threshold for mild discomfort (TCV>-0.5) under dynamic conditions is 37.19 °C, which is 0.81 °C lower than that under static conditions. The increase rate of T c accelerates significantly from 0.005 °C/min to 0.012 °C/min when T sk exceeds 35.24 °C. These findings provide critical insights for improving workers' thermal comfort in hot-humid underground environments.
SN - 2666-1233
ER -