Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 59 min ago
Peer-reviewedCC BY-NC 4.0Multidisciplinary Respiratory Medicine

Pilot study comparing the quality of airway seal in an endotracheal tube with a viscoelastic cuff compared to standard endotracheal tubes

4 affiliations
  1. 1Servicio Vasco de Salud – Osakidetza. Universidad de la Laguna, Tenerife, Spain
  2. 2Departamento de Otorrinolaringología, Cirugía de Cabeza y Cuello, Hospital Nuestra Señora de la Candelaria, Santa Cruz de Tenerife, Canary Islands, Spain
  3. 3Speech and Language Therapist (SLT) Unit, University Hospital Nuestra Señora de Candelaria, Tenerife, Spain
  4. 4Cardiovascular Intensive Care Unit, Rooney Heart Institute, Naples Community Hospital, Naples, Florida, USA

Abstract

Background: Inadequate endotracheal tube (ETT) cuff sealing permits microaspiration of subglottic secretions, a primary driver of ventilator-associated pneumonia (VAP) and perioperative respiratory complications. Both standard cylindrical and specialty tapered cuffs are susceptible to microchannel formation, allowing leakage even at recommended inflation pressures. This pilot study evaluated a novel ETT with a 90-mm self-expanding viscoelastic cuff (V-Cuff®) operating at ambient pressure and compared its sealing performance to standard and specialty ETTs under controlled in vitro conditions.

Methods: Five ETTs of each type – standard cylindrical cuff (Ruschelit®, Teleflex Medical), specialty tapered cuff (Shiley Evac/TaperGuard®, Medtronic), and V-Cuff® (Medis Medical LTD) – were tested in a temperature-controlled (37°C) airway workstation using a 3D-printed tracheal model with 5 cmH2O positive end-expiratory pressure (PEEP) applied uniformly to the lower segment in all tests. Tests included upper and lower pressure threshold assessments (UPTA and LPTA, respectively), and simulations of swallowing (80 mmHg, 2 seconds) and coughing (125 mmHg, 3 seconds). Statistical analysis used the Mann-Whitney U test for continuous outcomes and Fisher’s Exact Test for categorical outcomes.

Results: Under uniform 5 cmH2O PEEP conditions, the standard ETT demonstrated immediate leakage at 0 mmHg on UPTA; the specialty ETT achieved a seal under PEEP, tolerating supracuff pressures exceeding 90 mmHg. The V-Cuff® maintained complete seal integrity from 0 mmHg onwards under all UPTA conditions. Both the specialty ETT and V-Cuff® tolerated supracuff pressures exceeding 90 mmHg on UPTA (p<0.001 vs. standard; Fisher’s Exact Test, exact p<0.001). On LPTA, air leak occurred at a mean of 5 ± 0.71 mmHg (standard) and 12 ± 1.22 mmHg (specialty); the V-Cuff® showed no leakage at pressures exceeding 90 mmHg (Mann-Whitney U, p=0.008 vs. standard; p=0.008 vs. specialty). All standard and specialty ETTs leaked during simulated swallowing and coughing (5/5); the V-Cuff® demonstrated no leakage under either condition (0/5; Fisher’s Exact Test, exact p=0.008).

Conclusions: In this exploratory pilot in vitro study, the V-Cuff® ETT demonstrated superior airway sealing under all static and dynamic conditions compared to standard and tapered-cuff ETTs, with no leakage events across any test. These preliminary findings suggest that the improved seal may reduce tracheal soiling and airway contamination; whether this translates to a reduction in aspiration-related pulmonary complications requires prospective clinical validation.

Related

  1. An Alternative Approach to Adult One-Lung Ventilation Using a Standard Single-Lumen Endotracheal Tube
    Mahesh S Desilva, Dineth L Senanayake
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Airway ultrasound versus capnography to confirm endotracheal intubation: protocol for a systematic review and meta-analysis
    Manjush Karthika, Chris Sara Mathew, Ashraf Alzaabi +3
    Systematic ReviewsPeer-reviewedCC BY-NC-ND 4.0Surgery & anaesthesiaCrossref
  3. Trans-cuff budesonide delivery and its effects on endotracheal intubation-induced subglottic injury
    Yi Zou, Qing Hu, Xiao Yan +6
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Efficacy and Safety of Etomidate Versus Ketamine for Endotracheal Intubation in Critically Ill Patients: A Systematic Review and Meta-Analysis
    Zeeshan Umar, Tayyamn Tahseen, Aalyan Shafi +8
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Airway Obstruction With Severe Hypoxemia Caused by Malformation of an Endotracheal Tube Cuff: A Case Report
    Xin Li, Yuwen Chen, Dan Zhou
    Clinical Case ReportsPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
BibTeX
@article{fernandez2026pilot,
  title = {{Pilot study comparing the quality of airway seal in an endotracheal tube with a viscoelastic cuff compared to standard endotracheal tubes}},
  author = {Pedro Alejandro Bravo Fernández and Daniel A. Cueva Nieves and Nieves Leon-Gomez and Juan José Artazkoz del Toro and Ricardo Martinez-Ruiz},
  journal = {Multidisciplinary Respiratory Medicine},
  year = {2026},
  month = sep,
  doi = {10.5826/mrm.2026.1094},
  url = {https://doi.org/10.5826/mrm.2026.1094},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Pilot study comparing the quality of airway seal in an endotracheal tube with a viscoelastic cuff compared to standard endotracheal tubes
AU  - Pedro Alejandro Bravo Fernández
AU  - Daniel A. Cueva Nieves
AU  - Nieves Leon-Gomez
AU  - Juan José Artazkoz del Toro
AU  - Ricardo Martinez-Ruiz
PY  - 2026
DA  - 2026/09/02
JO  - Multidisciplinary Respiratory Medicine
DO  - 10.5826/mrm.2026.1094
UR  - https://doi.org/10.5826/mrm.2026.1094
AB  - Background: Inadequate endotracheal tube (ETT) cuff sealing permits microaspiration of subglottic secretions, a primary driver of ventilator-associated pneumonia (VAP) and perioperative respiratory complications. Both standard cylindrical and specialty tapered cuffs are susceptible to microchannel formation, allowing leakage even at recommended inflation pressures. This pilot study evaluated a novel ETT with a 90-mm self-expanding viscoelastic cuff (V-Cuff®) operating at ambient pressure and compared its sealing performance to standard and specialty ETTs under controlled in vitro conditions.  Methods: Five ETTs of each type – standard cylindrical cuff (Ruschelit®, Teleflex Medical), specialty tapered cuff (Shiley Evac/TaperGuard®, Medtronic), and V-Cuff® (Medis Medical LTD) – were tested in a temperature-controlled (37°C) airway workstation using a 3D-printed tracheal model with 5 cmH2O positive end-expiratory pressure (PEEP) applied uniformly to the lower segment in all tests. Tests included upper and lower pressure threshold assessments (UPTA and LPTA, respectively), and simulations of swallowing (80 mmHg, 2 seconds) and coughing (125 mmHg, 3 seconds). Statistical analysis used the Mann-Whitney U test for continuous outcomes and Fisher’s Exact Test for categorical outcomes.  Results: Under uniform 5 cmH2O PEEP conditions, the standard ETT demonstrated immediate leakage at 0 mmHg on UPTA; the specialty ETT achieved a seal under PEEP, tolerating supracuff pressures exceeding 90 mmHg. The V-Cuff® maintained complete seal integrity from 0 mmHg onwards under all UPTA conditions. Both the specialty ETT and V-Cuff® tolerated supracuff pressures exceeding 90 mmHg on UPTA (p<0.001 vs. standard; Fisher’s Exact Test, exact p<0.001). On LPTA, air leak occurred at a mean of 5 ± 0.71 mmHg (standard) and 12 ± 1.22 mmHg (specialty); the V-Cuff® showed no leakage at pressures exceeding 90 mmHg (Mann-Whitney U, p=0.008 vs. standard; p=0.008 vs. specialty). All standard and specialty ETTs leaked during simulated swallowing and coughing (5/5); the V-Cuff® demonstrated no leakage under either condition (0/5; Fisher’s Exact Test, exact p=0.008).  Conclusions: In this exploratory pilot in vitro study, the V-Cuff® ETT demonstrated superior airway sealing under all static and dynamic conditions compared to standard and tapered-cuff ETTs, with no leakage events across any test. These preliminary findings suggest that the improved seal may reduce tracheal soiling and airway contamination; whether this translates to a reduction in aspiration-related pulmonary complications requires prospective clinical validation.
SN  - 1828-695X
SN  - 2049-6958
ER  -